Key attributes

Brand ROCKWILL
Model NO. DS5 40.5kV 72.5kV 126kV High voltage disconnect switch
Rated voltage 72.5kV
Rated normal current 2000A
Series DS5

Product descriptions from the supplier

Description

Description:

DS5 series disconnector adopts double-column horizontal V-type rotation structure, which is composed of three unipolar and operating mechanism. Each single electrode consists of a base, a post insulator, and a conducting part. A rotating pillar insulator is installed at both ends of the base, and the contact arm and contact arm of the main electrical part are respectively fixed on the top of the pillar insulator.

The operating mechanism drives one end of the pillar insulator to rotate, and drives the other end of the pillar insulator to reverse rotate 90° through the cross connecting rod, so that the conductive knife can turn on the horizontal plane to realize the isolation switch opening and closing. The opening state forms a horizontal insulation fracture.

 

Main Features:

 

  •  The conductive arm is made of rectangular aluminum alloy tube or aluminum alloy plate, high strength, light weight, large heat dissipation area, good anti-corrosion performance;

  • The contact part of the conductive arm adopts external pressure plate spring structure. The plate spring is made of alloy material with good elasticity, which can keep the contact pressure stable for a long time and overcome the drawbacks of the spring internal pull structure.

Technical parameter:

 

 

What are the main functions of the disconnector?

 

This is the primary function of an isolator switch. When performing maintenance or inspection on electrical equipment, the isolator switch is opened to create a clear break point between the equipment and the power supply. The insulation distance at this break point must meet relevant standards to ensure that no voltage from the power side is applied to the equipment side, thus ensuring the safety of the operators and the equipment. For example, when inspecting a transformer in a substation, the isolator switch connected to the transformer is first opened to isolate the transformer from the grid, before proceeding with subsequent maintenance work.

Auxiliary Function in Switching Operations:

In switching operations in substations and other electrical systems, isolator switches are used in conjunction with circuit breakers and other switching devices. Although isolator switches cannot interrupt normal load currents or short-circuit currents, they can be used to change the connection configuration of the circuit after the circuit breaker has already interrupted the circuit. For instance, they can be used to switch a line from one busbar to another. However, these operations must be performed strictly according to the operating procedures, as incorrect operation sequences can lead to serious electrical accidents.

Opening and Closing Small Current Circuits;

Isolator switches can be used to open and close small current circuits, such as the no-load currents of voltage transformers and surge arresters, and capacitive currents. However, they cannot be used to open and close normal load currents or short-circuit currents because they lack arc-quenching devices (or have very weak arc-quenching capabilities). Attempting to open or close large currents can result in intense arcs, damaging the isolator switch and potentially causing electrical fires or other accidents.

Documentation Resource Library
Restricted
12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
Consulting
Consulting
FAQ for
Q: Which manufacturer's products should be prioritized for frequently operated wind farm step-up substations?
A:

Considering the requirements for equipment reliability and frequent operation in wind farm step-up substations, the following models are recommended:

  • Rockwill Electric: DS4C-252/4000, with voltage and current parameters highly compatible for outdoor applications in wind power scenarios, providing isolation functions to ensure operational safety.

  • Siyuan Electric: GW5-G-252D/2000, an improved design that enhances contact wear resistance and overall reliability.

  • Changgao Electric: GW5C-252DD/3150, specifically designed for renewable energy projects, featuring rapid response and high reliability.

  • Shandong Taikai: GW5-126D/2000, while with a lower voltage rating, is a suitable option for wind farm step-up substations at 126kV and below.

Comparison Points:

  • Operational Lifespan: The "G" improved version from Siyuan and the "C" optimized version from Changgao emphasize product durability, making them suitable for frequent operation scenarios.

  • Cost-Effectiveness: Products from Rockwill and Taikai are renowned for their cost-performance advantages, making them ideal choices when budget constraints are a concern.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Installation Requirements and Procedures for 10 kV High-Voltage Disconnect Switches
    First, the installation of 10 kV high-voltage disconnect switches must meet the following requirements. The first step is to select an appropriate installation location, typically near the switchgear power supply in the power system to facilitate operation and maintenance. At the same time, sufficient space must be ensured at the installation site to accommodate equipment placement and wiring.Secondly, equipment safety must be fully considered—for example, lightning protection and explosion-proo
    11/20/2025
  • Common Issues and Handling Measures for 145kV Disconnector Control Circuits
    The 145 kV disconnector is a critical switching device in substation electrical systems. It is used in conjunction with high-voltage circuit breakers and plays an important role in power grid operation:First, it isolates the power source, separating equipment under maintenance from the power system to ensure personnel and equipment safety;Second, it enables switching operations to change the system operating mode;Third, it is used to interrupt small-current circuits and bypass (loop) currents.Re
    11/20/2025
  • What are the six operating principles of disconnect switches?
    1. Operating Principle of the DisconnectorThe operating mechanism of the disconnector is connected to the active pole of the disconnector via a connecting tube. When the main shaft of the mechanism rotates 90°, it drives the insulating pillar of the active pole to rotate 90°. The bevel gears inside the base drive the insulating pillar on the other side to rotate in the opposite direction, thereby achieving opening and closing operations. The active pole, through inter-pole linkage tubes, drives
    11/19/2025
  • 36kV Disconnect Switch Selection Guide & Key Parameters
    Selection Guidelines for 36 kV Disconnect SwitchesWhen selecting the rated voltage, ensure that the disconnect switch’s rated voltage is equal to or higher than the nominal voltage of the power system at the installation point. For example, in a typical 36 kV power network, the disconnect switch must have a rated voltage of at least 36 kV.For rated current, selection should be based on the actual long-term load current. Generally, the switch’s rated current must be no less than the maximum conti
    11/19/2025
  • Copper Conductor Size vs Temperature Rise in 145kV Disconnectors
    The relationship between the temperature-rise current of a 145 kV disconnector and copper conductor size lies in balancing current-carrying capacity and heat dissipation efficiency. The temperature-rise current refers to the maximum continuous current a conductor can carry without exceeding its specified temperature rise limit, and the copper conductor size directly influences this parameter.Understanding this relationship begins with the physical properties of the conductor material. Copper’s c
    11/19/2025
  • Design of an Intelligent Control System for Fully Enclosed Disconnectors in Distribution Lines
    Intelligentization has become an important development direction for power systems. As a critical component of the power system, the stability and safety of 10 kV distribution network lines are vital to the overall operation of the power grid. The fully enclosed disconnector, as one of the key devices in distribution networks, plays a significant role; thus, achieving its intelligent control and optimized design is of great importance for enhancing the performance of distribution lines.This pape
    11/17/2025

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.