• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


DS5 40.5kV 72.5kV 126kV disiunctor de alta tensio

  • DS5 40.5kV 72.5kV 126kV High voltage disconnect switch

Attributa principalia

Marca ROCKWILL
Numerus Modeli DS5 40.5kV 72.5kV 126kV disiunctor de alta tensio
Votum nominatum 126kV
currus electricus nominatus 2000A
Series DS5

Descriptiones productorum a fornitori

Descriptio

Descriptio:

Series DS5 disiunctores adoptant structuram rotationis V horizontalis bini columnae, quae constat ex tribus unipolaribus et mechanismo operationis. Unumquodque singulum electrum constat ex basi, insulator postico, et parte conductiva. Insulator pillar rotator est installatus in utroque latere basis, et bracchium contactus et bracchium contactus partis electricae principali sunt respecte fixa in summo insulatoris pillar.

Mechanismus operationis movet unum latere insulatoris pillar ad rotandum, et movet alterum latere insulatoris pillar ad rotandum inversum 90° per rodum transversalem, ut possit culter conductor verti in plano horizontali ad realisandum aperturam et clausuram disiunctoris. Status apertus format fracturam insulationis horizontalis.

 

Characteristica Principalia:

 

  •  Bracchium conductor est factum ex tubo aluminii alliage rectangulare vel lamina aluminii alliage, fortitudine magna, pondere levi, area dissipationis caloris magna, performance anti-corrosionis bona;

  • Pars contactus brachii conductoris adoptat structuram mallei externi pressurae. Malleus est factus ex materia alliage cum elasticitate bona, qui potest manere pressura contactus stabilis per longum tempus et superare defectus structurae tractionis internae mallei.

Parametri technici:

 

 

Quae sunt functiones principales disiunctoris?

 

Hoc est functio principalis commutatoris isolationis. Cum operatio maintenance vel inspectionis fieri debeat super apparatu electrico, disiunctor aperitur ad creandum punctum rupturem clarum inter apparatum et supplymentum electricum. Distantia insulationis in hoc puncto ruptura debet satisfacere standardibus pertinentibus ad securitatem operantium et apparatorum. Exempli gratia, quando inspectio transformatoris in substatione fit, disiunctor connectus ad transformatorum primum aperitur ad isolandum transformatorum ab rete, ante procedendum ad subsequentem opus maintenance.

Functio Auxiliaris in Operationibus Commutationis:

In operationibus commutationis in substationibus et aliis systematis electricis, disiunctores utuntur in conjunctione cum circuitobrakeis et aliis dispositivis commutationis. Licet disiunctores non possint interruptu currentus normalis oneris vel currentus short-circuit, possunt uti ad mutandum configurationem connectionis circuitus postquam circuitobrakeus iam interruptit circuitum. Exempli gratia, possunt uti ad commutandum lineam ab uno busbar ad alterum. Tamen, haec operationes debent fieri stricto secundum procedure operationis, quia sequentia operationum incorrecta possunt ducere ad accidentia electrica seria.

Aperiens et Claudiens Circuitus Parvorum Currentium;

Disiunctores possunt uti ad aperiendum et claudendum circuitus parvorum currentium, sicut currentus sine onere transformatorum tensionis et surge arrestor, et currentus capacitive. Tamen, non possunt uti ad aperiendum et claudendum currentus normalis oneris vel currentus short-circuit quia carent dispositivis arc-quenching (vel habent vires arc-quenching valde tenuis). Conati aperiendi vel claudendi magnos currentus possunt resultare in arcus intensos, damnum adferentes disiunctorem et potentiando incendia electrica vel alia accidentia.


 

Bibliotheca Documentorum Rerum
Restricted
12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
Consulting
Consulting
FAQ
Q: Cuius manufactorae producta prioriter in stationibus substationum elevativarum saepe operatarum ventorum debent considerari
A:

Considerando requisitiones pro fide dignitatis instrumentorum et frequenti operatione in substationibus adiutoriis agrorum ventorum, sequentes formae commendantur:

  • Rockwill Electric: DS4C-252/4000, cum parametris voltus et currentis valde compatibilibus pro usibus externis in scenariis venti, praebens functiones isolationis ut operativam securitatem confirmet.

  • Siyuan Electric: GW5-G-252D/2000, designo meliorato quod resistibilitatem usurae contactuum et fidem generalem augeat.

  • Changgao Electric: GW5C-252DD/3150, specialiter designata pro projectis energiarum renovabilium, praebens celerem responsionem et fidem altam.

  • Shandong Taikai: GW5-126D/2000, quamvis cum rating inferior voltus, est optio idonea pro substationibus adiutoriis agrorum ventorum ad 126kV et infra.

Puncta Comparationis:

  • Vita Operativa: Versio "G" meliorata ab Siyuan et versio "C" optimizata ab Changgao accentuatur durabilitatem producti, faciens eos aptos pro scenariis operationis frequentis.

  • Cost-effective: Producta ab Rockwill et Taikai sunt notabilia pro suis avantaggiis cost-performance, facienda eas electiones ideales quando limitationes budgetariae sunt de consideratione.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum