Key attributes

Brand Switchgear parts
Model NO. GPS8-13 Low Voltage Protector
Rated voltage AC220V
Rated normal current 40A
Rated frequency 45Hz-65Hz
Series GPS8-13

Product descriptions from the supplier

Description

The GPS8-13 voltage/current protector is an intelligent protection device designed specifically for household electrical safety, integrating high-precision monitoring, multiple protections, and user-friendly functions. Through the true effective value (RMS) measurement technology and intelligent control, this product can monitor the voltage and current status in the circuit in real time, and quickly cut off the power supply in abnormal situations such as overvoltage, undervoltage, or overcurrent, effectively avoiding damage to electrical equipment caused by power fluctuations and providing security for household electricity safety.

GPS8-13 Voltage/Current Protector Product Features:
1. True effective value monitoring technology
By using True RMS measurement technology, the dynamic changes of voltage and current can be accurately captured, ensuring the accuracy of data measurement and the reliability of protective actions even in complex working conditions such as nonlinear loads or waveform distortion.
2. Dual contact power-off design
Support synchronous disconnection of live wire (L) and neutral wire (N) dual contacts, completely cutting off circuit faults and avoiding potential risks caused by single wire disconnection, with higher safety.
3. Multiple parameter customization settings
Users can flexibly set overvoltage, undervoltage, and overcurrent thresholds according to their actual needs, adapt to the protection requirements of different household appliances, and provide personalized protection solutions.
4. Double busbar wiring structure
Adopting a dual busbar connection design to enhance current carrying capacity and stability, it is suitable for high load household electricity scenarios and operates stably and reliably for a long time.
5. Intelligent self reset function
Automatically restore power supply after troubleshooting, reducing manual intervention, improving convenience of use, and avoiding inconvenience caused by frequent manual resets.
6. Visual status display
Equipped with a digital display screen and multi-color LED indicator lights, it displays real-time voltage, current values, and equipment operating status, making fault types clear at a glance and facilitating quick troubleshooting.
7. Compact modular design
Standard 1 module size, supports DIN rail installation, saves distribution box space, easily adapts to existing home circuit systems, easy installation and simple maintenance.

Model

GPS8-13 Low Voltage Protector

Function

Over voltage, under voltage and over current

Rated supply voltage

AC220V(L-N)

Rated supply frequency

45~65HZ

Operation voltage range

80V~400V(L-N)

Rated operational current

63A,80A(AC1)

Burden

AC max.3VA

Over voltage operation value

OFF,230V~300V

Under voltage operation value

140V~210V,OFF

Over/under voltage action delay

0.1s~10s

Over current operation value

1~63A,80A

Over current action delay

2s~600s

Power-up delay

2s~600s

Reset time

2s~900s

Measurement error

≤1%

Electrical life(AC1)

1*104

Mechanical life

1*106

Operating temperature

-20℃ ~ +60℃

Storage temperature

-35℃ ~ +75℃

Mounting/DIN rail

Din rail EN/IEC 60715

Protection degree

IP40 for front panel/IP20 terminals

Operating position

any

Overvoltage category

Pollution degree

2

Dimensions

82x54x68mm

weight

135g

Documentation Resource Library
Restricted
GPS8-13 Low Voltage Protector
Operation manual
English
Consulting
Consulting
FAQ
Q: What are the core functions and advantages of the GPS8-13?
A:

The core functions and advantages focus on four dimensions: comprehensive protection, precise measurement, installation adaptability and reliable use:

· Three-in-one precise protection: Integrates overvoltage, undervoltage and overcurrent protection with customizable protection thresholds. The dual-contact disconnection design ensures complete cutoff of the fault circuit, avoiding equipment burnout or electric shock risks.

· High-precision monitoring and display: Equipped with True RMS measurement technology, the voltage and current measurement error is ≤1%. The digital display synchronously shows dual parameters in real time, and LED indicators quickly locate fault types (overvoltage/undervoltage/overcurrent).

· Convenient installation and adaptation: 35mm standard DIN rail plug-and-play, compact size (refer to the same series 82×36×68mm) and light weight, allowing dense arrangement with circuit breakers and relays, saving power distribution space.

· High reliability and humanized design: Dual-bus wiring design improves power supply stability; the operating temperature ranges from -20℃ to +60℃, with a protection level of IP40 (front panel)/IP20 (terminals); automatic reset after fault eliminates the need for manual intervention, reducing operation and maintenance costs.

Q: What is the GPS8-13 Low Voltage Protector?
A:

The GPS8-13 is a multi-functional intelligent protection device specially designed for low-voltage power distribution systems, integrating three-in-one protection of overvoltage, undervoltage and overcurrent. Compatible with AC 220V rated voltage and 45~65Hz frequency, it covers a working voltage range of 80V~400V. Adopting 1-MODULE standard DIN rail installation, it is equipped with True RMS measurement technology with a measurement accuracy ≤1%, supporting digital display of dual parameters (voltage and current) and LED fault indicators. Featuring dual-bus wiring design and dual-contact disconnection function, it automatically resets (adjustable reset time) after fault elimination. Widely used in residential power distribution, small commercial premises and old circuit renovation, it fully protects electrical equipment and electrical safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.