• IEEE Type Tee Connector
IEEE Type Tee Connector
discuss personally
Model
RW-QJT-12/20/600A
RW-QJT-8.7/15/600A
Basic info
Brand Switchgear parts
Model NO. IEEE Type Tee Connector
Rated voltage 8.7/15kV
Rated normal current 600A
Series RW-QJT
Product Detail

Summary

Shielding 630A IEEE type Tee connector, directly connect to the bushing of switchgear and the wall bushing of cable branch box.provide fully insulated safety circuits for Switch cabinets and cable branch boxes. The tail can be plugged directly with insulating plugs, but also extend the connection after the connection- Head or rear connector with surge arrester. Through 630A prefabricated joints to achieve single-phase or three-phase insulated cables and transformers, switchgear, branch boxes and other equipment connected. The products is suitable for indoor and outdoor installation, continuous rated current is 630A (900A overload for 8 hours). When the product is fitted with a suitable bushing or plug, a fully shielded and hermetically separable connection is provided. Long-term underwater and others- Harsh conditions of operation.For cross-section of the cable cross-section of 25mm² ~ 40Omm² XLPE cable.

Model & Specification

Applicable highest voltage

Rated current

Cross-section of cable     mm2

 Applicable range of Outside diameter of insulation of cable  (mm)

QJT-15/600-50

8.7/15kV

600A

25~50

Φ16~Φ20

QJT-15/600-95

8.7/15kV

600A

70~95

Φ20~Φ23

QJT-15/600-195

8.7/15kV

600A

120~150

Φ23~Φ26

QJT-15/600-240

8.7/15kV

600A

185~240

Φ26~Φ30.5

QJT-15/600-400

8.7/15kV

600A

300~400

Φ30.5~Φ35

QJT-20/600-35

12/20kV

600A

35

Φ18~Φ20

QJT-20/600-70

12/20kV

600A

50~70

Φ20~Φ23

QJT-20/600-120

12/20kV

600A

95~120

Φ23~Φ26

QJT-20/600-185

12/20kV

600A

150~185

Φ26~Φ30.5

QJT-20/600-300

12/20kV

600A

240~300

Φ30.5~Φ35

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the methods for handling single-phase grounding faults in the small-current grounding system of the distribution network?
What are the methods for handling single-phase grounding faults in the small-current grounding system of the distribution network?
Current Status of Single-Phase Grounding Fault DetectionThe low accuracy of single-phase grounding fault diagnosis in non-effectively grounded systems is attributed to several factors: the variable structure of distribution networks (such as looped and open-loop configurations), diverse system grounding modes (including ungrounded, arc-suppression coil grounded, and low-resistance grounded systems), the increasing annual ratio of cable-based or hybrid overhead-cable wiring, and complex fault typ
Leon
08/01/2025
Neutral line current is actually greater than live line current? Why?
Neutral line current is actually greater than live line current? Why?
In a three-phase four-wire power distribution system, it is a consensus among industry insiders that the neutral line current should be very small when the three-phase loads are balanced. However, more and more phenomena are subverting this concept.For example, the advertising light boxes around a building use fluorescent lighting with electronic ballasts. The loads on the three-phase lines are balanced, with each phase current being approximately 90A, but the neutral line current reaches 160A.I
RW Energy
08/01/2025
Difference Between EMF and Voltage
Difference Between EMF and Voltage
One of the key differences between electromotive force (EMF) and voltage is that EMF refers to the energy supplied to charges, while voltage represents the energy required to move a unit charge from one point to another. Other distinctions between the two are detailed in the comparison chart below.Comparison ChartDefinition of VoltageVoltage is defined as the energy required to move a unit charge from one point to another. It is measured in volts (V) and denoted by the symbolV. Voltage is induce
Dyson
08/01/2025
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Currently, the market price of copper remains high, fluctuating in the range of 70,000 to 80,000 yuan per ton. In contrast, the price of aluminum stays low, lingering in the range of 18,000 to 20,000 yuan per ton. For power transformers, replacing copper windings with aluminum windings in design will undoubtedly significantly reduce the material cost of products, bringing substantial cost savings to end customers.For a long time, it has been widely believed in the industry that aluminum windings
Ron
08/01/2025
What should be done if the neutral line current is too large?
What should be done if the neutral line current is too large?
As we all know, if an electrical line exceeds its rated load, it will overheat severely, and may even cause a fire. For safety reasons, overcurrent protection devices are therefore installed on lines. Whenever the current in the line exceeds the rated value, the overcurrent protection device will automatically cut off the line to prevent fire. The "excessive neutral line current" mentioned here refers to the phenomenon where the neutral line current is excessively high (more than 1.5 times the p
RW Energy
08/01/2025
What does the lifting inspection of a transformer core include?
What does the lifting inspection of a transformer core include?
1.Environmental Requirements for Transformer Core-Lifting Inspection1.1 General Environmental ConditionsCore - lifting operations are preferably carried out indoors. For large transformers that have to be operated outdoors due to specific conditions, sufficient measures must be taken to prevent moisture and dust contamination.Core - lifting should not be conducted during rainy or snowy weather or when the relative humidity exceeds 75%.The ambient air temperature during core - lifting should not
Rockwell
08/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!