GRV8-SV Voltage Sensing Relay

  • GRV8-SV Voltage Sensing Relay
  • GRV8-SV Voltage Sensing Relay

Key attributes

Brand MV Switchgear Accessories
Model NO. GRV8-SV Voltage Sensing Relay
Rated frequency 45Hz-65Hz
Series GRV8

Product descriptions from the supplier

Description

The GRV8-SV Voltage Sensing Relay monitors voltage levels. It acts when voltage is too high or too low. This protects your equipment from damage and prevents costly downtime. It’s designed for industry, agriculture, and transportation. Its DIN rail mounting is simple. It takes up little space. An intuitive LCD shows voltage data. It measures voltage accurately with true RMS. You can count on its accuracy and reliability.

Product Highlight:

Dual Voltage Protection: Safeguards against over-voltage and under-voltage, keeping your equipment within safe operating limits.

True RMS Measurement: Provides accurate voltage readings with ±1% precision for dependable monitoring.

Normal/Emergency Power Switching: Seamlessly transitions between power supplies, ensuring uninterrupted operation.

Real-Time LCD Display: Offers clear, instant visibility of voltage levels and system status.

Compact Design: 2-module width with DIN rail mounting for easy integration into control panels.

Product Description:

The GRV8-SV voltage sensing relay, with its dual voltage protection, True RMS high-precision measurement, real-time LCD display, compact design, wide applicability, high durability, certified quality, and user-friendly features, is the ideal choice for protecting equipment from voltage fluctuations and ensuring stable system operation.

Model GRV8-SV
   
Function Over voltage, under voltage
Rated supply voltage AC/DC110V…240V
Rated supply frequency 45~65Hz,0Hz
Operation voltage range 50V~350V
Burden AC max.3VA
Over voltage operation value 65V~300V,OFF
Under voltage operation value OFF,65V~300V
Over/under voltage action delay 0.1s~20s
Power-up delay 0.5s~300s
Reset time 0.5s~300s
Measurement error ≤1%
Output 2×SPDT
Current rating 8A/AC1
Switching voltage 250VAC/24VDC
Electrical life(AC1) 1×107
Mechanical life 1×105
Operating temperature -20℃ ~ +60℃
Storage temperature -35℃ ~ +75℃
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage cathegory III
Pollution degree 2
Max.cable size(mm²) solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
Tightening torque 0.4Nm
Dimensions 82*36* 68mm
Weight 100g
Standards EN 60255-1,IEC60947-5-1

Parameter setting

Parameter Range Step value Factory settings
Over voltage value 65V~300V,OFF 1V 253V
Over voltage recovery value 60V~295V 1V 248V
Under voltage value OFF,65V~300V 1V 187V
Under voltage recovery value 70V~305V 1V 192V
Voltage fault action time 0.1s~20s 0.1s 2s
Power on delay time 0.5s~300s 0.1s/1s 0.5s
Reset time 0.5s~300s 0.1s/1s 1s
Fault reset ON-OFF / ON
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.