Pastki chastotali onlayn UPS elektr energiyasi (3 fazali kirish va 3 fazali chiqish)

  • Low frequency on-line UPs power supply (3phase in and 3phase out)

Asosiy xususiyatlari

Бренд Switchgear parts
Модель рақами Pastki chastotali onlayn UPS elektr energiyasi (3 fazali kirish va 3 fazali chiqish)
Nominal frekvensiya 50/60Hz
Kirish voltajining qiymati 380VAC
Ko'rsatkich 20kVA
Серия HBS

Taomatchilar tomonidan taqdim etilgan mahsulot tavsiflari

Tavsif

HBS seriyasi zamonaviy uch kirish-uch chiqishli aqlli beko'zlanmagan elektr energiyasi ta'minot tizimi har bir mashina qobiliyati 6KVA dan 400KVA gacha bo'lgan oraliqdagi kapasitetga ega. Bu mahsulot, raqamli, ma'lumotlar bazasiga va tarmoqlashgan tekshiruv usullarini birlashtirgan yuqori intellektual energiya ta'minoti hisoblanadi. Tez ishlov beradigan mikroprotsessor (MCU) va ASIC DDC nazorat texnologiyalaridan foydalanilgan. Uning katta ma'lumotlarni to'plash, signalni ishlash, monitoring va umumiy himoya tizimlari mavjud; bu mahsulot ko'p xil elektr energiyasi muhitida, masalan, yuklangan binolarda, yo'l osvoshida, energetika, madaniy-kimyo korxonalarida, tarmoq kompyuter zalida va boshqa sohalarda keng qo'llaniladi. Shaxsiy dizayn, do'stlikli odam-kompyuter interfeysi, o'qishga qulay lotin va ingliz tilidagi rangli ekran va holat belgilovchi interfeysi foydalanuvchilar uchun ishlatish va foydalanishni osonlashtiradi.

Mahsulot xususiyatlari

Aqliy raqamli nazorat texnologiyasi:
Tez ishlov beradigan mikrokontrollerlar va dasturlash mumkin bo'lgan logik qurilmalar orqali shema nazorati, parametrlarni sozlash, ish rejimi boshqarishi, avtomatik tekshirish va xato tahlili funksiyalari amalga oshiriladi. Barcha mustaqil shematik ulanishlarni avtomatik tekshirib, xatolarni tahlil qilish imkoniyati mavjud. Raqamli transformatsiya qilingan sinusoidal voltaj va sizning haqiqiy talablariga javob beradigan yangi yechimni ishonchli ravishda ishlatishingiz mumkin.)
Samarali IGBT (Insulated Gate Bipolar Transistor) inverter texnologiyasi:
IGBT ning yaxshi tez o'zgarish xususiyatlari; Yuqori voltaj va yuqori oqim bilan ishlash xususiyatlari; Voltaj tipidagi haydovchidan foydalaniladi, aniq aylanish uchun kam miqdordagi boshqaruv quvvati talab qilinadi. Beshinchi pokoleniya IGBT da pastroq doimiy voltaj pasayishi, yuqori inverter samaradorligi va yuqori ishonch darajasi mavjud.
Moslashuvchan parallel texnologiya:
Bitta mashina, 1+1 parallel va N+1 parallel taqsimotli tizimlarga mos keladi.
Yuqori yuk xususiyatlari:
Uchinchi bosqichda butunlay mustaqil PWM modulyatsiya va to'liq most IGBT inverter texnologiyasidan foydalaniladi, 0 dan 100% yukka qadar o'tishda bypasga o'tishni talab qilmasdan, toza va ishonchli chiqishni ta'minlaydi.
Insonga moslashtirilgan 7 duymli katta LCD ekran va lotin-va ingliz tilidagi rangli tanlovli ekran:
7 duymli katta LCD ekran, lotin va ingliz tillaridagi menularni namoyon etadi, aniq grafik diagramma orqali ish rejimini, o'zgaruvchan odam-kompyuter interfeysini ko'rsatadi. Tanlovli ekran orqali hodisalarni yozib olish va lotin va ingliz tillaridagi menular ishlatilishi mumkin.
To'liq himoya funksiyasi:
Ko'p xil tizim himoyasi va ogohlantirish funksiyalari, jumladan, kirish va chiqish voltajining yuqori bo'lganligi, kirishda yuzaga keladigan aniqlanmagan havo haroratining yuqori bo'lganligi, batarya juda to'ldirilib yoki ayrim paytlarda kam to'ldirilgandagi, chiqishda yuqori yuk va qisqa mazkurish, yuqori harorat.
Yuqori samarali dinamik xususiyatlar:
Aniq va effektiv qiymatlar kabi bir nechta feedback nazorat usullaridan foydalaniladi, bu orqali yuqori dinamik tushuntirish va voltaj deformatsiyasini kamaytirish amalga oshiriladi.
6 pulssiz (tanlovda 12 pulssiz)
Rectifier zaryad qiluvchi qurilma ham kirish harmonik filtri qo'shilgan, bu orqali kirish harmonik zararlarini samarali ravishda cheklash, UPS energiya ta'minotining kirish kvadratik koeffitsiyentini yaxshilash va kirish harmonik oqimini kamaytirish mumkin.
Aqliy batarya boshqaruv:
Aqliy batarya zaryad qilish, foydalanuvchining batarya konfiguratsiyasiga qarab avtomatik ravishda batarya zaryad parametrlarini sozlash, tengsiz va suyuqlik zaryadlarini o'zgartirish, harorat kompensatsiyasi zaryad qilish, energiya ta'minot muhitiga asosan zaryadni boshqarish, batarya ish muddatini uzaytirish va boshqaruvchilar ustiga tortiladigan vazifalarni kamaytirish.
To'liq ajralish texnologiyasi
Kirish va chiqish to'liq ajralish, bu orqali harmonik oqim va tarmoq energiyasidan to'g'ridan-to'g'ri ta'sirni kamaytirish.
Aqliy aloqa boshqaruv:
RS232 va RS485 aloqa portlari aniq multi-qolda aloqa va masofaviy kuzatuvni amalga oshiradi. Tanlov SNMP kartasi orqali masofaviy kuzatish va tarmoq boshqarish, tanlov passiv kontaktli interfeys orqali UPS holatini kuzatish mumkin.

Texnik xususiyatlari

Model HBS-6KS HBS-10KS HBS-15KS HBS-20KS HBS-30KS HBS-40KS HBS-50KS HBS-60KS HBS-80KS HBS-100KS HBS-120KS HBS-150KS HBS-200KS HBS-250KS HBS-300KS HBS-400KS
Nominal Capacity (kVA) 6 10 15 20 30 40 50 60 80 100 120 150 200 250 300 400
Overall Working Mode and Principle Online Power Supply, Static Bypass Switch (Uninterrupted Switching), Double Conversion Technology, Output Power Fully Isolated
Rectifier Working Mode 6-pulse (12-pulse Optional) Rectification

Input  
Phase Number

Three Phase + N + G

Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Voltage Harmonic Distortion < 5%
Soft Start 0-100% 5S
Nominal Output DC Voltage 405VDC
Rated Power (KW, Cosφ=0.8) Nominal Power × 0.8
Inverter  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 1% (Stable Load), 380VAC ± 5% (Load Fluctuation)
Nominal Frequency 50Hz ± 0.5%, 60Hz ± 0.5% (Battery Power Supply)
Frequency Stability < ± 0.5% (Asynchronous)
Frequency Tracking Range 50Hz ± 5%
Crest Factor 3:1
Output Waveform Sine Wave
Output Waveform Distortion Linear Load < 3%; Non-linear Load < 5%
Dynamic Load Voltage Transient < ± 5% (0 to 100% Load Change)
Instantaneous Recovery Time < 10ms
Overload Capacity 125% 1min, 150% 1s
Inverter Efficiency ≥95% (100% Load)
Bypass  
Phase Number Three Phase + N + G
Nominal Voltage 380VAC ± 25%
Nominal Frequency 50Hz ± 5%, 60Hz ± 5%
Conversion Time 0ms (Inverter/Bypass)
Battery Charging  
Battery Type Maintenance-free Lead-acid Battery
Maximum Output Voltage 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 220vdc/405vdc 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC 405VDC
Microcomputer-set Charging Current 1A~100A (Set According to Battery Capacity, Automatically Adjusted to 0.1C)
Quantity Unit 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 16 cells/30 cells 12V in series 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series) 30 cells/12V in series (180 cells/2V in series)
Charging Current 1A~100A (Automatically Adjusted to 0.1C According to Battery Capacity)
Nominal Battery Voltage 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 192VDC/360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC 360VDC
Float Voltage 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 220VDC/405VDC 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC) 405VDC (Battery Equalization Once Every 3 Months, Charging Voltage 435VDC)
Efficiency > 80% (100% Load)
System  
Computer Communication Interface Standard RS232, Optional RS485, Dry Contact, SNMP Remote Monitoring Network Adapter
Operating Temperature 0-40℃
Relative Humidity (No Condensation) 30% - 90%
Operating Altitude (Maximum) < 1000 meters (Power Drops by 1% for Every 100 Meters Increase, Maximum 4000 Meters)
Cooling Method Temperature-controlled Forced Air Cooling
Noise dB (1m from the Machine, Depending on Load and Temperature) 40-50 40-50 45-55 45-55 50-55 50-55 55-65 55-65 55-65 55-65 55-65 65-70 65-70 65-70 65-70 65-70
Cabinet Color Black (Optional)
Input Cable Bottom/Back
Easy Maintenance Top/Left/Right Sides Can Be Opened
External Dimensions W×D×H(mm) 390×660×860 450×725×1035 710×720×1450 710×850×1500 1100×860×1680 1100×860×1680 1500×1160×1800 1500×1160×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800 1800×1250×1800
Weight (kg) 150 212 260 352 396 485 568 635 903 951 1052 1355 1586 1850 2170 3155
Input and Output Devices Terminal Block
FAQ for
Q: Bu, yuqori chastotali 3-fazalik onlayn UPS bilan solishtirganda qanday afzalliklarga ega?
A:

Yuqori chastotali UPS bilan solishtirganda, bu o'ziga xos afzalliklarga ega: ① Yuqori ishonchli: Past chastotali transformator kuchli yuqoriga yuklanish imkoniyatiga (125% yuqoriga yuklanishni 10 daqiqaga qo'llab-quvvatlaydi) va himoya qilish imkoniyatiga ega; ② Yaxshi barqarorlik: Katta elektr energiyasi o'zgarishlari va yuqori garmoniklar bilan aniqlangan qattiq san'oiy mohit uchun mos; ③ Uzoq ish muddati: Past chastotali komponentlar kam issiqlik chiqaradi va sur'ash, ish muddati 10-15 yil bo'lganida; ④ Kuchli yukka moslashuvchanlik: Induktiv, kapasitiv va omli yuklarga (masalan, elektr motorlari, inversorlar) mos keladi.

Q: 3 fazli kirish va 3 fazli chiqishga ega bo'lgan past chastotali onlayn UPS ning asosiy funktsiyasi va ishlash printsipi nima?
A:

Asosiy funktsiyasi - bezaralashsiz, o'zgarishsiz va tooziqtas energiya ta'minlashi uchun yuqori quvvatli sanoat yuklariga, shuningdek, boshqaruv, garmonik filtratsiya va yopish xavfsizligi funksiyalariga ega. Ishlash printsipi ikki marta konvertatsiya (AC-DC-AC): elektr tarmog'i normalda, u 3-fazali AC ni DC ga aylantiradi, bataryani zaryad qiladi, keyin DC ni tik 3-fazali sinusoidal AC ga aylantiradi, yukni ta'minlash uchun; elektr tarmog'i rad etganda, u 0 ms o'tkazma vaqtida batarya energiyasiga o'tadi, yukni to'xtatishini ta'minlaydi.

Sizning taminotchilaringizni tanishang
Online do'kon
Vaqtida yetkazib berish darajasi
Reaksiya vaqti
100.0%
≤4h
Компания ҳақида кўриб чиқиш
Ish joyi: 1000m² Jamiy hodimlar soni: Eng yuqori yillik eksport (AQSh dollarida): 300000000
Ish joyi: 1000m²
Jamiy hodimlar soni:
Eng yuqori yillik eksport (AQSh dollarida): 300000000
Xizmatlar
Tadbirkor turi: Sotuv
Asosiy kategoriyalar: Jismlar qo'shimchasi/Tekshirish qurilmasi/Yuqori bo'lakli qurilmalar/Pastki elektr tarmog'i/Axborot uskunalari/Ishlab chiqarish uskunalari/Elektr tashkil etuvchi qurilma
Hayot davomida boshqaruv
Elektr jihozlarning xavfsiz ishlashi, uzluksiz nazorat va tashvishsiz elektr iste'moli uchun jihozlar sotib olish, foydalanish, ta'mirlash va keyingi sotuvdan keyingi xizmat ko'rsatish bo'yicha butun umrlik parvarish qilish xizmatlari
Uskuna etkazib beruvchisi platforma sifatidagi tasdiqnomani va texnik baholashni o'tkazgan bo'lib, manbadan boshlab mos kelish, mutaxassislilik va ishonchlilikni ta'minlaydi.

O'xshash mahsulotlar

O'quv materiallari

  • Asosiy transformator hodisalari va yengil gaz ishlayishi muammolari
    1. Kasalilik yozuvlari (19-mart, 2019)19-mart, 2019-yilda soat 16:13 da, monitoring fonida No. 3 asosiy transformatorining oq gaz harakati haqida xabar berildi. Elektr energiya transformatorlarini ishga tushirish qoidalari (DL/T572-2010) asosida, ekspluatatsiya va texnik xizmat ko'rsatish (E&TXK) xodimlari No. 3 asosiy transformatorning holatini tekshirdilar.Mazmunda tasdiqlandi: No. 3 asosiy transformatorining WBH elektrik emas himoya paneli B fazada transformatorning oq gaz harakati haqida
    02/05/2026
  • 10кВ распределитель линияларидаги бир фазали жерга уланиш ва уни бажарISH
    Bir fazali yer qo‘shilish xususiyatlari va aniqlash qurilmalari1. Bir fazali yer qo‘shilish xususiyatlariMarkaziy ogohlantirish signallari:Ogohlantirish chiqqonlari chalinadi va “[X] kV avtobus bo‘limi [Y] da yer qo‘shilishi” deb yozilgan ko‘rsatkich lampochkasi yonadi. Neytral nuqtasi Peterson spirali (yoyni bostirish spirali) orqali yerlangan tizimlarda “Peterson spirali ishlayapti” deb yozilgan ko‘rsatkich ham yonadi.Izolyatsiya nazorati voltmetri ko‘rsatkichlari:Avari
    01/30/2026
  • 110kV~220kV elektr tarmoqlarining transformatorlarining neutral nuqtasini qurilish rejimi
    110kV~220kV elektr tarmoqlarining transformatorlari uchun neutral nuqtaning yerdan ulash rejimlari, transformatorlar neutral nuqtasining izolyatsiya talablarni qanoatlantirishi kerak va substantsiyalarning nol-sekvans impedansini asosan o'zgartirmaydigan holda, tizimning har qanday qisqartma nuqtasidagi nol-sekvans umumiy impedansining musbat-sekvans umumiy impedansidan uch marta ortiq bo'lmaganiga ishonch hosil qilish kerak.Yangi tiklanish va texnologik takomillashtrish loyihalarida 220kV va 11
    01/29/2026
  • Nega Mavjudiyatlar Taşlar Shosheva va Zanjirli Toshdan Foydalanishini Sababini Nima?
    Substationlarda nima uchun tosh, kum, kivach va zavodlangan tosh ishlatiladi?Substationlarda, elektr energiyasi va taqsimot transformatorlari, uzatish liniyalari, voltaj transformatorlari, ampermetrlar va o'chirish shalterlari kabi jihozlar qo'shilish lozim. Qo'shilishdan tashqari, endi tosh va zavodlangan tosh substationlarda ko'pincha ishlatilishi sabablarini yuqori darajada tahlil qilamiz. Ular oddiy ko'rinadigan bo'lsa-da, bu toshlar xavfsizlik va funktsional vazifalarda muhim rol o'ynaydi.S
    01/29/2026
  • Nega qanday sababdan transformatorning markazi faqat bitta nuqtada grounding qilinishi kerak? Bir nechta nuqtalik grounding emasmi ko'proq ishonchli bo'ladimi?
    Transformerning markasi nima sababdan qurilishiga muhtoj?Ishlash jarayonida, transformerning markasi, shu bilan birga markani va spirlarini qamrab turuvchi metall konstruksiyalar, qismlar va komponentlar guvohlikli elektr maydoni ichida joylashgan. Bu elektr maydonining ta'siri ostida ular yer nisbatan nisbiy aniq potentsialni o'zlashtiradi. Agar marka qurilmagan bo'lsa, marka va qurilgan qamrab turuvchi konstruksiyalar va rezervuar orasida potentsial farqi bo'lib qolishi mumkin, bu esa bevosita
    01/29/2026
  • Transformer Noytral Tarmoqlanishini Tushunish
    I. Noytral nuqta nima?Transformatorlarda va generatorlarda noytral nuqta - bu o‘zgaruvchidan har bir tashqi terminalga qadar mutlaq voltaj teng bo'lgan qatordan xususiy nuqta. Quyidagi diagrammadagi O nuqtasi noytral nuqtani ifodalaydi.II. Noytral nuqtaga qanday qilib zamin beriladi?Uch fazali AC elektr tarmog‘idagi noytral nuqta va erkin maydon orasidagi elektr tarmoqlanish usuli noytral zaminlanish usuli deb ataladi. Bu zaminlanish usuli to‘g‘ridan-to‘g‘ri ta'sir etadi:Elektr tarmog‘ining xavf
    01/29/2026
To'g'ri tashkilotni topa olmadingizmi Yetakchi tasdiqlangan tashkilotlar sizni topishsin Hozir soʻrovnoma olish
To'g'ri tashkilotni topa olmadingizmi Yetakchi tasdiqlangan tashkilotlar sizni topishsin
Hozir soʻrovnoma olish
So'rov
+86
Faylni yuklash uchun bosing
Yuklab olish
IEE Business ilovalarini olish
IEE-Business ilovasini ishlatib jihozni qidirish orqali yechimlarni oling muvaffaqiyatlari bilan bog'laning va istalgan joyda va vaqtda sohaniy hamkorlikka qatnashing kuchli elektr energetika loyihalaringiz va biznesingiz rivojlanishi uchun