H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer

  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
  • H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer

Key attributes

Brand Vziman
Model NO. H59 H61 20kV 30kV 33kV High Voltage Oil Immersed Toroidal Power Transformer
Rated voltage 33kV
Rated frequency 50/60Hz
Rated capacity 400kVA
Series S

Product descriptions from the supplier

Description

Product Description

The H59/H61 33/0.41kV pole-mounted high-voltage oil-immersed toroidal transformer is a premium three-phase power distribution solution tailored for industrial and civil grid applications. With 10 years of specialized transformer manufacturing experience, we deliver reliable performance that meets global industry standards.

Boasting a precise 33kV high-voltage input and 0.41kV low-voltage output, the toroidal design ensures low energy loss, high efficiency, and stable power transmission. Crafted with H59/H61 high-quality materials, it features excellent corrosion resistance and mechanical strength, paired with advanced oil-immersed insulation for long-term durability in outdoor environments.

Backed by authoritative Type Test Reports, the product guarantees compliance and safety. We also offer flexible OEM services to meet customized project requirements. Ideal for pole-mounted installations in distribution networks, industrial parks, and commercial complexes, this transformer combines professional manufacturing expertise, certified quality, and tailored solutions—your trusted choice for efficient, reliable power distribution.

Product Specification:
Frequency: 50Hz or 60Hz
Capacity: 5kVA ~500kVA
Primary Voltage: 2400~46, 000V
Secondary Voltage: 120~ 600V
Main Technical Datas:
Some of these earthing transformers cover voltage levels including:3.3 kV 5.5 kV  6 kV 6.6 kV 7.2 kV 10kV 10.5kV 11kV 13.2 kV 13.8 kV 15kV 17.5 kV 20 kV  22kV 24kV  30 kV 33kV 34.5kV 35 kV 46 kVetc. and customization is available.

Model NO.

S-m

Core

Core-type Transformer

Cooling Method

Oil-immersed Type Transformer

Winding Type

Two-winding Transformer

Certification

ISO9001-2000, ISO9001, CCC

Usage

Power Transformer

Frequency Characteristics

Power Frequency

Shape of Core

Ring

Brand

Vziman

Color

Gray, Green or Customized

Transport Package

Wooden Packing

Specification

IEC/ANSI/IEEE

Trademark

Vziman

Origin

China

HS Code

8504330000

Production Capacity

20000

 Product Scope:

  • Meet or exceeds ANSI Standards

  • Robust construction having excellent short circuit and thermal withstand capabilities

  • ROCKWELL Transformers are more efficient by Reduced no-load losses and Reduced load losses

  • Customized to Specific Requirements

Three phase pole mounted type distribution transformer Features:

  • Three phase transformer with more economical cost

  • Pole Mounted type transformer for easy installation

  • Oil Filled type for Cooling Method

  • Three phase pole mounted transformer is used for power transmission and distribution, with low loss and high efficiency

  • This type Three phase pole mounted transformer is advanced design to increase short-circuit strength, thermal strength

  • Durable and corrosion resistant finish meets all ANSI/IEC/BS Standards for single phase pole mounted transformer.

  • ROCKWELL Three Phase Pole mout type Automated Deisgn System insures each customer's unique requirements are satisfied.

  • C. R. G. O Silicon Steel or Amorphous Metal is available for customer's option.

Type D16 Series OA Three-Phase Pole-mounted Transformer(CRGO Core BIL 150)

product Photo

Pole Mounted High Voltage Oil Immersed Toroidal Power Transformer

11kV 33kV 35kV 44kV Pole Mounted High Voltage Oil Immersed Toroidal Power Transformer

Pole Mounted High Voltage Oil Immersed Toroidal Power Transformer

 

Durable H61 H59 33kv Power Distribution Transformer for Sale

Wenzhou Rockwell Transformer Co., Ltd. which is specialized in producing, developing and marketing power transmission and distribution products. The company is established in 2008, the subsidiary of ROCKWILL GROUP, which is located in Wenzhou city, Zhejiang province, China.

Our main products are including switchgear, ring main unit, transformer, load break switch, SF6/vacuum circuit breaker, substation, auto-recloser, voltage regulator, automatic sectionalizer, tap-changer, CT and PT etc.

Many of these products have the certification reports of the international authoritative KEMA Netherlands and CESI Italy.

We have a professional technical team which can provide you with full design solution and technical support.

Work shop

H59 H61 Oil Immersed Power Distribution Transformer

Certificates

H59 H61 Oil Immersed Power Distribution Transformer

 

Team

 

H59 H61 Oil Immersed Power Distribution Transformer

Project

H59 H61 13.2kV 13.8kV 15kV 33kV Oil Immersed Power Distribution Transformer Manufacturer

 

Shipping

H59 H61 13.2kV 13.8kV 15kV 33kV Oil Immersed Power Distribution Transformer Manufacturer

Attention

  1. The payment term: We accept TT,30% deposit and 70% balance against copy of BL.

  2. The delivery time: Usually it will take about 15-20 days.

  3. The standard of package: Usually use strong plywood case for protection.

  4. The logo: If you have good quantity, it absolute no problem to do OEM.

  5. Our market: our products are popular in Indonesia, Philippines, Russia, USA, Middle East and so on. Some of them are our regular customers and some of them are developing. We hope you can join us and make mutual benefit from our cooperation..

  6. Warranty: in 12 month since BL date.

Our Service

  1. quick response in before sales period help you got order.

  2. excell ent service in production time let you know each step we made.

  3. reliable quality solve you after sale headache.

  4. long period quality warranty ensure you can buy without hesitate.

Why Choose Vziman

  • One-stop supplier globally.

  • More than 10 years professional experiences in electrical appliance industry.

  • We offer professional online technology support for perfecting your electrical solution free.

  • Experienced sales service and suggestion.

  • All the products with accessories under strict quality control and final inspection before ship

  • We can assure the powerful competitive price and reliable quality products.

  • Most competitive shipping rate from our own shipping forwarder.

  • Warranty assurance: 12 month

  • Whatever big or small order, we can provide you one-to-one service.

Documentation Resource Library
Restricted
Vziman IEC/ ANSI Oil-immersed Power transformer selection catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the specific models of H59 series transformers with different capacities under the 20kV voltage class?
A:

 50KVA capacity (copper winding), suitable for 20kV power grid: H59 50kVA 20KV 400V ±5%
100KVA capacity (copper winding): H59 100KVA 20KV 400V ±5%
160KVA capacity (copper winding): H59 160KVA 20KV 400V ±5%
250KVA capacity:
Aluminum winding version: H59 250KVA 20KV 400V ±5% ALU
Copper winding version: H59 250kVA 20KV 400V ±5%
630kVA capacity:
Aluminum winding under 20kV voltage class: H59 630kVA 20KV 400V ±5% ALU
Copper winding under 20kV voltage class: H59 630kVA 20kV 400V ±5% CU

Q: What are the key maintenance points for the oil-immersed toroidal transformer?
A:
  1. Regularly check the insulation oil level and quality: Ensure the oil level is within the standard range (1/2-2/3 of the oil tank) and replace aged or contaminated oil annually to maintain insulation performance.
  2. Inspect the toroidal core and windings: Conduct a visual check every 6 months for signs of corrosion, loose connections, or overheating (e.g., discoloration), and clean dust with dry air to avoid insulation degradation.
  3. Monitor protective devices: Verify the functionality of pressure relief valves and temperature monitors quarterly to ensure timely alarms for overpressure/overtemperature.
  4. Environmental protection: Keep the transformer installed in a well-ventilated area free from debris accumulation, and protect the H59/H61 metal case from direct impact to extend its service life.
Q: Which application scenarios is this 33/0.41kV toroidal power transformer suitable for?
A:

This H59/H61 33/0.41kV high-voltage oil-immersed toroidal transformer is ideally suited for pole-mounted installation in medium-voltage distribution networks, industrial parks, rural power grids, and commercial complexes. Its toroidal structure ensures compact size and low energy loss, making it perfect for scenarios requiring space-saving installation and stable power supply—such as power distribution for production lines, residential area centralized power supply, and remote area grid extension. It operates reliably in harsh outdoor environments with temperature ranges from -30℃ to 50℃, adapting to humidity, dust, and other adverse conditions.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff:
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    ​1. Challenges in High-Voltage Power Systems​1.1 High-voltage power systems, as the core of power transmission, face critical challenges:​Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements.​Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages.​Poor Environmental Ada
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 ​Grid Frequency Fluctuations and Stability Issues​The intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within m
    05/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.