niskofrekventni on-line UPS napajanje (3fazni ulaz 1fazni izlaz)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Ključne karakteristike

Бренд Switchgear parts
Број модела niskofrekventni on-line UPS napajanje (3fazni ulaz 1fazni izlaz)
Nominalna frekvencija 50/60Hz
Izlazno napona 405VDC/220VDC
Ulazna naponska razina 380V
Kapacitet 15kVA
Серија HBD

Opisi proizvoda od strane dobavljača

Opis

Funkcije proizvoda

Inteligentna digitalna kontrolna tehnologija
Korišćenje visokobrzih mikrokontrolera Intela i programabilnih logičkih uređaja za ostvarivanje kontrole kola, podešavanja parametara, upravljanja operacijama, naprednih samoprobe i samodiagnostike. Omogućava samodiagnozu i analizu grešaka na svim nezavisnim vezama na ploči. Potpuno možete vjerovati u transformisan sinusni val naponske talase i novom rešenju za savršeno funkcionisanje kako biste zadovoljili vaše stvarne potrebe.
Efikasna IGBT (izolovani dvopolni tranzistor) inverzorska tehnologija
IGBT ima odlične karakteristike brzog prekida; Imaju radne karakteristike visokog napon i velikog toka; Korišćenjem pogonske napona, potrebna je samo mala snaga za upravljanje. Šest generacija IGBT-a ima niže zasićenje pad napona, veću efikasnost inverzora i veću pouzdanost.
Izuzetne karakteristike opterećenja
Potpuno zadovoljava prijelaz od 0 do 100% opterećenja bez prebacivanja na bypass, čime se osigurava stabilan i pouzdan izlaz.
Humanizirani veliki LCD ekran na kineskom i engleskom jeziku
Veliki ekran prikazuje meni na kineskom i engleskom jeziku, sa jasnom tokom dijagrama koji pokazuje stanje rada, omogućavajući fleksibilnu implementaciju funkcija ljudski-mašinske komunikacije. Intuitivna LED indikacija stanja, tokom stilskog prikaza stanja, jasno na prvi pogled.
Visoko performantne dinamičke karakteristike
Usvajaju se višestruki povratni kontrolni sistemi kao što su trenutna kontrola i efektivna vrijednost kako bi se dostigla visoka dinamička regulacija i smanjenje distorzije izlaznog napon.
Kompletna funkcija zaštite
Višestruka sistem zaštitna i alarmna funkcija, uključujući zaštitu od preopterećenja ulaza/izlaza, zaštitu od talasnog udara na ulazu, zaštitu faze, zaštitu od niskog napon baterije, zaštitu od preopterećenja izlaza, i zaštitu od visoke temperature.
Inteligentno upravljanje baterijama
Inteligentno punjenje baterija: Automatsko prilagođavanje parametara punjenja baterije prema konfiguraciji baterije korisnika, i izvršavanje ravnotežnog i plivačkog punjenja, te upravljanje punjenjem i ispunjenjem baterije uz ovisnost o okruženju snabdevanja. Proširuje životnu vijek baterije i smanjuje teret administratora.
Korišćenje šestimpulsne (opciono dvanastaimpulsne) pravodnog punjača dok se dodaje filter za harmoničku polutanac na ulazu
Eficascno suzbijanje harmonijske zagađenosti na ulazu, poboljšanje faktora snage UPS snabdevanja, i smanjenje harmonijskih struja na ulazu.
inteligentno nadziranje
RS232 i RS485 komunikacijski porti zaista omogućavaju multi-održive komunikacije i daljinski nadzor. Opciona SNMP kartica za daljinski nadzor i upravljanje mrežom; Opcioni sučelni kontakti, koristi se pasivni kontakti za nadzor stanja UPS.

Područje primene
Pogodno za industrije kao što su finansije, telekomunikacije, berza, porezi, promet, osiguranje, vlade, zgrade, osvjetljenje cesta, električna energija, i industrijske i rudarske poduzeća.

Tehnički specifikacije

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Napomena: Model sa ugrađenim baterijom i posebnim zahtevima za napona može biti prilagođen prema stvarnoj situaciji korisnika, a posebna ponuda će biti pružena.

ЧПП за
Q: Kako rukovati najčešćim greškama ovog UPS-a?
A:

① Сигнал преврата: Искључите несавезне једнофазне опреме, или замените са UPS веће капацности; ② Сигнал губије фазе: Проверите проводњу за три фазе, поправите рутле или одвојене кабеле; ③ Сигнал ниске напоне батерије: Константно наелектришите током 12 сати, замените старе батерије ако сигнал претраје; ④ Неправилан излазни напон: Проверите излазну проводњу, ресетирајте UPS (искључите струју и поново покрените после 5 минута); ⑤ Преовршено трансформатора: Одмах прекините коришћење, проверите вентилацију и терет, контактирајте послепродажну подршку за одржавање.

Q: Koja je osnovna funkcija i način rada niskofrekventnog UPS-a sa 3-faznim ulazom i 1-faznim izlazom u on-line režimu?
A:

Jezgra funkcija je da pretvara trofazni mrežni struju u stabilnu jednofaznu struju, obezbeđujući neprekidnu, čistu struju za kritične jednofazne opterećenja dok se rešavaju problemi sa mrežom kao što su fluktuacije napona, harmonijska interferencija i prekid snabdevanja. Način rada: Uvođenje dvostruke konverzije (AC-DC-AC) + nizko-frekventni transformator dizajn. Kada je mreža normalna, 3-fazni AC se pretvara u DC kako bi se punila baterija, zatim se DC pretvara u 1-fazni čisti sinusni talas AC za snabdevanje opterećenja; kada mreža padne, prebacuje se na baterijsku struju sa vremenom prebacivanja od 0ms,

Upoznajte svog dobavljača
Online prodavnica
Stopa na vreme dostave
Vreme odgovora
100.0%
≤4h
Pregled kompanije
Radno mesto: 1000m² Ukupan broj zaposlenih: Najveći godišnji izvoz (USD): 300000000
Radno mesto: 1000m²
Ukupan broj zaposlenih:
Najveći godišnji izvoz (USD): 300000000
Услуге
Vrsta poslovanja: Продаја
Glavne kategorije: Dodaci za uređaje/Oprezna oprema/Visoki napon aparati/Niskonaponski uređaji/мерање инструменти/Proizvodno opreme/Električni pribor
Menadžer doživotne garancije
Услуге менаџмента бриге у току целог животног циклуса за набавку, коришћење, одржавање и сервис по продаји, како би се осигурала безбедна експлоатација електричне опреме, стална контрола и непрекидно коришћење електричне енергије
Добављач опреме је положио сертификацију квалификација платформе и техничку процену, чиме се осигурава усклађеност, стручност и поузданост од извора

Povezani proizvodi

Povezana znanja

  • Glavne transformatorne nesreće i problemi sa radom na svetlostima plinova
    1. Zapisnik o nesreći (19. mart 2019)Dana 19. marta 2019. u 16:13 sati, nadzorna ploča je izveštavala o delovanju lege plinove na glavnom transformatoru broj 3. U skladu sa Pravilnikom o eksploataciji transformatora napona (DL/T572-2010), osoblje za održavanje i rad (O&M) proverilo je stanje na mestu glavnog transformatora broj 3.Potvrđeno na mestu: Panele WBH neelektrične zaštite glavnog transformatora broj 3 su izveštavale o delovanju lege plinove faze B tela transformatora, a resetovanje
    02/05/2026
  • Kvarovi i obrada jednofaznog zemljenja na distribucijskim linijama od 10kV
    Карактеристике и уређаји за откривање једнофазних земљних кратких спојева1. Карактеристике једнофазних земљних кратких спојеваЦентрални алармски сигнали:Звонце за упозорење звучи, а индикаторска лампица означена „Земљни кратки спој на [X] кВ шинском одељку [Y]“ се укључује. У системима са земљним везивањем нулте тачке преко Петерсенове калемске спирале (калем за гашење лука), такође се укључује индикатор „Петерсенова калемска спирала у раду“.Показивања волтметра за надзор изолације:Напон погођен
    01/30/2026
  • Neutralni način operacije zemljanja za transformere mreže od 110kV~220kV
    Način povezivanja neutralne tačke na transformatorima mreže od 110kV do 220kV treba da zadovolji zahteve izolacije neutralnih tačaka transformatora, i treba da se nastoji da se nula-sequens impedansa podstaničnih stanica održi gotovo nepromenjena, dok se osigurava da nula-sequens kompletan impedans u bilo kojoj tački prekidnice sistema ne premaši tri puta pozitivno-sequens kompletan impedans.Neutralni načini zemljanja novih i tehnički unapređenih transformatora od 220kV i 110kV treba strogo da s
    01/29/2026
  • Zašto podstanci koriste kamenje šljunku mrvlje i drobljen kamen?
    Zašto se u podstanicama koriste kamenje, šljunka, kamenčići i drobljeni kamen?U podstanicama, oprema poput transformatora snage i distribucije, prenosnih linija, transformatora napona, transformatora struje i prekidača za odvajanje svi zahtevaju zemljanje. Osim zemljanja, sad će se detaljno istražiti zašto su šljunke i drobljeni kamen često korišćeni u podstanicama. Iako izgledaju obično, ovi kamenji igraju ključnu ulogu u pitanju bezbednosti i funkcionalnosti.U dizajnu zemljanja podstanica - po
    01/29/2026
  • Zašto se jezgra transformatora mora zemljiti samo na jednoj tački Nije višetačka zemlja pouzdanija
    Zašto se jezgra transformatora mora zemljiti?Tokom rada, jezgra transformatora, zajedno sa metalnim konstrukcijama, delovima i komponentama koje fiksiraju jezgru i navojnice, nalazi se u jakom električnom polju. Pod uticajem ovog električnog polja, oni stječu relativno visok potencijal u odnosu na zemlju. Ako se jezgra ne zemlji, postoji će razlika potencijala između jezgre i zemljenih klampnih konstrukcija i rezervoara, što može dovesti do prekidnog iscrpljivanja.Dodatno, tokom rada, jako magne
    01/29/2026
  • Razumevanje neutralne zaklopnje transformatora
    I. Šta je neutralna tačka?U transformatorima i generatorima, neutralna tačka je specifična tačka u vijku gde je apsolutno napona između ove tačke i svakog spoljnog terminala jednako. U sledećem dijagramu, tačkaOpredstavlja neutralnu tačku.II. Zašto treba zemljiti neutralnu tačku?Električni način povezivanja neutralne tačke i zemlje u trofaznom AC sistemu snabdjevanja električnom energijom naziva semetod zemljitve neutralne tačke. Ova metoda zemljitve direktno utiče na:Sigurnost, pouzdanost i eko
    01/29/2026
Još uvek niste pronašli odgovarajućeg dobavljača? Neka verifikovani dobavljači dođu do vas. Dobijte ponudu sada
Još uvek niste pronašli odgovarajućeg dobavljača? Neka verifikovani dobavljači dođu do vas.
Dobijte ponudu sada
Pošalji upit
+86
Кликните да отпремите фајл
Преузми
Preuzmi IEE Business aplikaciju
Koristite IEE-Business aplikaciju za pronalaženje opreme dobijanje rešenja povezivanje sa stručnjacima i učešće u industrijskoj saradnji bilo kada i bilo gde potpuno podržavajući razvoj vaših projekata i poslovanja u energetskom sektoru