Modularis UPS ininterrupta alimentatio electrica

  • Modular UPS emergency power supply

Attributa principalia

Marca Switchgear parts
Numerus Modeli Modularis UPS ininterrupta alimentatio electrica
Frequenta nominata 50/60Hz
Voltus egressus 380/400/415VAC
Tensio ingressus 380/400/415VAC
Capacitas 300kVA
Series HBM

Descriptiones productorum a fornitori

Descriptio

HBM50-600KW est novus generatio triplex in triplex modulare UPS a nostra societate emissum. Productum adhibet controllem numericam, designum modularem, et technologiam N+X parallela redundans, quae integra maxima recentia technica in campis electronicarum potentiarum et automatici controlis. Hoc est productum exemplaris in campo modulare UPS.
Capacitas producti comprehendit varios rangos potestatis inter 50kW et 600kW, faciens commodum uti useri possint configure flexibiliter et investire gradatim. Potest operari quattuor machinas paralelas usque ad 2400kW.

Characteres producti

Specificationes technicales
Omnis pars architecturae digitaliter controlatur, cum excellenti performance et alta stabilitate systematis. Habet capacitates self-protectionis et diagnosi fault, simul evitando periculum deficiendi dispositivorum analogicorum, faciens controllem systematis magis stabilis et fidelis.
Adoptans technologia triplex, efficacia totalis machinae attingit 96%.
Designum altae densitatis potentiae, 50KW modulun singulare dimensione (L × P × A) 440 × 620 × 130mm.
Exitus potest coniungi ad onus totaliter inaequabile. Quando exitus coniungitur ad onus inaequabile, currentes input sunt aequatae in tribus phasibus, quod potest aequare onus rete trium phasium.
alta fidelitas
Designum N+X parallel redundancy assecurat disponibilitatem systematis 99.999% et MTBF ultra 250000 horas, complens alta exigentia fidelitatis onerum criticorum in systema suppletionis potentiae; Flexibilis setting parallel redundancy permittit systema praebere maximam capacitatem exitus.
Systema controlis parallel redundancy, cum methodis controlis decentralizata et administrationis centralizata; Unitas controlis centralizata connectitur redundantia paralleliter, et defectus unius non afficit operationem totalem machinae; Optimizatus distributus combiner cabinet assecurat securitatem connectionis systematis paralleliter.
Modulus monitorandi centralizati habet functionem hot swappable. Quando modulus monitorandi extrahitur, systema potest operari normaliter utendo supply bypass centralizata, quod meliorat capacitate supply bypass.
Function EPO, preme bottonem EPO in casibus emergentibus ut urgenter sistas; Botton EPO designatur pro protectione et habet functionem remote emergency shutdown (REPO) ad prohibendum operationem accidentalem.
Commodum et flexibile
Designum modulare, constans ex uno ad duodecim modulis connectis paralleliter, cum maxima potestate 600kW. Useri possunt gradualiter addere numerum modulorum cum flexibilitate; Usur technologia hot swappable, moduli possunt addi et removeri online, assequens tempus "zero" maintenance.
Tempus downtime pro maintenance brevis. Numerus modulorum defectuosorum minor vel aequalis numero modulorum redundantium, et downtime pro maintenance est zero; Numerus modulorum defectuosorum maior numero modulorum redundantium UPS, et downtime pro maintenance non debet superare 5 minutas.
Display LCD tactilis coloris armarii praebet copiosam informationem status UPS, warninges, defectus, etc; Display LED singularis moduli, useri possunt intellegere status operationis moduli per lumina LED moduli.
In casibus emergentibus, UPS potest commutare ad supply bypass maintenance, et personae maintenance possunt secure perficere reparations online.

designum intelligentem
Currentes charging possunt configurari, et useri possunt configurare capacitatem battery et currentes charging per LCD panel ad assequendum automaticam commutationem inter modum constantis voltage charging, modum constantis currentis charging, et modum float charging.
Methodus charging intelligent, adoptans methodum advanced two-stage three-stage charging, potest effective aequare fines rapidi charging et prolongationis vitae battery, salvans investmentem userorum in batteries.
Praebet latum spectrum accessoriorum optionalium, includens transformatores isolationis, distribution panels, SNMP cards, relay dry contact cards, etc., ad formandum systema distributionis parvum ad medium.
Designum viridis
Adoptans armarium standard 19 inch, perfecte congruit environmenti applicationis computer room et salvat area utilis computer room.
Parallel sharing of batteries greatly reduces the number of battery configurations, allowing users to fully configure batteries based on backup time.
Numerus batteries externarum est optional, et useri possunt eligere 30/32/34/36/38/40/42/44/46/48/50 cells (30-50 cells are optional) secundum necessitates suas.

Specificationes technicales

Model HBM90-30 HBM150-30 HBM300-30
Capacity      
UPS Cabinet 30-90kVA 30-150KVA 30-300KVA
Power Module 30kVA 30kVA 30kVA
Input      
Input Mode Three-phase Four-wire + Ground
Rated Voltage 380/400V/415Vac
Voltage Range 208~478Vac
Frequency Range 40~70Hz
Power Factor ≥0.99
Bypass Range 380 upper limit: 25% (optional +10%, +15%, +20%)
 
400 upper limit: 20% (optional +10%, +15%)
 
415 upper limit: 15% (optional +10%)
 
Lower limit: -45% (optional -20%, -30%)
 
Bypass frequency protection range: ±10%
Input Current Harmonic ≤3% (100% Non-linear Load)
Output  
Output Mode Three-phase Four-wire + Ground
Rated Voltage 380/400V/415Vac
Power Factor 0.9 or 1
Voltage Accuracy ±1%
Output Frequency  
Mains Mode Synchronous with input; when mains frequency exceeds maximum ±10% (can be set to ±1%, ±2%, ±4%, ±5%), output frequency is 50×(±0.2%)Hz
Battery Mode (50/60±0.2%)Hz
Load Crest Factor 3:1
Switching Time Mains mode to bypass mode: 0ms (tracking); Mains mode to battery mode: 0ms
Overload Capacity Load ≤110%, 60min; ≤125%, maintain 10min; ≤150% maintain 1min; ≥150% switch to bypass immediately
Output Voltage Harmonic ≤2% (100% Linear Load)
Efficiency 95% in Normal Mode
Communication Interface RS232, RS485, 2 Intelligent Slot (Smart Card Slot), Dry Contact
Battery  
Battery Voltage ±192V±204V±216V±228V±240V DC; (32, 34, 36, 38, 40 cells optional)
Charging Current  
UPS Cabinet 30A Max. 50A Max. 100A Max.
Power Module 10A Max. 10A Max. 10A Max.
Working Environment      
Working Temperature 0℃ ~ 40℃ 0℃ ~ 40℃ 0℃ ~ 40℃
Relative Humidity 0 ~ 95% non condensing
Storage Temperature -25℃ ~ 55℃
Altitude < 1500m < 1500m < 1500m
Physical Characteristics  
Appearance Dimensions (D×W×H) mm      
Cabinet 840 x 600 x 1400 840 x 600 x 1400 1100 x 600 x 2000
Module 580 x 443 x131 580 x 443 x131 580 x 443 x131
Weight (Net Weight) Kg      
Cabinet 158 170 305
Module 30K module, 33.5KGS
Execution Standard CE,EN/IEC 62040-2, EN/IEC 62040-1-1, YD/T1095-2008

 

Model HBM300-50 HBM400-50 HBM500-50 HBM600-50
Capacity        
Cabinet 50-300KW 50-400KW 50-500KW 50-600KW
Module 50KW 50KW 50KW 50KW
Maximum Number of Modules 6 8 10 12
Input  
Main Path Input  
Rated Input Voltage (Vac) 380/400/415
Input Voltage Range (Vac) 138 ~ 485Vac
Wiring Mode Three-phase Five-wire
Input Frequency Range (Hz) 40-70
Input Power Factor ≥0.99
Input Current Harmonic (THDi) ≤3% (100% Linear Load)
Bypass Input  
Rated Input Voltage (Vac) 380/400/415
Input Voltage Range (Vac) 220 upper limit: 25% (optional +10%, +15%, +20%) 230 upper limit: 20% (optional +10%, +15%) 240 upper limit: 15% (optional +10%) lower limit: -45% (optional -10%, -20%, -30%)
Wiring Mode Three-phase Five-wire
Bypass Synchronous Tracking Range (Hz) ±10%
Generator Input Supported
Power Walking In Supported
Bypass Reverse Feeding Supported
Output  
Voltage (Vac) 380/400/415±1%
Power Factor 1
Frequency (Hz)  
Mains Mode ±1%/±2%/±4%/±5%/±10% (Configurable)
Battery Mode (50/60±0.1%)Hz
Waveform Sine Wave
Current Crest Ratio 3:1
Output Voltage Harmonic (THDV) ≤2% (100% Linear Load); ≤3% (100% Non-linear Load)
Switching Time (ms) 0
Overall Efficiency (%) 96
Overload Capacity 110% load, transfer to bypass after 60min; 125% load, transfer to bypass after 10min; 150% load, transfer to bypass after 1min
Battery  
Maximum Module Charging Current (A) 20
Battery Voltage 30~50 cells optional, default 36 cells; optional voltages: ±180V/±192V/±204V/±216V/±228V/±240V/±252/±264/±276/±288/±300Vdc (30/32/34/36/38/40/42/44/46/48/50 cells)
Environment  
Working Temperature 0℃ ~ 40℃
Storage Temperature —25℃ ~ 55℃
Humidity Range 0 ~ 95% (Non-condensing)
Working Altitude < 1500m (Derate for use above 1500m)
Noise (1m Distance) <68dB <70dB <70dB <70dB
Other Functions        
Protection Functions Short circuit, overload, over temperature, output over voltage, battery under voltage, fan fault alarm, bypass reverse feeding, lightning protection
Alarm Functions Mains abnormality, overload, UPS fault, battery under voltage and other multiple alarm functions
Communication Functions CAN, RS485, Network Interface, Dry Contact, Parallel Interface, LBS Interface, Smart Card Slot, Temperature Sensor Interface
Mechanical Characteristics  
Dimensions (W×D×H)  
Cabinet (mm) 600×850×2000 600×850×2000 (Standard); 1200×850×2000 (Fully Loaded) 1200×850×2000 1200×850×2000
Module (mm) 440×620×130
Net Weight  
Cabinet (kg) 260 280/600 645 720
Module (kg) 32
Execution Standard YD/T 2165-2010
FAQ pro
Q: Quae sunt commoditates series HBM UPS modulare comparata cum UPS turris traditionale
A:

Comparata cum UPS tradicionalibus turriculis, haec habet praegrandia: ① Expansio flexibilis: Capacitas adiici potest per modulos secundum necessitatem, initium superinvestmentis vitatur; ② Fidelitas magna: Design N+X redundancy eliminat singularem punctum deficiendi, et moduli qui calefacti mutari possunt reducunt MTTR (medium tempus reparationis) ad minuta; ③ Energiarum parsimonia: Efficiens AC-AC usque ad 97%, efficiens ECO modus usque ad 99%; ④ Spatii parsimonia: Design densitas potentiae alta (exempli gratia, 60kW modulo in spatio 3U) spatium installationis servat; ⑤ Facilis cura: Design moduli independentis simpliciter diagnostica culpae et substitutionem.

Q: Quid est functio principalis et principium operativum series HBM UPS modularis
A:

 Functio eius fundamentalis est praebere alimentationem electricam ininterruptam altae fiduciae pro oneribus criticis, cum advantage flexibilis expansionis capacitatis et parva manutentio. Principium operativum fundatur super technologia parallela N+X redundans: singulae moduli potestativi operantur independenter et dividunt onus aequabiliter; quando rete publicum normaliter operatur, stabilivit tensionem, filtrat harmonicos et praebet alimentationem oneribus simulque carica baterias; quando rete publicum deficit, transmutat ad alimentationem per baterias cum tempore conversionis 0ms. Moduli defectivi possunt substitui in calido sine cessatione systematis, assecurantes disponibilitatem systematis 99.999%.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum