lae frekwensie aanlyn UPS kragvoorsiening (3-fase invoer 1-fase uitvoer)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Sleutelkenmerke

Handelmerk Switchgear parts
Modelnommer lae frekwensie aanlyn UPS kragvoorsiening (3-fase invoer 1-fase uitvoer)
Gedraaide frekwensie 50/60Hz
Uitvoer-spanning 405VDC/220VDC
Ingangspanning 380V
Kapasiteit 15kVA
Reeks HBD

Produkbeskrywings van die voorsienier

Beskrywing

Produkteienskappe

Intelligente digitale beheertechnologie
Deur Intel-hoëspoed-mikrobestuurders en programmeerbare logikaapparate te gebruik, word sirkusbeheer, parameterinstelling, bedryfsbestuur, gevorderde selftoetsing- en selfopsporingfunksies bereik. Dit kan selftoetsing en foutanalise uitvoer op al die onafhanklike sirkuskonneksies op die sirkusplaat. Jy kan volledig vertrou op die digitaal omskepte sinusgolfspanning en die nuwe oplossing vir perfekte bedryf om jou werklike behoeftes te bevredig.
Effektiewe IGBT (geïsoleerde hekgesele transistor) invertertegnologie
IGBT het uitsonderlike hoëspoedskakelkenmerke; Dit het werkskenmerke van hoë spannings en hoë stroom; Deur spanningsaangedrewe te gebruik, is slegs 'n klein beheerspanning nodig. Die sesde generasie IGBT het 'n laer versteuringspanningsval, hoër inverterdoeltreffendheid en hoër betroubaarheid.
Uitsonderlike belkenmerke
Voldoen volledig aan die oorgang van 0 tot 100% bel sonder om na 'n omweg oor te skakel, en beskerm stabiele en betroubare uitset.
Gemenskaplike groot skerm LCD-weergawe in beide Chinees en Engels
Die groot skerm wys 'n menu in beide Chinees en Engels, met 'n duidelike vloeidiagram wat die operasionele status wys, wat die buigsame implementering van mens-masjien-gesprekfunksies toelaat. Intuïtiewe LED-statusaanwysing, werkstroomstyl-statusaanwysing, duidelik op 'n oogopslag.
Hoë prestasie dinamiese kenmerke
Verskeie terugvoerbeheer soos oombliklike beheer en effektiewe waarde word aangewend om hoë dinamiese regulerings en verminderde uitsetspanningsversteuring te bereik.
Volledige beskermingsfunksie
Verskeie stelselbeskermings- en waarskuwingsfunksies, insluitend invoer/uitvoer oorspanningsbeskerming, invoerslagbeskerming, fasevolgordebeskerming, batterylagespanningsbeskerming, uitvoeroorspanningsbeskerming, en hoë temperatuurbeskerming.
Intelligente batteriebestuur
Intelligente batterielading: Pas outomaties die ladingparameters van die batterie aan volgens die gebruiker se batteriekonfigurasie, en voer gelykmatige en dreunladingomskakeling, temperatuurkompensasie lading en aflading bestuur op die batterie uit volgens die kragvoorsieningsomgewing. Verleng die leeftyd van die batterie en verminder die belasting van bestuurders.
Gebruik van 'n 6-puls (opsioneel 12 puls) rektifiserlaadertjie terwyl 'n invoerharmoniese filter bygevoeg word
Druk effektief invoerharmoniese besoedeling, verbeter die invoerkragfaktor van UPS-kragvoorsiening, en verminder invoerharmoniese stroom.
intelligente monitoring
RS232 en RS485 kommunikasieports maak werklik multi-doel kommunikasie en afstandbediening moontlik. Opsionele SNMP-kaart vir afstandbediening en netwerkbestuur; Opsionele droëkontakinterface, deur middel van pasiewe kontakte om die status van UPS te moniteer.

Toepassingsveld
Geskik vir industrieë soos finansies, telekomunikasie, aandele, belasting, vervoer, versekering, regering, gebou-verligting, padverkeersverligting, elektrisiteit, en industriële en mynbouondernemings.

Tegniese spesifikasies

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Let op: Die model met ingeboude batterij en spesifieke volsspanningsvereistes kan na die werklike situasie van die gebruiker aangepas word, en 'n aparte prysopsomming sal verskaf word.

FAQ vir
Q: Hoe om algemene foute van hierdie UPS te hanteer?
A:

Q: Wat is die kernfunksie en werkprinsipe van 'n 3-fase invoer 1-fase uitvoer lae frekwensie aanlyn UPS?
A:

Sy kernfunksie is om 3-fase hooflynvermoë oor te skakel na stabiele 1-fase vermoë, wat ononderbroke, suiwer vermoë verskaf vir enkel-fase kritiese belastings terwyl dit hooflynprobleme soos spanningfluktuasies, harmoniese interferensie en vermoë-uitval oplos. Werkprinsipe: Aanvaar dubbele omskakeling (AC-DC-AC) + lae-frekwensie transformatorontwerp. Wanneer die hooflyn normaal is, word 3-fase AC oorgeskakel na DC om die batterye te laai, dan word DC oorgeskakel na 1-fase suiwer sinusgolf AC vir belastingverskaffing; wanneer die hooflyn uitval, switsoor na batterievermoë met 0ms oorskakeltyd,

Ken u lewerancier
Online winkel
Punte tydlewering
Reaksietyd
100.0%
≤4h
Bedryfsomsig
Werkplek: 1000m² Totale personeel: Hoogste Jaarlikse Uitvoer (VSA): 300000000
Werkplek: 1000m²
Totale personeel:
Hoogste Jaarlikse Uitvoer (VSA): 300000000
Dienste
Geselsaakstype: Verkope
Hoofdskategorieë: Toerustingkomponente/Toerusting vir inspeksie/Hoëspanningstoerusting/Laagspanningstoerusting/Meetinstrumente/Produksie-toerusting/Elektriese goudartikels
Levenslange garantiebeheerder
Heel Lewensorg Sorg Dienste vir toerustingverskaffing, gebruik, instandhouding en naverkoop, om veilige bedryf van elektriese toerusting, deurlopende beheer en sorgvrye elektrisiteitsverbruik te verseker
Die toerustingverskaffer het platformkwalifikasiesertifisering en tegniese evaluering deurgegaan, wat aan die bron nakoming, professionele standaarde en betroubaarheid verseker.

Verwante produkte

Verwante Kennis

  • Hoofdtransformator-ongelukke en liggasbedryfsprobleme
    1. Ongelukverslag (19 Maart 2019)Op 19 Maart 2019 om 16:13 het die moniteringagtergrond 'n liggasaksie van Hooftransformator nr. 3 gerapporteer. In ooreenstemming met die Reguitlyne vir die Bedryf van Kragtransformatore (DL/T572-2010), het bedryf en onderhoud (B&O) personeel die toestand van Hooftransformator nr. 3 ter plaatse geïnspekteer.Bevestiging ter plaatse: Die WBH nie-elektriese beskermingspaneel van Hooftransformator nr. 3 het 'n Ligfas B gasaksie van die transformatorliggaam gerapp
    02/05/2026
  • Fouten en Handhaving van Enkelefasig Gronding in 10kV Verspreidingslyne
    Kenmerke en opsporingsapparatuur vir enkelfase-grondsluitingsfoute1. Kenmerke van enkelfase-grondsluitingsfouteSentrale waarskuwingsseine:Die waarskuwingklokkie lui, en die aanwyslamp met die etiket “Grondsluiting op [X] kV-busafdeling [Y]” gaan aan. In stelsels met ’n Petersen-kolf (boogonderdrukkingkolf) wat die neutraalpunt grond, gaan die “Petersen-kolf in werking”-aanwyslamp ook aan.Aanwysings van isolasie-toepassingsvoltmeter:Die spanning van die gefouteerde fase da
    01/30/2026
  • Neutralpunt-grondingbedryfmodus vir 110kV~220kV kragroostertransformasies
    Die inligtingsstruktuur van die nulpunt-grondingoperasie vir 110kV~220kV-kragsentrafo's moet aan die isolasieverdraagskap van die transformernulpunte voldoen, en dit moet ook probeer om die nulvolgordeimpedansie van die transformators basis onveranderd te hou, terwyl daar verseker word dat die nulvolgorde-komplekse impedansie by enige kortsluitpunt in die stelsel nie drie keer die positiewe volgorde-komplekse impedansie oorskry nie.Vir 220kV en 110kV-transformers in nuwe konstruksie- en tegnolog
    01/29/2026
  • Waarom gebruik substasies stene grondstof kiepe en verpletterde rots?
    Waarom gebruik substasies stene, grond, kiepsteentjies en verpletterde rots?In substasies vereis toerusting soos krag- en verspreidingstransformateurs, oordraaglyne, spanningstransformateurs, stroomtransformateurs en afsluiters alle aarding. Behalwe aarding, gaan ons nou in diepte in op die rede waarom grond en verpletterde steen algemeen in substasies gebruik word. Alhoewel hulle gewoon voorkom, speel hierdie stene 'n kritieke veiligheids- en funksionele rol.In die ontwerp van substaasie-aardin
    01/29/2026
  • Waarom moet die transformatorkern slegs by een punt aangesluit word? Is nie meerdere punte van aansluiting betroubaarder nie
    Waarom moet die transformator kern aan die grond verbonden word?Tydens bedryf is die transformator kern, saam met die metalstrukture, dele en komponente wat die kern en windings vasmaak, almal in 'n sterk elektriese veld geplaas. Onder die invloed van hierdie elektriese veld verkry hulle 'n relatief hoë potensiaal ten opsigte van die grond. As die kern nie aan die grond verbonden word nie, sal daar 'n potensiaalverskil tussen die kern en die aangeklampde strukture en tank bestaan, wat tot onafha
    01/29/2026
  • Verstaan van Transformer Neutrale Aarding
    I. Wat is 'n Neutrale Punt?In transformateurs en generators is die neutrale punt 'n spesifieke punt in die wonding waar die absolute spanning tussen hierdie punt en elke buite terminal gelyk is. In die diagram hieronder stel puntOdie neutrale punt voor.II. Waarom Moet die Neutrale Punt Aangesluit Word?Die elektriese verbindingsmetode tussen die neutrale punt en die aarde in 'n driefase AC kragstelsel staan bekend as dieneutrale aansluitingmetode. Hierdie aansluitingmetode beïnvloed direk:Die vei
    01/29/2026
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind. Kry Praatskaart Nou
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind.
Kry Praatskaart Nou
Stuur navraag
+86
Klik om lêer op te laai
Laai af
Kry die IEE-Business-toepassing
Gebruik die IEE-Business app om toerusting te vind kry oplossings verbind met kenners en neem deel aan bedryfsamenwerking waar en wanneer ook al volledig ondersteunend van jou kragprojekte en besigheidsgroei