Niskofrekvencijska on-line UPS napajanja (3fazni ulaz i 3fazni izlaz)

  • Low frequency on-line UPs power supply (3phase in and 3phase out)

Ključne karakteristike

Бренд Switchgear parts
Број модела Niskofrekvencijska on-line UPS napajanja (3fazni ulaz i 3fazni izlaz)
Nominalna frekvencija 50/60Hz
Ulazna naponska razina 380VAC
Kapacitet 20kVA
Серија HBS

Opisi proizvoda od strane dobavljača

Opis

Serija HBS visokosnagovih tri u tri izlaza inteligentnih neprekidnih napajalnih uređaja ima pojedinačnu snagu od 6KVA do 400KVA. Ovaj proizvod je visoko inteligentan napajajući proizvod koji integriše digitalizaciju, informatizaciju i mrežnu tehnologiju. Koristi visokobrzinski mikroprocesor (MCU) i ASIC DDC kontrolnu tehnologiju, i poseduje snažne mogućnosti
veliki sistem za prikupljanje informacija, sistem za obradu signala, monitorinški sistem i kompleksni zaštitni sistem; široko se koristi u različitim električnim okruženjima, kao što su visoki zgrade, javno osvetljenje, energetski sektor, industrijski i rudarski preduzeća, mrežne računalne sobe i druge industrije. Personalizovan dizajn, prijatna funkcija ljudsko-računarske interakcije, intuitivni bojni displej na kineskom i engleskom jeziku
bojni displej i statusni indikator nadzorne površine omogućavaju korisnicima lakše upravljanje i korišćenje.

Značajke proizvoda

Inteligentna digitalna kontrolna tehnologija:
Korišćenjem visokobrzinskih mikrokontrolera i programiranih logičkih uređaja postiže se kontrola kruga, podešavanje parametara, operativno upravljanje, napredne funkcije samoprovjere i samodiagnostike, može se izvršiti samoprovjera i analiza grešaka svih nezavisnih vezivanja na ploči. Možete potpuno vjerovati transformisanom sinusoidnom naponu i novom rešenju za savršeno funkcionisanje kako biste ispunili vaše stvarne potrebe. )
Efikasna IGBT (Izolovani dvopolni tranzistor) inverter tehnologija:
Dobra karakteristika brzog prekidača IGBT-a; posjeduje radne karakteristike visokog naponskog i strujnog kapaciteta; korišćenjem voltanog pogona, potrebna je samo mala kontrolna snaga. Peto generacije IGBT-a ima niži nivo nasitnog pada napona, veću efikasnost invertera i veću pouzdanost.
Fleksibilna paralelna tehnologija:
Prijatna za jedinstvene mašine, 1+1 paralelne, i N+1 paralelne redundancijske sisteme sa različitim opterećenjima.
Nepremeštena opterećenja karakteristika:
Usvojena tri faze potpuno nezavisne PWM modulacija i pun most IGBT inverter tehnologija, potpuno zadovoljava prelaz od 0 do 100% opterećenja bez prebacivanja na bypass, i štiti stabilan i pouzdan izlaz.
Humaniziran 7-inčni veliki LCD ekran sa kineskim i engleskim bojnim dodirnim ekranom:
7-inčni veliki LCD ekran prikazuje kineske i engleske menije, sa jasnim dijagramom toka koji pokazuje stanje rada i fleksibilnom funkcijom ljudsko-računarske komunikacije. Dodirni ekran ima funkciju zabeležavanja događaja i operacije menija dostupne su na kineskom i engleskom jeziku.
Kompletna funkcija zaštite:
Više sistema zaštite i alarmnih funkcija, uključujući zaštitu od pretjeranog ulaznog i izlaznog napona, zaštitu od ulaznog talasa, zaštitu od faze, zaštitu od pretjerane nabavke i ispraznjenosti baterije, zaštitu od preopterećenja i kratkog spoja izlaza, i zaštitu od visoke temperature.
Visok performans dinamičkih karakteristika:
Prihvaćene su više povratnih kontrola, kao što su trenutna kontrola i efektivna vrednost, kako bi se postigla visoka dinamička regulacija i smanjio naponski deformativitet.
6 impulsa (opcioni 12 impulsi)
Rectifikator-naplatni uređaj takođe dodaje filter harmoničkih valova na ulazu kako bi se efikasno suzbijala harmonijska zagađenja ulaza, poboljšana je faktor snage ulaza UPS napajanja, i smanjena je harmonijska struja na ulazu.
Inteligentno upravljanje baterijama:
Inteligentno punjenje baterija, automatski prilagođava parametre punjenja baterije prema konfiguraciji baterije korisnika, i vrši konverziju između ravnotežnog i plavog punjenja, temperaturnu kompenzaciju punjenja, upravljanje ispraznjenjem na osnovu okruženja napajanja kako bi se produžila životna doba baterije i smanjeno opterećenje administratora.
Kompletna izolaciona tehnologija
Ulaz i izlaz su potpuno izolovani kako bi se smanjile harmonijske struje i direktna interferencija mrežnog napajanja.
Inteligentno komunikacijsko upravljanje:
RS232 i RS485 komunikacioni portovi stvarno ostvaruju višestruku komunikaciju i daljinsko nadgledanje. Opcioni SNMP kartica omogućava daljinsko nadgledanje i mrežno upravljanje, a opcioni suhi kontakt interfejs koristi pasivne kontakte za nadgledanje stanja UPS-uređaja.

Tehničke specifikacije

Model HBS-6KS HBS-10KS HBS-15KS HBS-20KS HBS-30KS HBS-40KS HBS-50KS HBS-60KS HBS-80KS HBS-100KS HBS-120KS HBS-150KS HBS-200KS HBS-250KS HBS-300KS HBS-400KS
Nominal Capacity (kVA) 6 10 15 20 30 40 50 60 80 100 120 150 200 250 300 400
Overall Working Mode and Principle Online Power Supply, Static Bypass Switch (Uninterrupted Switching), Double Conversion Technology, Output Power Fully Isolated
Rectifier Working Mode 6-pulse (12-pulse Optional) Rectification

Input  
Phase Number

Three Phase + N + G

Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Voltage Harmonic Distortion < 5%
Soft Start 0-100% 5S
Nominal Output DC Voltage 405VDC
Rated Power (KW, Cosφ=0.8) Nominal Power × 0.8
Inverter  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 1% (Stable Load), 380VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.5%, 60Hz ± 0.5% (Battery Power Supply)
Frequency Stability < ± 0.5% (Asynchronous)
Frequency Tracking Range 50Hz ± 5%
Crest Factor 3:1
Output Waveform Sine Wave
Output Waveform Distortion Linear Load < 3%; Non-linear Load < 5%
Dynamic Load Voltage Transient < ± 5% (0 to 100% Load Change)
Instantaneous Recovery Time < 10ms
Overload Capacity 125% 1min, 150% 1s
Inverter Efficiency ≥95% (100% Load)
Bypass  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Conversion Time 0ms (Inverter/Bypass)
Battery Charging  
Battery Type Maintenance-free Lead-acid Battery
Maximum Output Voltage 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC
Microcomputer-set Charging Current 1A~100A (Set According to Battery Capacity, Automatically Adjusted to 0.1C)
Quantity Unit 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series)
Charging Current 1A~100A (Automatically Adjusted to 0.1C According to Battery Capacity)
Nominal Battery Voltage 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC
Float Voltage 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC)
Efficiency > 80% (100% Load)
System  
Computer Communication Interface Standard RS232, Optional RS485, Dry Contact, SNMP Remote Monitoring Network Adapter
Operating Temperature 0-40℃
Relative Humidity (No Condensation) 30% - 90%
Operating Altitude (Maximum) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 4000 Meters)
Cooling Method Temperature-controlled Forced Air Cooling
Noise dB (1m from the Machine, Depending on Load and Temperature) 40-50 40-50 45-55 45-55 50-55 50-55 55-65 55-65 55-65 55-65 55-65 65-70 65-70 65-70 65-70 65-70
Cabinet Color Black (Optional)
Input Cable Bottom/Back
Easy Maintenance Top/Left/Right Sides Can Be Opened
External Dimensions W×D×H(mm) 390×660×860 450×725×1035 710×720×1450 710×850×1500 1100×860×1680 1100×860×1680 1500×1160×1800 1500×1160×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800
Weight (kg) 150 212 260 352 396 485 568 635 903 951 1052 1355 1586 1850 2170 3155
Input and Output Devices Terminal Block
ЧПП за
Q: Koje prednosti ima u poređenju sa visokofrekvencijskim 3-faznim onlajn UPS-om?
A:

U poređenju sa UPS-om visoke frekvencije, ima očigledne prednosti: ① Veća pouzdanost: transformator niske frekvencije ima snažnu mogućnost preopterećenja (podržava 125% preopterećenje tokom 10 minuta) i otpornost na interferenciju; ② Bolja stabilnost: prikladan za teške industrijske okruženja sa velikim fluktuacijama napona i visokim harmonikama; ③ Duži vremenski rok korišćenja: komponente niske frekvencije imaju manje zagrevanje i iznose, vreme korišćenja do 10-15 godina; ④ Snažnija prilagodljivost opterećenju: kompatibilan sa induktivnim, kapacitivnim i rezistivnim opterećenjima (poput motora, inverzora).

Q: Koja je osnovna funkcija i princip rada 3-faznog ulaza i 3-faznog izlaza niskofrekventnog on-line UPS-a?
A:

Jezgra funkcija je da pruži neuglušan, stabilan i čist struju za industrijske opterećenja velike snage, sa funkcijama stabilizacije napona, harmonijskog filtriranja i zaštite od preopterećenja. Radni princip je dvostruka konverzija (AC-DC-AC): kada je mrežna struja normalna, pretvara 3-faznu AC u DC kako bi se nabijala baterija, zatim pretvara DC u stabilnu 3-faznu čistu sinusoidnu AC za opskrbu opterećenja; kada mrežna struja pada, prebacuje se na opskrbu iz baterije sa vremenom prebacivanja od 0ms, obezbeđujući da nema prekida u radu opterećenja.

Upoznajte svog dobavljača
Online prodavnica
Stopa na vreme dostave
Vreme odgovora
100.0%
≤4h
Pregled kompanije
Radno mesto: 1000m² Ukupan broj zaposlenih: Najveći godišnji izvoz (USD): 300000000
Radno mesto: 1000m²
Ukupan broj zaposlenih:
Najveći godišnji izvoz (USD): 300000000
Услуге
Vrsta poslovanja: Продаја
Glavne kategorije: Dodaci za uređaje/Oprezna oprema/Visoki napon aparati/Niskonaponski uređaji/мерање инструменти/Proizvodno opreme/Električni pribor
Menadžer doživotne garancije
Услуге менаџмента бриге у току целог животног циклуса за набавку, коришћење, одржавање и сервис по продаји, како би се осигурала безбедна експлоатација електричне опреме, стална контрола и непрекидно коришћење електричне енергије
Добављач опреме је положио сертификацију квалификација платформе и техничку процену, чиме се осигурава усклађеност, стручност и поузданост од извора

Povezani proizvodi

Povezana znanja

  • Glavne transformatorne nesreće i problemi sa radom na svetlostima plinova
    1. Zapisnik o nesreći (19. mart 2019)Dana 19. marta 2019. u 16:13 sati, nadzorna ploča je izveštavala o delovanju lege plinove na glavnom transformatoru broj 3. U skladu sa Pravilnikom o eksploataciji transformatora napona (DL/T572-2010), osoblje za održavanje i rad (O&M) proverilo je stanje na mestu glavnog transformatora broj 3.Potvrđeno na mestu: Panele WBH neelektrične zaštite glavnog transformatora broj 3 su izveštavale o delovanju lege plinove faze B tela transformatora, a resetovanje
    02/05/2026
  • Kvarovi i obrada jednofaznog zemljenja na distribucijskim linijama od 10kV
    Карактеристике и уређаји за откривање једнофазних земљних кратких спојева1. Карактеристике једнофазних земљних кратких спојеваЦентрални алармски сигнали:Звонце за упозорење звучи, а индикаторска лампица означена „Земљни кратки спој на [X] кВ шинском одељку [Y]“ се укључује. У системима са земљним везивањем нулте тачке преко Петерсенове калемске спирале (калем за гашење лука), такође се укључује индикатор „Петерсенова калемска спирала у раду“.Показивања волтметра за надзор изолације:Напон погођен
    01/30/2026
  • Neutralni način operacije zemljanja za transformere mreže od 110kV~220kV
    Način povezivanja neutralne tačke na transformatorima mreže od 110kV do 220kV treba da zadovolji zahteve izolacije neutralnih tačaka transformatora, i treba da se nastoji da se nula-sequens impedansa podstaničnih stanica održi gotovo nepromenjena, dok se osigurava da nula-sequens kompletan impedans u bilo kojoj tački prekidnice sistema ne premaši tri puta pozitivno-sequens kompletan impedans.Neutralni načini zemljanja novih i tehnički unapređenih transformatora od 220kV i 110kV treba strogo da s
    01/29/2026
  • Zašto podstanci koriste kamenje šljunku mrvlje i drobljen kamen?
    Zašto se u podstanicama koriste kamenje, šljunka, kamenčići i drobljeni kamen?U podstanicama, oprema poput transformatora snage i distribucije, prenosnih linija, transformatora napona, transformatora struje i prekidača za odvajanje svi zahtevaju zemljanje. Osim zemljanja, sad će se detaljno istražiti zašto su šljunke i drobljeni kamen često korišćeni u podstanicama. Iako izgledaju obično, ovi kamenji igraju ključnu ulogu u pitanju bezbednosti i funkcionalnosti.U dizajnu zemljanja podstanica - po
    01/29/2026
  • Zašto se jezgra transformatora mora zemljiti samo na jednoj tački Nije višetačka zemlja pouzdanija
    Zašto se jezgra transformatora mora zemljiti?Tokom rada, jezgra transformatora, zajedno sa metalnim konstrukcijama, delovima i komponentama koje fiksiraju jezgru i navojnice, nalazi se u jakom električnom polju. Pod uticajem ovog električnog polja, oni stječu relativno visok potencijal u odnosu na zemlju. Ako se jezgra ne zemlji, postoji će razlika potencijala između jezgre i zemljenih klampnih konstrukcija i rezervoara, što može dovesti do prekidnog iscrpljivanja.Dodatno, tokom rada, jako magne
    01/29/2026
  • Razumevanje neutralne zaklopnje transformatora
    I. Šta je neutralna tačka?U transformatorima i generatorima, neutralna tačka je specifična tačka u vijku gde je apsolutno napona između ove tačke i svakog spoljnog terminala jednako. U sledećem dijagramu, tačkaOpredstavlja neutralnu tačku.II. Zašto treba zemljiti neutralnu tačku?Električni način povezivanja neutralne tačke i zemlje u trofaznom AC sistemu snabdjevanja električnom energijom naziva semetod zemljitve neutralne tačke. Ova metoda zemljitve direktno utiče na:Sigurnost, pouzdanost i eko
    01/29/2026
Još uvek niste pronašli odgovarajućeg dobavljača? Neka verifikovani dobavljači dođu do vas. Dobijte ponudu sada
Još uvek niste pronašli odgovarajućeg dobavljača? Neka verifikovani dobavljači dođu do vas.
Dobijte ponudu sada
Pošalji upit
+86
Кликните да отпремите фајл
Преузми
Preuzmi IEE Business aplikaciju
Koristite IEE-Business aplikaciju za pronalaženje opreme dobijanje rešenja povezivanje sa stručnjacima i učešće u industrijskoj saradnji bilo kada i bilo gde potpuno podržavajući razvoj vaših projekata i poslovanja u energetskom sektoru