• IEC Type Tee connector
  • IEC Type Tee connector
  • IEC Type Tee connector
IEC Type Tee connector
discuss personally
Model
RW-QCBT-35/630A
RW-QCBT-24/630A
RW-QCBT-12/630A
Basic info
Brand Switchgear parts
Model NO. IEC Type Tee connector
Rated voltage 24kV
Rated normal current 630A
Series RW-QCBT
Product Detail

Summary
Shielding 630A IEC type Tee connector, directly connect to the bushing of switchgear and the wall bushing of cable branch box.provide fully insulated safety circuits for Switch cabinets and cable branch boxes. The tail can be plugged directly with insulating plugs, but also extend the connection after the connection Head or rear connector with surge arrester. Through 630A prefabricated joints to achieve single-phase or three-phase insulated cables and transformers, switchgear, branch boxes and other equipment connected. The products is suitable for indoor and outdoor installation, continuous rated current is 630A (900A overload for 8 hours). When the product is fitted with a suitable bushing or plug, a fully shielded and hermetically separable connection is provided. Long-term underwater and others Harsh conditions of operation. For cross-section of the cable cross-section of 25mm² ~630mm² XLPE cable.

Standard packing
Body of Tee connector
Silicone grease、towels
Stress cone
Instruction Manual
Positioning chain, Phase ribbon
nInsulating plug (incude Semi-conductive end cap)
Handles, gauze
Dust cap
Terminals
Rulers for installation
Bolt stud
Conformity certificat

Technical specification

Item

Parameter

Rate voltage

12kV                         24kV                     35kV

Rate current

630A                         630A                     630A

Power frequency withstand voltage for 1 min

42Kv                         54kv                      117kv

Impulse voltage (10 times of positive and negative polarity)

95kV                         125kV                    200kV

Partial discharge

       15kV,≤10pC               21kV,≤10pC            45kV,≤10pC

Shielding resistance

≤5000Ω

Ordering information

   Product model

RW-QCBT 12kV-630A-25mm²       RW-QCBT 24kV-630A-25mm²       RW-QCBT 35kV-630A-25mm²

RW-QCBT 12kV-630A-35mm²       RW-QCBT 24kV-630A-35mm²       RW-QCBT 35kV-630A-35mm²

RW-QCBT 12kV-630A-50mm²       RW-QCBT 24kV-630A-50mm²       RW-QCBT 35kV-630A-50mm²

RW-QCBT 12kV-630A-70mm²       RW-QCBT 24kV-630A-70mm²       RW-QCBT 35kV-630A-70mm²

RW-QCBT 12kV-630A-120mm²      RW-QCBT 24kV-630A-120mm²      RW-QCBT 35kV-630A-120mm²

RW-QCBT 12kV-630A-150mm²      RW-QCBT 24kV-630A-150mm²      RW-QCBT 35kV-630A-150mm²

RW-QCBT 12kV-630A-185mm²      RW-QCBT 24kV-630A-185mm²      RW-QCBT 35kV-630A-185mm²

RW-QCBT 12kV-630A-240mm²      RW-QCBT 24kV-630A-240mm²      RW-QCBT 35kV-630A-240mm²

RW-QCBT 12kV-630A-300mm²       RW-QCBT 24kV-630A-300mm²      RW QCBT 35kV-630A-500mm²

RW-QCBT 12kV-630A-400mm²       RW-QCBT 24kV-630A-400mm²      RW-QCBT 35kV-630A-500mm²

RW-QCBT 12kV-630A-500mm²       RW-QCBT 24kV-630A-500mm²       RW-QCBT 35kV-630A-500mm²

                                                         RW-QCBT 24kV-630A-630mm²       RW-QCBT 35kV-630A-630mm²

 

Note: Selection should depend on the outside diameter of insulation of cable, the cable cross-section only for reference

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the accident scenarios in a substation?
What are the accident scenarios in a substation?
Handling of Minor Action of Transformer Gas RelayImmediately check and record the protective relay action signals, and report to the dispatcher and station manager.Closely monitor the transformer’s voltage, current, temperature, oil level, oil color, sound, and cooler operation, and assign personnel to conduct an external inspection of the transformer.If significant abnormalities are found during the inspection, report to the dispatcher and take the faulty transformer offline. If no obviou
Leon
07/30/2025
Power System Voltage Level Classification
Power System Voltage Level Classification
What Is a Voltage Class?Definition of Voltage Class:Voltage classes (or voltage levels) refer to a set of standardized rated voltages used in power systems and electrical equipment. A rated voltage is the nominal voltage at which equipment is designed to operate under normal conditions; essentially, a voltage class defines the intended working voltage range for a system or device.Analogy to Consumer Appliances:Household appliances (e.g., refrigerators, TVs) operate at a nominal voltage—typ
Vziman
07/30/2025
What is the reason for conducting five impulse tests before commissioning a transformer?
What is the reason for conducting five impulse tests before commissioning a transformer?
Verification of Insulation IntegrityWhen a new or overhauled transformer is energized under open-circuit (no-load) conditions, switching surges—caused by operations such as opening or closing the no-load transformer circuit—can generate overvoltages. These reach 4.0–4.5 times the phase voltage if the neutral point is isolated or earthed through a Petersen coil, and up to 3.0 times the phase voltage when the neutral is solidly grounded. The full-voltage, no-load impact test deli
Rockwell
07/30/2025
Analysis of the Causes of Large - scale Failures of Surge Arresters in 10 kV Distribution Lines
Analysis of the Causes of Large - scale Failures of Surge Arresters in 10 kV Distribution Lines
1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
Leon
07/30/2025
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer.Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source.Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs).Process Layer: Features monitoring terminals for Potential Transformers (PTs) and
Oliver Watts
07/30/2025
Improvement and Application of the Test Device for Surge Arrester Online Monitor
Improvement and Application of the Test Device for Surge Arrester Online Monitor
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Efficienc
Edwiin
07/30/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!