Key attributes

Brand MV Switchgear Accessories
Model NO. GSR8 Solid State Relay with Heatsink 15A-60A
Rated normal current 25A
Rated frequency 50/60Hz
Series GSR8

Product descriptions from the supplier

Description

The GSR8 Series Solid State Relay (SSR) is a high-performance, single-phase AC solid state relay with an integrated heat sink, designed for industrial automation and heating control applications. Utilizing advanced solid-state technology, it features no mechanical contacts, ensuring long lifespan and high reliability. With a compact 22.5mm width, it is easy to install on panels or standard 35mm DIN rails (EN50022). The IP20 protection rating, along with a removable cover, provides enhanced safety. An integrated LED input indicator clearly displays the operational status.

Control Voltage Range:4-32VDC/90-280VAC

Rated Current: 15A, 25A, 40A, 60A

Maxi Turn-On Time(msec):1/2 Cycle

Maxi Turn-Off Time(msec):1/2 Cycle

GSR8 Solid State Relay with Heatsink Product Highlight:

Load Current Options: 15A, 25A, 40A, 60A, meeting various power requirements.

Output Operating Voltage Range: 480VAC or 600VAC.

Trigger Type: Zero-crossing (Z) or Random (R), enhancing system stability.

Integrated Heat Dissipation: Built-in heat sink ensures efficient thermal management, extending service life.

Easy Installation: DIN rail or panel mounting, space-saving design.

Safe and Reliable: Dielectric strength of 2500Vrms, insulation resistance of 10^9Ω, operating temperature range of -30°C to 80°C.

Product Selection

Cortrol Voltage Output
Voltage
  Rated operational current
15Amps  25Amps 40Amps 60Amps
4 to 32VDC 480VAC”Z” GDR8-15DA48Z  GDR8-25DA48Z GDR8-40DA48Z GDR8-60DA48Z
4 to 32VDC 480VAC“R” GDR8-15DA48R  GDR8-25DA48R GDR8-40DA48R GDR8-60DA48R
90 to 280VAC 480VAC”Z” GDR8-15AA48Z  GDR8-25AA48Z GDR8-40AA48Z GDR8-60AA48Z
90 to 280VAC 480VAC”R” GDR8-15AA48R  GDR8-25AA48R GDR8-40AA48R GDR8-60AA48R
4 to 32VDC 600VAC”Z” GDR8-15DA60Z  GDR8-25DA60Z GDR8-40DA60Z GDR8-60DA60Z
4 to 32VDC 600VAC”R” GDR8-15DA60R  GDR8-25DA60R GDR8-40DA60R GDR8-60DA60R
90 to 280VAC 600VAC”Z” GDR8-15AA60Z  GDR8-25AA6OZ GDR8-40AA60Z GDR8-60AA60Z
90 to 280VAC 600VAC”R” GDR8-15AA60R  GDR8-25AA60R GDR8-40AA6OR GDR8-60AA60R

Input Specifications

Description Specification Limits
Control Voltage Range 4-32VDC 90-280VAC
Maximum Reverse Voltage -6VDC /
Minimum Turn-On Voltage 4VDC 90VAC
Must Turn-Off Voltage 1V 10VAC
Minimum Input Current [for on-state] 10mA 6.5mA
Maximum Input Current [mA] 20mA 18mA
Maximum Turn-On Time [msec] 1/2 Cycle 1/2 Cycle
Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle

Output Specifications

Description Units Specification Limits
Model No.GSR  Amp 15 25 40 60
Load Current Range Arms 0.05-15 0.05-25 0.05-40 0.1-60
Surge Current 10mSec[Max.] Arms 150 250 400 600
Load Voltage Range [480V] Vrms 24-480
Transient Overvoltage [480V]  Vpk 800
Load Voltage Range [600V] Vrms 24-600
Transient Overvoltage [600V]  Vpk 1200
Operating Frequency Range Hz 47~63
Off State dv/dt [min.] V/μs 200 200 200 500
Off State Leakage Current [Max.] mA ≤8
On State Voltage Drop [Max.] Vrms 1.5 1.5 1.5 1.6
Turn On Time [Max.]”Zero-crossing” Cycle 1/2
Turn On Time [Max.]”Random-on” mSec 1
Turn-off Time [DC input] Cycle 1/2
Turn-off Time [AC input] mSec 10

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.