• Energy Efficient Medium Voltage Transformers
Energy Efficient Medium Voltage Transformers
discuss personally
Model
Liquid-Filled /Power Dry-three
Liquid-Filled /Power Dry-single
Basic info
Brand Schneider
Model NO. Energy Efficient Medium Voltage Transformers
Phases Single-phase
Series Liquid-Filled /Power Dry
Product Detail

General

Features and Benefits

  • Improved energy efficiency
    Decreased operating costs equal increased profits

  • Less heat generated
    Lower A/C and ventilation costs/requirements if located indoors

  • Lower total ownership costs over the life of the transformer

Environmental Impact

According to the DOE (10 CFR Part 431), these new standards provide significant benefits to the nation. Saves 2.74 quads (1,015 BTUs) of energy over 29 years

  •  Equivalent to energy used in 27 million U.S. households in a single year  Eliminates the need for six new 400 MW power plants

  • Reduces greenhouse gas emission by approximately 238 million tons of CO2 Equivalent to removing 80% of all light vehicles for one year

 

Technical characteristics

New Medium Voltage Transformer Efficiencies

Single phase

Three phase 

Medium Voltage Transformers

 

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
10 years
Workplace
20000m²
占位
占位
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul