mababang pagsusunod na online UPs power supply (3phase input 1phase output)

  • low frequency on-line UPs power supply (3phase input 1phase output)

Mga Pangunahing Katangian

Brand Switchgear parts
Numero ng Modelo mababang pagsusunod na online UPs power supply (3phase input 1phase output)
Larawan na Pagsasahimpapawid 50/60Hz
Lalabas na voltaje 405VDC/220VDC
Tensyon ng Input 380V
Kapasidad 15kVA
Serye HBD

Mga Deskripsyon ng Produkto mula sa Supplier

Pagsasalarawan

Mga Katangian ng Produkto

Pamamahala sa teknolohiyang digital na may kakayahang mag-isip
Gamit ang mabilis na microcontroller ng Intel at mga device ng programmable logic upang makamit ang kontrol ng circuit, pagtakda ng parametro, pamamahala ng operasyon, advanced na self-test at self-detection functions, ito ay maaaring gumawa ng self-test at fault analysis sa lahat ng independiyenteng koneksyon ng circuit sa circuit board. Maaari kang maging buong tiwala sa sine wave voltage na naidigital at bagong solusyon para sa perpektong operasyon upang mapasado ang iyong aktwal na pangangailangan.
Epektibong teknolohiya ng IGBT (Insulated Gate Bipolar Transistor) inverter
Ang IGBT ay may kahanga-hangang high-speed switching characteristics; Mayroong mga katangian ng mataas na voltag at malaking current; Gamit ang voltage type drive, kailangan lamang ng maliit na control power. Ang ika-anim na henerasyon ng IGBT ay may mas mababang saturation voltage drop, mas mataas na inverter efficiency, at mas mataas na reliabilidad.
Pinakamahusay na load characteristics
Nakakapagbibigay ng buong pagsasalin mula sa 0 hanggang 100% load nang hindi nagbabago sa bypass, at protektahan ang stable at maaswang output.
Humanized na malaking LCD display sa Chinese at English
Ang malaking screen ay nagpapakita ng menu sa Chinese at English, na may malinaw na flow chart na nagpapakita ng operational status, na nagbibigay-daan sa flexible na pag-implementa ng mga function ng human-machine dialogue. Intuitive na LED status indication, workflow style na status indication, malinaw sa isang tingin.
Mataas na performance dynamic characteristics
Ang multiple feedback controls tulad ng instantaneous control at effective value ay ginagamit upang makamit ang mataas na dynamic regulation at bawasan ang distortion ng output voltage.
Kompletong function ng proteksyon
Ang multiple system protection at alarm functions, kasama ang input/output overvoltage protection, input surge protection, phase sequence protection, battery low voltage protection, output overvoltage protection, at high temperature protection.
Intelligent na pamamahala ng battery
Intelligent na charging ng battery: Automatic adjustment ng charging parameters ng battery batay sa configuration ng battery ng user, at paggawa ng equalization at float charging conversion, temperature compensation charging at discharging management sa battery batay sa environment ng power supply. Paghahaba ng lifespan ng battery at pagbawas ng burden sa mga administrator.
Paggamit ng 6-pulse (optional 12 pulse) rectifier charger habang idinadagdag ang input harmonic filter
Epektibong supresyon ng input harmonic pollution, pagpapabuti ng input power factor ng UPS power supply, at pagbawas ng input harmonic current.
intelligent monitoring
Ang RS232 at RS485 communication ports ay tunay na nagbibigay ng multi-purpose communication at remote monitoring. Optional na SNMP card para sa remote monitoring at network management; Optional na dry contact interface, gamit ang passive contacts upang monitorin ang status ng UPS.

Larangan ng Application
Sapat para sa mga industriya tulad ng finance, telecommunications, securities, taxation, transportation, insurance, government, building lighting, road traffic lighting, electricity, at industrial at mining enterprises.

Tehnikal na Specifications

Model HBD-6KS HBD-10KS HBD-15KS HBD-20KS HBD-30KS HBD-40KS HBD-50KS HBD-60KS HBD-80KS
Nominal Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 40KVA 50KVA 60KVA 80KVA
Working Mode and Principle Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology Online Power Supply, Static Bypass Switch (No-break Switching), Double Conversion Technology
AC Input                  
Phase Number Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G) Three Phase (A, B, C+N+G)
Input Nominal Voltage 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC 380 VAC
Input Voltage Range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25%
Nominal Frequency 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10% 50Hz ± 10%, 60Hz ± 10%
Voltage Harmonic Distortion <5% <5% <5% <5% <5% <5% <5% <5% <5%
Soft Start 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec 0~100% 5sec
Battery (Maintenance-free Lead-acid Battery)                  
Nominal Voltage 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC 360VDC/192VDC
Quantity Unit 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series) 30 cells/12V in series (16 cells/12V in series)
Charging                  
Maximum Output Voltage 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC 405VDC/220VDC
Float Voltage 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC) 405VDC/220VDC (Automatic Battery Equalization Once Every 3 Months, Charging Voltage 435VDC/232VDC)
Microcomputer-set Charging Current 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity) 1A~50A (Automatically Adjusted to 0.1C According to Battery Capacity)
AC Output                  
Rated Power (KW COSφ=0.8) Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8 Nominal Power × 0.8
Phase Number Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G) Single Phase (L+N+G)
Nominal Phase Voltage 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation) 220VAC ± 1% (Stable Load), 220VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply) 50Hz ± 0.1% (Battery Power Supply)
Frequency Stability: Asynchronous < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1% < ± 0.1%
Frequency Stability: Synchronous < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5% < ± 5%
Crest Factor 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1 3: 1
Output Waveform Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave Sine Wave
Total Harmonic Distortion Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5% Linear Load < 3%; Non-linear Load < 5%
Operating Temperature 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃ 0~40℃
Relative Humidity 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation) 30%~90% (No Condensation)
Operating Altitude < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 3000 Meters)
Options RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements RS485 Network Adapter (SNMP) / Cabinet Size Can Be Designed According to Requirements
Dimensions (W×D×H) mm 390×659×860 430×760×1350 710×720×1450 710×850×1500 - - - 1100×860×1680 -
Main Unit Weight 150 199 220 305 380 480 566 590 986

Pansin: Ang modelo na may nakabultong baterya at espesyal na mga pangangailangan sa voltihe ay maaaring pasadyahan batay sa aktwal na kalagayan ng user, at isusunod ang hiwalay na presyo.

Mga Karaniwang Tanong para sa
Q: Paano makakalunas ng mga karaniwang suliraning ito ng UPS?
A:

① Overload alarm: Unplug non-essential single-phase loads, or replace with a larger capacity UPS; ② Phase loss alarm: Check 3-phase input wiring, repair loose or disconnected cables; ③ Battery low alarm: Charge continuously for 12 hours, replace aging batteries if the alarm persists; ④ Output voltage abnormal: Check output wiring, reset UPS (disconnect power and restart after 5 minutes); ⑤ Transformer overheating: Stop using immediately, check ventilation and load, contact after-sales for maintenance.

① Alarm ng sobrang bigat: Itakda ang mga hindi mahalagang singko-pase na pag-load, o palitan ito ng mas malaking kapasidad na IEE-Business; ② Alarm ng nawawalang pase: Suriin ang pag-wire ng 3-pase input, ayusin ang mga maluwag o nai-disconnect na kable; ③ Alarm ng mababang baterya: Puksain nang walang tigil sa loob ng 12 oras, palitan ang mga lumang baterya kung patuloy ang alarm; ④ Abnormal na output voltage: Suriin ang pag-wire ng output, i-reset ang IEE-Business (i-disconnect ang power at i-restart pagkatapos ng 5 minuto); ⑤ Sobrang mainit ng transformer: I-stop ang paggamit agad, suriin ang ventilation at load, makipag-ugnayan sa after-sales para sa maintenance.

Q: Ano ang pangunahing punsiyon at prinsipyo ng paggana ng 3-phase input 1-phase output na may mababang frequency na on-line UPS?
A:

Ang pangunahing punsiyon nito ay maging paglipat ng 3-phase mains power sa matatag na 1-phase power, nagbibigay ng walang paghihiwalay at malinis na kuryente para sa single-phase critical loads habang inaasikaso ang mga problema sa mains tulad ng pagbabago ng voltage, harmonic interference, at power outage. Prinsipyo ng paggawa: Pagsasama ng double conversion (AC-DC-AC) + disenyo ng low-frequency transformer. Kapag normal ang mains, ang 3-phase AC ay inililipat sa DC upang kargahan ang battery, pagkatapos ay inililipat ang DC sa 1-phase pure sine wave AC para sa suplay ng load; kapag nabigo ang mains, ito ay lumilipat sa battery power na may 0ms transfer time,

Alamin ang iyong supplier
Tindahan Online
Rate ng on-time delivery
Oras ng Pagsagot
100.0%
≤4h
Pangkalahatang Impormasyon ng Kompanya
Lugar ng Trabaho: 1000m² Kabuuang bilang ng mga empleyado: Pinakamataas na Taunang Export (US Dollar): 300000000
Lugar ng Trabaho: 1000m²
Kabuuang bilang ng mga empleyado:
Pinakamataas na Taunang Export (US Dollar): 300000000
Serbisyo
Uri ng Pagnenegosyo: Sales
Pangunahing Kategorya: Mga Aksesorya ng Pagsasakatawan/Pagsusuri ng mga aparato/Mataas na Voltaheng mga Aparato/Mga aparato sa mababang voltaje/Instrumentasyon/Mga Pagsasagawa ng Produksyon/Pangkalahatang Paggamit ng Enerhiya sa Pagproseso ng IEE-Business
Pamamahala ng Buhay
Mga serbisyo sa pangangalaga at pamamahala sa buong buhay para sa pagbili, paggamit, pagpapanatili, at售后 ng kagamitan, upang masiguro ang ligtas na operasyon ng mga kagamitang pangkuryente, tuluy-tuloy na kontrol, at maaliwalas na pagkonsumo ng kuryente.
Ang supplier ng kagamitan ay nakapasa sa sertipikasyon ng karapatang pumasok sa platform at teknikal na pagtatasa, tinitiyak ang pagtugon, propesyonalismo, at katiyakan mula pa sa pinagmulan.

Mga Produkto na May Kaugnayan

Kaalamayan na may Kaugnayan

  • Mga Aksidente sa Pangunahing Transformer at mga Isyu sa Pagsasanay ng Light Gas
    1. Tala ng Aksidente (Marso 19, 2019)Noong ika-16:13 ng Marso 19, 2019, inulat ng monitoring background ang isang light gas action ng No. 3 main transformer. Ayon sa Code for Operation of Power Transformers (DL/T572-2010), sinaunang tiningnan ng mga tauhan ng operation and maintenance (O&M) ang kondisyon ng No. 3 main transformer sa lugar.Konfirmasyon sa lugar: Inulat ng WBH non-electrical protection panel ng No. 3 main transformer ang isang Phase B light gas action ng katawan ng transformer
    02/05/2026
  • Mga Kamalian at Pamamaraan sa Paggamot ng Single-phase Grounding sa 10kV Distribution Lines
    Mga Katangian at mga Device na Paggamit sa Pagkakakilanlan ng Single-Phase Ground Fault1. Mga Katangian ng Single-Phase Ground FaultMga Signal ng Sentral na Alarm:Tumutunog ang bell ng babala, at nag-iilaw ang indicator lamp na may label na “Ground Fault sa [X] kV Bus Section [Y].” Sa mga sistema na may Petersen coil (arc suppression coil) na nakakonekta sa neutral point, nag-iilaw din ang indicator na “Petersen Coil Operated.”Mga Indikasyon ng Insulation Monitoring Voltmeter:Bumababa ang voltag
    01/30/2026
  • Pamamaraan ng pag-ground ng neutral point para sa 110kV~220kV power grid transformers
    Ang pagkakasunod-sunod ng mga paraan ng pag-ground ng neutral point sa mga transformer ng power grid na 110kV~220kV ay dapat tugunan ang mga pangangailangan ng insulation withstand ng mga neutral points ng mga transformer, at kailangang ito ring panatilihin ang zero-sequence impedance ng mga substation na hindi masyadong nagbabago, habang sinisigurado na ang zero-sequence comprehensive impedance sa anumang short-circuit point sa sistema ay hindi liliit ng tatlong beses ang positive-sequence comp
    01/29/2026
  • Bakit Gumagamit ng Bato Gravel Pebbles at Crushed Rock ang mga Substation?
    Bakit Gumagamit ng Bato, Gravel, Pebbles, at Crushed Rock ang mga Substation?Sa mga substation, ang mga kagamitan tulad ng power at distribution transformers, transmission lines, voltage transformers, current transformers, at disconnect switches ay nangangailangan ng pag-ground. Sa labas ng pag-ground, susuriin natin nang mas malalim kung bakit karaniwang ginagamit ang gravel at crushed stone sa mga substation. Bagama't tila ordinaryo lang sila, ang mga bato na ito ay gumaganap ng mahalagang pap
    01/29/2026
  • Bakit Kailangan I-ground ang Core ng Transformer sa Iisang Punto Lamang? Hindi ba Mas Handa ang Multi-Point Grounding?
    Bakit Kailangan I-ground ang Core ng Transformer?Sa panahon ng operasyon, ang core ng transformer, kasama ang mga metal na istraktura, bahagi, at komponente na naka-fix sa core at windings, ay lahat nasa malakas na elektrikong field. Sa impluwensya ng elektrikong field na ito, nakakakuha sila ng relatyibong mataas na potensyal sa paghahambing sa lupa. Kung hindi grounded ang core, magkakaroon ng potential difference sa pagitan ng core at ng mga grounded clamping istraktura at tank, na maaaring m
    01/29/2026
  • Pag-unawa sa Neutral Grounding ng Transformer
    I. Ano ang Neutral Point?Sa mga transformer at generator, ang neutral point ay isang tiyak na punto sa winding kung saan ang absolutong voltaje sa pagitan ng punto na ito at bawat panlabas na terminal ay pantay. Sa diagrama sa ibaba, ang puntoOay kumakatawan sa neutral point.II. Bakit Kailangan ng Pag-ground ang Neutral Point?Ang elektrikal na paraan ng koneksyon sa pagitan ng neutral point at lupa sa isang tatlong-phase AC power system ay tinatawag naneutral grounding method. Ang paraan ng pag-
    01/29/2026
Hindi pa rin nakakahanap ng tamang supplier Let verified suppliers find you Kumuha ng Kita Ngayon
Hindi pa rin nakakahanap ng tamang supplier Let verified suppliers find you
Kumuha ng Kita Ngayon
Inquiry
+86
I-click para i-upload ang file
I-download
Kumuha ng IEE-Business Application
Gamit ang app na IEE-Business upang makahanap ng kagamitan makuha ang mga solusyon makipag-ugnayan sa mga eksperto at sumama sa industriyal na pakikipagtulungan kahit kailan at saanman buong pagsuporta sa pag-unlad ng iyong mga proyekto at negosyo sa enerhiya