Indoor AC high-voltage vacuum load break switch

  • Indoor AC high-voltage vacuum load break switch

Key attributes

Brand ROCKWILL
Model NO. Indoor AC high-voltage vacuum load break switch
Rated voltage 12kV
Rated normal current 200A
Rated frequency 50/60Hz
Series FZN

Product descriptions from the supplier

Description

Product Overview

 Indoor AC high-voltage vacuum load switch (hereinafter referred to as load switch) is suitable for three-phase AC 50Hz, 12kV power supply network, as a break load current and close short-circuit current. The product can be equipped with manual and motor operating mechanisms, especially suitable for places with severe conditions, long maintenance cycles and frequent operation requirements.
Vacuum load switch-fuse combination with fuse (hereinafter referred to as combination appliance) FZRN25A-12(D)/T200-31.5 can break the short-circuit current for short-circuit protection. The product has a mechanism tripping, equipped with a fuse with an impactor, when passing the overload current or short-circuit current, the fuse is blown, and the impactor hits the tripping device to make the load switch automatically open to avoid phase loss operation.

Key Features

  • High - efficiency Arc Extinction and Breaking Capacity:Leveraging the high insulation strength and rapid arc - extinction characteristics of the vacuum interrupter, it can quickly extinguish the arc and reliably break load currents, overload currents, and even short - circuit currents under certain conditions. This significantly reduces the ablation of the contacts by the arc and extends the electrical service life of the equipment. For example, in a frequently operated power distribution system, it can stably perform circuit switching operations, reducing the probability of failures.

  • High Insulation Performance:The vacuum environment itself has extremely high insulation performance. Coupled with a reasonable insulation structure design, the indoor AC high - voltage vacuum load break switch can operate reliably in high - voltage environments, effectively preventing phase - to - phase and phase - to - ground short circuits and ensuring the safety and stability of the power system.

  • Fast Switching:Equipped with an advanced operating mechanism, it can achieve fast switching operations with short switching times. It can quickly isolate faulty circuits, reducing the impact of faults on the system. For instance, in the event of a short - circuit fault, it can rapidly cut off the circuit, limit the duration of the short - circuit current, and reduce the risk of equipment damage.

Technical Parameters

 Operating Environmental Conditions

  • Ambient Air Temperature: Maximum +40°C, Minimum -10°C

  • Altitude: Not exceeding 1000m

  • Relative Humidity: Daily average not greater than 95%, Monthly average not greater than 90%

  • Seismic Intensity: Less than Grade 8

  • Ambient Air Shall Be Free from Pollution by Corrosive, Flammable Gases, Water Vapor and Other Harmful Gases

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.