• GZDW Type DC power supply cabinet
GZDW Type DC power supply cabinet
discuss personally
Model
GZDW-220-48
GZDW-220-110
GZDW-220-220
GZDW-380-220
Basic info
Brand Wone
Model NO. GZDW Type DC power supply cabinet
Rated frequency 50Hz ± 5%
AC input voltage AC380V ± 15%
DC output voltage DC220V
Series GZDW
Product Detail

Description :

I produced GZDW series DC power screen widely used in the power system large,  medium and small power stations and substations and other electrical equipment,  secondary circuit protection devices DC power system, as a control, signaling,  communications, protection and DC emergency lighting, motor starting and power units  and other power equipment can also be used for post and telecommunications and other  industries to meet the needs of power engineering, but also can be used as a DC voltage,  constant current power supply, and other DC operating power. Our company is strong in technology, product performance and stability, has won  the trust of customers, products sold throughout the country and abroad, is the Ministry  of Power Industry sentinel GZDW series DC power supply cabinet (hereinafter referred  to as: DC cabinet) production enterprises. Products in strict accordance with  international and national quality assurance production, product type testing by the  Ministry and experts management system, in line with JB / T 5777.4-2000 "power  system DC power supply General technical conditions and safety requirements" and DL  / T459-2000 "Power system DC power supply cabinet order technical conditions  "requirement. This product uses high-frequency switching power supply module or  phase-controlled rectifier device as charging float charging devices. GZDW with  technical indicators advanced, low maintenance, high efficiency, small size and other  characteristics of the battery charge, floating charge and DC power intelligent  management of working conditions, protection of battery life. Equipped computer  controller (PLC controller or microcontroller) of the product also has a remote function,  improve the reliability and automation level of the DC system.

Technical feature:

  • Efficient power conversion technology.

  • Intelligent management function.

  • Compact structural layout.

  • High-reliability design.

  • Good electromagnetic compatibility.

  • Flexible configuration and expandability.

Main technical parameters:

GZDW Type DC power supply cabinet.png

The use of environmental conditions:

GZDW Type DC power supply cabinet.png

Should you ground a DC power supply?

A:Yes, in many cases, it is necessary to ground a DC power supply. Grounding helps to improve safety by preventing electric shock in case of insulation failure. It also helps to reduce electromagnetic interference and stabilize the electrical potential of the power supply, which is beneficial for the proper operation of electronic devices. However, there are some specific low - voltage and isolated DC power supplies that may not require grounding depending on the application and safety regulations.

image.png

Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Research and Application of Communication Security Strategies for Smart Meters
Research and Application of Communication Security Strategies for Smart Meters
1. Security Threats Facing Smart Meter Communications1.1 Physical Layer Security ThreatsPhysical layer security threats refer to factors that damage or interfere with the hardware devices and physical connections of smart meters, directly affecting their normal operation and data transmission. From the perspective of equipment damage, harsh natural environments such as lightning strikes, floods, and earthquakes can directly destroy the hardware circuits and structures of smart meters, rendering
Echo
09/01/2025
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!