frequens parva in linea UPS alimentatio (3 phasus introitus 1 phasus exitus)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Attributa principalia

Marca Switchgear parts
Numerus Modeli frequens parva in linea UPS alimentatio (3 phasus introitus 1 phasus exitus)
Frequenta nominata 50/60Hz
Voltus egressus 405VDC/220VDC
Tensio ingressus 380V
Capacitas 15kVA
Series HBD

Descriptiones productorum a fornitori

Descriptio

Characteristica Producti

Technologia controlis digitalis intelligentis
Usus microcontrollerum celerium Intel et dispositivorum logicae programmabilis ad effectum controlis circuituum, positionis parametrorum, administrationis operationis, functionum autotestis et autodetectionis superiorum, potest autotestificare et analysin defectuum in omnibus connectionibus circuituum independentibus in tabula circuituum perficere. Potestis sine dubio confidere in tensio sinusoidalis digitaliter transformata et nova solutio pro operatione perfecta ad necessitates vestras reales satisfaciendas.
Technologia inverteris IGBT (Insulated Gate Bipolar Transistor) efficientis
IGBT habet excellentes characteres commutationis celeris; habet characteres operativos sub alto tenso et magno fluo; usus est drive tensus, requiritur tantum modicum potentia controlis. Sexta generatio IGBT habet diminutum voltu saturato, altiorem efficaciam inverteris, et altiorem fiduciam.
Superiores characteres oneris

Plene satisfacit transitionem ab 0 ad 100% oneris absque commutatione ad bypass, et protegit output stabilis et fidelis.
Display LCD grande humanitatis utraque lingua Sinica et Anglica
Display grande exhibet menu utraque lingua Sinica et Anglica, cum diagrammate fluxus claro ostendente statum operationis, permittens flexibilem implementationem functionum dialogi hominis-machinae. Indicatio status LED intuitiva, indicatio status stili workflow, clara uno intuitu.
Altae performance characteres dynamicae
Adoptantur plures feedback controles sicut controlis instantaneus et valorem effectivum ad altam regulationem dynamicam perficiendam et distortionem tensio output minuendam.
Functio protectionis completa
Plures functiones protectionis et alarmatis systematis, inter quas protectionem overvoltage input/output, protectionem surga input, protectionem phase sequence, protectionem low voltage battery, protectionem overvoltage output, et protectionem high temperature.
Gestio battery intelligentis
Cursus charging battery intelligentis: Automatice adiustat parameters charging battery secundum configurationem battery usatoris, et facit conversionem equalizationis et float charging, compensationem temperature charging et discharging management super battery secundum environmentem supply power. Extendit longevitatem battery et minuit onus administrativum.
Adoptans rectifier charger 6-pulsus (optionalis 12 pulsus) addendo filter harmonicum input
Efficienter suppressit pollutionem harmonica input, meliorat factorem potentiae input UPS power supply, et minuit currentem harmonicum input.
monitoring intelligentis
Portae communicationis RS232 et RS485 vere permittunt communicationem multipropositum et monitoringem remotam. Card SNMP optionalis pro monitoringe remota et gestione network; interficies contact dry optionalis, usura contactis passivi ad statum UPS monitorandum.

Campus applicationis
Conveniens pro industriis sicut financia, telecommunicationes, securities, taxatio, transportatio, insurantia, gubernatio, illuminatione aedificiorum, illuminatione viarum, electricitas, et industriae et minerae.

Specificationes technicae

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Nota: Exemplar cum bateria incorporata et requisitis voltaticis specialibus potest ad normam conditionis realis usatoris adaptari, et pro eo separatim praebetur pretium.

FAQ pro
Q: Quomodo communia huius UPS vitia tractentur
A:

Q: Quae est functio et principium operativum UPS on-line bassa frequentia cum 3-phasalis ingrediens et 1-phasalis exitus?
A:

Functio eius principalis est convertendi potentiam tricorporalem in stabilem potentiam uniphasicam, praebendo potestatem continuam et puram pro oneribus criticis uniphasicis, dum solvit problemata potestatis tali qualia sunt fluctuationes tensionis, interferentia harmonica, et interrupcio potestatis. Principium operativum: adhibet conversionem duplicem (AC-DC-AC) + designum transformatoris bassifrequenticum. Quando potestas mains normalis est, AC tricorporalis convertitur in DC ad bateriam caricae; deinde DC convertitur in AC uniphasicam puram sinusoidalem pro suppleamento oneris; quando potestas mains deficit, commutat ad potestatem bateriae cum tempore transitorio 0ms,

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe