Brand MV Switchgear Accessories
Model NO. GSR-3 Three Phase Solid State Relay
Output current 10A
Series GSR

Product descriptions from the supplier

Description

The GSR1-3 AA three-phase solid state relay (SSR) is a high-performance contactless switching device developed based on modern microelectronics and power electronics technology. It is designed specifically for intelligent control of three-phase AC loads, using weak control signals (such as TTL, DTL, HTL logic levels) to safely drive high current loads and achieve electrical isolation between input and output circuits.

Applications:

AC DC switch & Temp control

Automate Control

CNC machinery

Packaging machinery

Textile machinery

Glass machinery

Plastic machinery

Wide input voltage range and small control current, less than or equal to 20mA;

No mechanical action parts, long service life, and high reliability;

Fast switching speed, zero voltage on, zero current off, low RF interference;

Built in resistance-capacitance absorption to protect the impact of the product on the starting instant current;

Photoelectric isolation between input and output circuits, insulation and withstand voltage of 2500V;

The product is small in size and filled with epoxy resin, which is shockproof, moisture-proof and corrosion-proof

input parameter                
Control voltage range 70-280VDC
Ensure shutdown voltage 50VAC
Ensure that the voltage is turned on 90VAC
General characteristics                
Installation mode Bolt fixing
Insulation and withstand voltage between input and output 2500Vrms
Insulation and withstand voltage between input and output and housing 4000Vrms
Leakage current under off state ≤8mArms ≤2mArms
Maximum control current 10mA
Minimum control current 5mA
On-off reaction delay ≤10ms
Output parameters                
Output voltage range 24-480VAC
Peak voltage 800VAC 1200VAC
Relevant certification CE
Saturation pressure drop in on state ≤1.5V
Specification / maximum load current 10A 25A 40A 60A 80A 100A 120A 200A
ambient temperature -20°~75°C
insulation resistance 1000MΩ/500VDC
size 105L×74W×33H
weight 500g

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.