| Handelmerk | Switchgear parts |
| Modelnommer | Hoë frekwensie aanlyn UPS voorsiening (3Fase In 1Fase Uit) |
| Gedraaide frekwensie | 50/60Hz |
| Uitvoer-spanning | 208-240VAC |
| Kapasiteit | 20kVA |
| Reeks | HBGD |
Die HBGD-reeks UPS-kapasiteit sluit 10KVA/15KVA/20KVA in, drie-invoer enkelvoudige fase uit, hierdie reeks produkte maak gebruik van 'n dubbeltransformer puur in-tipe argitektuur, is die mees effektiewe oplossing vir alle kragvoorsieningsprobleme argitekturele ontwerp, Vir die kragnetwerk: kraguitval, hoofspanning is te hoog of te laag, spanningsverandering of dempingsslag, hoëspanningspuls, spanningsfluktuasie, harmoniese distorsie, kluterstoring, frekwensiefluktuasie en ander toestande kan 'n goeie oplossing bied. om veilige en betroubare kragvoorsiening vir die gebruiker se belasting te verskaf.
Tegniese eienskappe
Ware aanlyn dubbele omskakelingUltra wyd hoofspanningsinvoer bereik (190V-520V)Die uitsetfrekwensie kan opsioneel aangepas word na 50Hz/60HZNoodkrag afsluiting (EPO)Vergelykbare motor kragvoorsieningNoodkrag afsluiting (EPO)SNMP+USB+RS-232 multipl monitoringOff-line Onderhoudsontwerp (Opsioneel)
Toepassingsgebied
Gepas vir klein en middelgroot datacenters, onderneming serverkamers, beheercentra in vervaardiging, vervoer, energie en ander velde, asook presisieproduksie en toetsapparatuur vir industriële velde soos SMT oppervlakmonteerapparate, as sleutelapparatuur vir kragvoorsiening en beskerming.
Tegniese Parameters
| Model Specification | HBGD-10KH(S) | HBGD-15KH(S) | HBGD-20KS |
|---|---|---|---|
| Phase | Three-Phase Single-Phase Output | Three-Phase Single-Phase Output | Three-Phase Single-Phase Output |
| Capacity | 10000 VA / 8000 W | 15000 VA / 12000 W | 20000 VA / 16000 W |
| Input | |||
| Rated Voltage | 3 × 400 VAC (3Ph+N) | 3 × 400 VAC (3Ph+N) | 3 × 400 VAC (3Ph+N) |
| Voltage Range | 305-520 VAC (3-phase @ 100% load); 190-520 VAC (3-phase @ 50% load) | 305-520 VAC (3-phase @ 100% load); 190-520 VAC (3-phase @ 50% load) | 305-520 VAC (3-phase @ 100% load); 190-520 VAC (3-phase @ 50% load) |
| Frequency Range | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz | 46~54 Hz or 56~64Hz |
| Output | |||
| Output Voltage | 208/220/230/240VAC | 208/220/230/240VAC | 208/220/230/240VAC |
| Voltage Range (Battery Mode) | ± 1% | ± 1% | ± 1% |
| Frequency Range (Synchronous Correction Range) | 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz | 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz | 46~54 Hz ◎ 50 Hz / 56~64 Hz ◎ 60 Hz |
| Frequency Range (Battery Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Surge Ratio (Max) | 3:1 | 3:1 | 3:1 |
| Harmonic Distortion | ≤ 3% THD (Linear Load); ≤ 5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤ 5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤ 5% THD (Non-linear Load) |
| Conversion Time | |||
| AC to DC | 0 ms | 0 ms | 0 ms |
| Inverter to Bypass | 0 ms | 0 ms | 0 ms |
| Waveform (Battery Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
| Efficiency | |||
| Mains Mode | 91% | 91% | 91% |
| Battery Mode | 91% | 91% | 91% |
| Battery | |||
| Standard Unit | |||
| Battery Model | 12 V / 9 AH | 12 V / 9 AH | 12 V / 9 AH |
| Quantity (Cells) | 16 | 20 × 2 (18~20 Adjustable) | - |
| Standard Charging Time | - | 9 hours to 90% | - |
| Maximum Charging Current | 1A | 2A | - |
| Charging Voltage | 218.4 VDC ± 1% | 273 VDC ± 1% | - |
| Long-term Unit | |||
| Battery Model | - | Depends on Power Supply Time | - |
| Quantity (Cells) | 16 | 20 | - |
| Maximum Charging Current | - | Preset 2A, 1A/2A/4A/6A Adjustable | - |
| Charging Voltage | 218.4 VDC ± 1% | 273 VDC ± 1% (Based on 20 Batteries) | - |
| Display Description | |||
| LCD or LED | System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication | System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication | System Status, Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Input/Output Voltage, Fault Indication |
| Alarm Sound | |||
| Battery Mode | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds |
| Low Battery | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second |
| Overload | Beeps every 0.5 second | Beeps every 0.5 second | Beeps every 0.5 second |
| Error | Continuous Beep | Continuous Beep | Continuous Beep |
| Physical Performance | |||
| Standard Unit | |||
| Dimensions (W×D×H)mm | 190×442×688 | 190×442×688 | 190×575×688 |
| Net Weight (kgs) | 65 | 78 | 80.1 |
| Long-term Unit | |||
| Dimensions (W×D×H)mm | 190×442×318 | 190×575×318 | 190×575×318 |
| Net Weight (kgs) | 15 | 19 | 19 |
| Operating Environment | |||
| Temperature and Humidity | - | Relative Humidity 0-90% and Temperature 0-40°C (No Condensation) | - |
| Noise | Less than 58dB@1m | Less than 60dB@1m | - |
| Control Management | |||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
| Optional SNMP | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management |
*Wanneer die UPS ingestel is op konstante spannings- en frekwensiemodus, sal die uitsetvermoën met 40% verminder word. Wanneer die uitsetspanning van die UPS ingestel is op 208VAC, sal die uitsetvermoën met 10% verminder word.
**Indien die toestel geïnstalleer word by 'n hoogte wat 1000 meter oorskry, sal die uitsetvermoën met 1% per 100 meter in hoogte verminder.
*S stel langdurige modelle voor
*Indien daar enige veranderinge aan die huidige produkspesifikasies is, sal geen verdere kennisgewing gegee word nie