Non-encapsulated H-class Dry-type Power Transformers 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA

  • Non-encapsulated H-class Dry-type Power Transformers 800kVA 1000kVA 1250kVA 1600kVA 2000kVA 2500kVA

Key attributes

Brand Vziman
Model NO. Non-encapsulated H-class Dry-type Power Transformers 800KVA 1000KVA 1250KVA 1600KVA 2000KVA 2500KVA
Rated capacity 2500kVA
Voltage grade 10KV
Series SGB

Product descriptions from the supplier

Description

Description:
The SG(B)10 series non-encapsulated H-class dry-type power transformers integrate German (MORA) dry-type transformer process technology, ensuring full compliance with fireproof, waterproof, and environmental protection standards. Engineered as ideal solutions for distribution systems, they excel in safety-critical applications, including subways, shipbuilding, mining, chemical industries, power utilities, and personnel-dense buildings, as well as environments with special safety requirements.

Feature

  • Maintenance-free Design: The non-encapsulated windings allow direct visual inspection, eliminating the need for preventive tests. This extends the maintenance cycle to 5 years and reduces the full life-cycle cost by 30%.

  • Intelligent Monitoring Integration: Equipped with built-in winding temperature sensors and RS485 communication interfaces, it supports remote monitoring and early warning. The fault response time is shortened to seconds, significantly reducing operational and maintenance costs.

  • Superior Insulation and Heat Dissipation Performance: Adopts H-class insulation materials (temperature resistance up to 180℃), combined with non-encapsulated open-winding design, which enhances heat dissipation efficiency by 30%. It can stably operate under 150% rated capacity overload, perfectly suitable for high-load fluctuation working conditions.


Model and Meaning:

企业微信截图_17230768291792.png

Parameter:


image.png


Notes: The Dimension and weight will be changed according to the requirements.


What is an Unencapsulated Class H Dry-Type Power Transformer?

Basic Definitions:

  • Non-encapsulated: It means that the coils of the transformer are not subjected to the traditional encapsulation treatment but are directly exposed to the air. This design can improve the heat dissipation efficiency and extend the service life.

  • H-Class Insulation: H-Class insulation materials refer to those insulation materials that can withstand a maximum temperature of 180°C. They possess excellent heat resistance and electrical properties.

Structural Characteristics:

  • Coil Structure: The non-encapsulated structure is adopted, with the coils being directly exposed to the air, which is beneficial for heat dissipation.

  • Insulation Materials: H-Class insulation materials such as NOMEX paper and fiberglass are used, featuring excellent heat resistance and electrical properties.

  • Iron Core: It is usually made of laminated high-quality silicon steel sheets, with the characteristics of low loss and low noise.

  • Cooling Methods: Generally, natural air cooling (AN) or forced air cooling (AF) is employed. The appropriate cooling method is selected according to specific application requirements.


Documentation Resource Library
Restricted
Vziman IEC/ ANSI Dry-Type Power transformer selection catalog
Catalogue
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff:
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    ​1. Challenges in High-Voltage Power Systems​1.1 High-voltage power systems, as the core of power transmission, face critical challenges:​Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements.​Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages.​Poor Environmental Ada
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 ​Grid Frequency Fluctuations and Stability Issues​The intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within m
    05/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.