Yuqori chastota onlayn (rakka turi) uPs elektr energiyasi

  • High frequency on-line (rack type) UPS power supply

Asosiy xususiyatlari

Бренд Switchgear parts
Модель рақами Yuqori chastota onlayn (rakka turi) uPs elektr energiyasi
Chiqariladigan voltaj 110-127VAC
Kirish voltajining qiymati 110-127VAC
Ko'rsatkich 10kVA
Серия HBG

Taomatchilar tomonidan taqdim etilgan mahsulot tavsiflari

Tavsif

HBG seriyasi eng so'nggi texnologiyalarning asosiy qismini o'z ichiga oladi. Barcha qurilma dunyodagi qidiruvchan DSP raqamli boshqarish texnologiyasi va juda yuqori chastotali boshqarish texnologiyasidan foydalanadi. Bu, kichik hajmda, og'irlikda, yuqori samaradorlik bilan nol o'zgarish dizayni va toza sinusoidal chiqish texnologiyasini yaratadi, shuning uchun foydalanuvchining jihozlarining turli xil jihozlarga mos kelishi ta'minlanadi. Maxsus AC-DC o'zgarish skhemyasi o'tkazgich tok va voltajini tekshirish uchun ishlatiladi. Yuqori chastotali puls o'zgaruvchisi orqali kirish tokning signali voltajning signaliga moslashtiriladi, bu esa 95% dan yuqori kirish guvohligini ta'minlaydi. Oddiy holatda, o'tkazgich tok AC-DC skhemadan o'tkazilib, DCBUS DC voltajiga aylanadi, keyin inverter orqali 220V AC chiqishga aylanadi. Barcha yuklar tebranmalarini filtrlangan va chastotasini barqarorlagan toza sinusoidal energiya bilan ta'minlanadi. Eng yaxshi IGBT quvvat o'zgaruvchi element sifatida ishlatiladi. IGBT ning yuqori chastotali o'zgarish xususiyati orqali UPS inverterining ishlash chastotasi 40KH2 darajasiga yetishi mumkin, bu esa inverterning samaradorligini va UPSning umumiy samaradorligini oshiradi. Inverter chastotasining oshishi inverterning shovqinini kamaytiradi. Shuning uchun HBG seriyasi UPS-ni kompyuter xonada joylashtirish foydalanuvchingizning ishini ta'sir qilmaydi. Onlayn yuqori chastotali HBG seriyasi UPS RS232 suzuvchi interfeys orqali tarmoq serveriga ulanadi, bu esa tarmoq quvvatini doimiy ravishda monitoring qilish imkonini beradi. Bu, automatkik tekshirish, avtomatik saqlash, avtomatik vaqt bo'yicha yoqish/ochish, tarmoq holatini yozish kabi intellektual funksiyalarni amalga oshiradi, shunday qilib, odamlar va mashinalar orasidagi muloqotni ta'minlaydi. O'tkazgich tok kesildi holatda, UPS serverga xabar beradi, to'xtatishga tayyorlanadi, barcha ma'lumotlarni avtomatik ravishda saqlaydi va normal to'xtatish buyrug'ini bajaradi, bu esa aynan hech qanday nazorat yo'q tarmoq holatida ham tarmoq tizimining ma'lumotlar xavfsizligini ta'minlaydi.

Qo'llanish sohalar

Tarmoq boshqarish markazlari, kompyuter markazlari, bank va hisob-kitob, soliqlik, aloqa, pochta xizmatlari, radiotelevideniya, davlat himoyasi, transport, elektr energetika, sog'liqni saqlash, sanoat boshqarish va milliy himoya kabi muhim ma'lumot sohalarida keng qo'llaniladi.

Texnik parametrlar

Model HBG - 1KR (S) HBG - 2KR (S) HBG - 3KR (S) HBG - 6KR(S) HBG - 10KR(S)
Phase Single Phase Input and Output Single Phase Input and Output Single Phase Input and Output Single Phase Input and Output Single Phase Input and Output
Capacity 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 W
Input          
Input Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Range 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load 110-300VAC ±3% at 50% load; 176-300 VAC ±3% at 100% load
Frequency Range 40Hz ~ 70 Hz 40Hz ~ 70 Hz 40Hz ~ 70 Hz 40Hz ~ 70 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Power Factor ≥ 0.99@100% load ≥ 0.99@100% load ≥ 0.99@100% load ≥ 0.99@100% load ≥ 0.99@100% load
Output          
Output Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Regulation (Battery Mode) ±1% ±1% ±1% ±1% ±1%
Frequency Range (Synchronous Correction Range) 47 ~ 53 Hz or 57 ~ 63 Hz 47 ~ 53 Hz or 57 ~ 63 Hz 47 ~ 53 Hz or 57 ~ 63 Hz 47 ~ 53 Hz or 57 ~ 63 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Frequency Accuracy (Battery Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1 3:1 3:1 3:1 3:1
Harmonic Distortion ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load)
Conversion Time          
AC to DC None None None None 0 ms
Inverter to Bypass 4 ms (Standard Conditions) 4 ms (Standard Conditions) 4 ms (Standard Conditions) 4 ms (Standard Conditions) 0 ms
Waveform (Battery Mode) Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave
Efficiency          
Mains Mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
Battery          
Standard Unit          
Battery Model 12V / 9AH 12V / 9AH 12V / 9AH 12V / 9AH 12V / 9AH
Quantity (Cells) 2 4 6 16 20
Standard Charging Time - 4 hours to 90% - 9 hours to 90% -
Maximum Charging Current - 1.0A (Max) - Preset:1.0A, Max:2.0A -
Charging Voltage 27.4VDC ±1% 54.7VDC ±1% 82.1VDC ±1% 218.4VDC ±1%
 
273VDC ±1%
 
218.4VDC ±1%
 
273VDC ±1%
-
Long-term Unit          
Battery Model - - Depends on Power Supply Time Depends on Power Supply Time -
Quantity (Cells) 2
 
3
4 6
 
8
16-20 Grain (adjustable) -
Maximum Charging Current - 1.0A,2.0A,4.0A,6.0A - 1.0A, 2.0A, 4.0A, 6.0A (adjustable, 6A only applicable to 16 batteries) -
Charging Voltage 27.4VDC ±1%
 
41.0VDC ±1%
54.7VDC ±1% 82.1VDC ±1%
 
82.1VDC ±1%
109.4VDC±1%
 
218.4VDC ±1% (Based on 16 pieces)
-
Appearance          
LCD or LED Display Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication
Alarm          
Battery Mode Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds Beeps every 4 seconds
Low Battery Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second
Overload Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second Beeps every 1 second
Error Continuous Beep Continuous Beep Continuous Beep Continuous Beep Continuous Beep
External Dimensions          
Standard Unit          
Dimensions (W×D×H)mm 310 X 438 X 88 410 X 438 X 88 630 X 438 X 88 host:530 X 438 X 88【2U】
 
battery box:438 X 530 X 668 X 438 X 88【2U】
 
battery box:61
host:580 X 438 X 133【3U】
 
battery box:580 X 438 X 133【3U】
Net Weight (kg) 9.9 16.9 25.6 host:135
 
battery box:61
 
500 X 438 X 88【2U】
 
15
host:18
 
battery box:61
 
580 X 438 X 133【3U】
 
18
Long-term Unit          
Dimensions (W×D×H)mm 310 X 438 X 88 410 X 438 X 88 - - -
Net Weight (kg) 5.5 8.1 8.5 - -
Operating Environment          
Temperature and Humidity Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) Relative Humidity 0-95% and Temperature 0-40°C (No Condensation)
Noise Less than 50dB@ 1m Less than 50dB@ 1m Less than 50dB@ 1m Less than 55dB @ 1m Less than 58dB @ 1m
Control Management          
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMP Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management Power Management Supports SNMP Management and Network Management

*Kogda UPS nastroen na rezhim postoyannogo napryazheniya i chastoty, vykhodnaya moshchnost' snizhaetsya na 40%. Kogda vykhodnoye napryazheniye UPS nastroyeno na 208VAC, vykhodnaya moshchnost' snizhaetsya na 10%.

**Kogda kolichestvo vnutrennikh batarey izmenyaetsya na 16-19, mashina snizhaet vykhod po sleduyushchey formule: P-PrtiX (N/20x100%).

***Yesli mashina ustanovlena na vysote, prevyshayushchey 1000 metrov, vykhodnaya moshchnost' snizhaetsya na 1% za kazhdyye 100 metrov povysheniya. Yesli proizoydut kakie-libo izmeneniya v tekushchikh spetsifikatsiyakh produkta, dopolnitel'noye soobshcheniye ne budet danno.

FAQ for
Q: Kak qoidalarga muvofiq yuqori chastotali onlayn (shkaf turli) UPS va uning batareyasini qanday o'zlashtirish mumkin?
A:

Qayta-qayta ishlatish nihoyasida UPS qismi va batareya o'zgartiriladi, shuningdek, xizmat ko'rsatish muddati uzaytiriladi: ① UPS qismi bo'yicha ishlar: - Oyiga bir marta: Aniq qilmab qolgan ovoz, juda issiq bo'lgan yoki ochib qolg'an ulkanlarni tekshirish; suyuqlikdan tozalash uchun kurka parchadan foydalaning; - Har to'rt oyda bir marta: Ventilyatorning ishlashini (qo'lga kelmaganligini), himoya funksiyalarini (yoqtirilish, ortiqcha voltaj) tekshiring; - Yillik: Kirish/chiqish voltajini, samaradorlikni va ichki komponentlarning (rectifier, inverter) ishlashini sinab ko'ring; ② Batareya bo'yicha ishlar: - Kurma-batareya: Terminalning korroziyasi (agar mavjud bo'lsa soda ashidalari yordamida tozalang), elektrolit darajasini (ochilmagan batareyalar uchun) tekshiring; har 3 oyda bir marta zaryad/tushum qiling, shunday qilib batareya sulfitlanishidan saqlaning; kapasiteti <80% miqdorda bo'lgan batareyalarni almashtiring; - Litium-ion batareya: O'tirishga yetkazmang/bo'shatmang; BMS ishini qoidalarga muvofiqlik bilan tekshiring; vosita-vaqtida xato batareya modullarini almashtiring; ③ Muhim eslatma: UPS ichki komponentlarini suv yoki kimyoviy tozaqilish vositalari yordamida tozalamang; ishni boshlash oldidan energiyani o'chiring va kondensatorlar tushum olishi uchun kuting (≥5 daqiqa).

Q: Yuqori chastotali onlayn (stend tipidagi) UPS ning asosiy funktsiyasi va ishlash printsipi nima?
A:

Bu IT jihozlari, ma'lumotlar markazlari va server xonalari uchun mo'ljallangan rakshtga o'rnatiladigan bekoq talqin energiyasi. Asosiy funksiyalari: ① Jihozlarni voltaj o‘zgarishidan, elektr energiyasining to'xtashi, aniqlik va garmoniklardan himoya qilish uchun stabi l, chist sinusoide energiya taqdim etish; ② Elektr energiyasining to'xtashida (batareya energiyasiga aniq o‘tish) nol vaqt bo'sh qolishini ta'minlash; ③ Rakshtga o'rnatishni qo'llab joyni saqlash. Ishlanish printsipi: Ikki marta o‘zgartirish (onlayn) texnikasini qo'llaydi — AC kiritma oldin DC ga (rektilaytor), keyin DC qayta stabi l AC ga (inverter) jihoz ishlatishi uchun o‘zgartiriladi; elektroenergiya to'xtaganda, batareya inverterga ko'proq tez (o‘tish vaqti <2ms) DC energiyani taqdim etadi, bu orqali davraovli energiya taqdim etiladi; yuqori chastota dizayni (20kHz~50kHz) UPS ni past chastotali modellardan kichikroq, yengilroq va energiyada samaraliroq qilib olib beradi.

Sizning taminotchilaringizni tanishang
Online do'kon
Vaqtida yetkazib berish darajasi
Reaksiya vaqti
100.0%
≤4h
Компания ҳақида кўриб чиқиш
Ish joyi: 1000m² Jamiy hodimlar soni: Eng yuqori yillik eksport (AQSh dollarida): 300000000
Ish joyi: 1000m²
Jamiy hodimlar soni:
Eng yuqori yillik eksport (AQSh dollarida): 300000000
Xizmatlar
Tadbirkor turi: Sotuv
Asosiy kategoriyalar: Jismlar qo'shimchasi/Tekshirish qurilmasi/Yuqori bo'lakli qurilmalar/Pastki elektr tarmog'i/Axborot uskunalari/Ishlab chiqarish uskunalari/Elektr tashkil etuvchi qurilma
Hayot davomida boshqaruv
Elektr jihozlarning xavfsiz ishlashi, uzluksiz nazorat va tashvishsiz elektr iste'moli uchun jihozlar sotib olish, foydalanish, ta'mirlash va keyingi sotuvdan keyingi xizmat ko'rsatish bo'yicha butun umrlik parvarish qilish xizmatlari
Uskuna etkazib beruvchisi platforma sifatidagi tasdiqnomani va texnik baholashni o'tkazgan bo'lib, manbadan boshlab mos kelish, mutaxassislilik va ishonchlilikni ta'minlaydi.

O'xshash mahsulotlar

O'quv materiallari

  • Asosiy transformator hodisalari va yengil gaz ishlayishi muammolari
    1. Kasalilik yozuvlari (19-mart, 2019)19-mart, 2019-yilda soat 16:13 da, monitoring fonida No. 3 asosiy transformatorining oq gaz harakati haqida xabar berildi. Elektr energiya transformatorlarini ishga tushirish qoidalari (DL/T572-2010) asosida, ekspluatatsiya va texnik xizmat ko'rsatish (E&TXK) xodimlari No. 3 asosiy transformatorning holatini tekshirdilar.Mazmunda tasdiqlandi: No. 3 asosiy transformatorining WBH elektrik emas himoya paneli B fazada transformatorning oq gaz harakati haqida
    02/05/2026
  • 10кВ распределитель линияларидаги бир фазали жерга уланиш ва уни бажарISH
    Bir fazali yer qo‘shilish xususiyatlari va aniqlash qurilmalari1. Bir fazali yer qo‘shilish xususiyatlariMarkaziy ogohlantirish signallari:Ogohlantirish chiqqonlari chalinadi va “[X] kV avtobus bo‘limi [Y] da yer qo‘shilishi” deb yozilgan ko‘rsatkich lampochkasi yonadi. Neytral nuqtasi Peterson spirali (yoyni bostirish spirali) orqali yerlangan tizimlarda “Peterson spirali ishlayapti” deb yozilgan ko‘rsatkich ham yonadi.Izolyatsiya nazorati voltmetri ko‘rsatkichlari:Avari
    01/30/2026
  • 110kV~220kV elektr tarmoqlarining transformatorlarining neutral nuqtasini qurilish rejimi
    110kV~220kV elektr tarmoqlarining transformatorlari uchun neutral nuqtaning yerdan ulash rejimlari, transformatorlar neutral nuqtasining izolyatsiya talablarni qanoatlantirishi kerak va substantsiyalarning nol-sekvans impedansini asosan o'zgartirmaydigan holda, tizimning har qanday qisqartma nuqtasidagi nol-sekvans umumiy impedansining musbat-sekvans umumiy impedansidan uch marta ortiq bo'lmaganiga ishonch hosil qilish kerak.Yangi tiklanish va texnologik takomillashtrish loyihalarida 220kV va 11
    01/29/2026
  • Nega Mavjudiyatlar Taşlar Shosheva va Zanjirli Toshdan Foydalanishini Sababini Nima?
    Substationlarda nima uchun tosh, kum, kivach va zavodlangan tosh ishlatiladi?Substationlarda, elektr energiyasi va taqsimot transformatorlari, uzatish liniyalari, voltaj transformatorlari, ampermetrlar va o'chirish shalterlari kabi jihozlar qo'shilish lozim. Qo'shilishdan tashqari, endi tosh va zavodlangan tosh substationlarda ko'pincha ishlatilishi sabablarini yuqori darajada tahlil qilamiz. Ular oddiy ko'rinadigan bo'lsa-da, bu toshlar xavfsizlik va funktsional vazifalarda muhim rol o'ynaydi.S
    01/29/2026
  • Nega qanday sababdan transformatorning markazi faqat bitta nuqtada grounding qilinishi kerak? Bir nechta nuqtalik grounding emasmi ko'proq ishonchli bo'ladimi?
    Transformerning markasi nima sababdan qurilishiga muhtoj?Ishlash jarayonida, transformerning markasi, shu bilan birga markani va spirlarini qamrab turuvchi metall konstruksiyalar, qismlar va komponentlar guvohlikli elektr maydoni ichida joylashgan. Bu elektr maydonining ta'siri ostida ular yer nisbatan nisbiy aniq potentsialni o'zlashtiradi. Agar marka qurilmagan bo'lsa, marka va qurilgan qamrab turuvchi konstruksiyalar va rezervuar orasida potentsial farqi bo'lib qolishi mumkin, bu esa bevosita
    01/29/2026
  • Transformer Noytral Tarmoqlanishini Tushunish
    I. Noytral nuqta nima?Transformatorlarda va generatorlarda noytral nuqta - bu o‘zgaruvchidan har bir tashqi terminalga qadar mutlaq voltaj teng bo'lgan qatordan xususiy nuqta. Quyidagi diagrammadagi O nuqtasi noytral nuqtani ifodalaydi.II. Noytral nuqtaga qanday qilib zamin beriladi?Uch fazali AC elektr tarmog‘idagi noytral nuqta va erkin maydon orasidagi elektr tarmoqlanish usuli noytral zaminlanish usuli deb ataladi. Bu zaminlanish usuli to‘g‘ridan-to‘g‘ri ta'sir etadi:Elektr tarmog‘ining xavf
    01/29/2026
To'g'ri tashkilotni topa olmadingizmi Yetakchi tasdiqlangan tashkilotlar sizni topishsin Hozir soʻrovnoma olish
To'g'ri tashkilotni topa olmadingizmi Yetakchi tasdiqlangan tashkilotlar sizni topishsin
Hozir soʻrovnoma olish
So'rov
+86
Faylni yuklash uchun bosing
Yuklab olish
IEE Business ilovalarini olish
IEE-Business ilovasini ishlatib jihozni qidirish orqali yechimlarni oling muvaffaqiyatlari bilan bog'laning va istalgan joyda va vaqtda sohaniy hamkorlikka qatnashing kuchli elektr energetika loyihalaringiz va biznesingiz rivojlanishi uchun