• DS1 12kV 40.5kV 72.5kV High voltage disconnect switch
DS1 12kV 40.5kV 72.5kV High voltage disconnect switch
discuss personally
Model
DS1-72.5D/2500-40
DS1-72.5D/2000-31.5
DS1-72.5D/1250-31.5
DS1-72.5D/630-31.5
DS1-40.5D/2500-40
DS1-40.5D/2000-31.5
DS1-40.5D/1250-31.5
DS1-40.5D/630-31.5
DS1-12D/2500-40
DS1-12D/2500-31.5
DS1-12D/2000-31.5
DS1-12D/1250-31.5
DS1-12D/630-31.5
Basic info
Brand ROCKWILL
Model NO. DS1 12kV 40.5kV 72.5kV High voltage disconnect switch
Rated voltage 40.5kV
Rated normal current 2500A
Rated frequency 50/60Hz
Rated peak value withstand current 100kA
Rated short-time withstand current 40kA
Series DS1
Product Detail

Product introduction:

DS1-12、40.5、72.5 switch disconnectors  are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and break.

GW1  switch disconnector have two insulators with vertical open jewels. Vertical breaks Will be formed after closing, phase spacing can be educed. Its structure is simple, and it is a Widely used structure in early switch disconnector 

Product is made of conductive am, post insulator, operating insulator, and base. Conductive arm is derived by operation and connecting rod about 50 •tums up and down, complete the opening and closing operation. According the need, we can match manual or electric mechanism.

Main characteristic:

  • The conductive arm, made of Cu-alloy of high conductance rate is characteristic of high mechanical strength, large radiation area.
  • Self-energy contact finger-Pressure and stable, self-energy contact finger is characterized by high elasticity, high conductivity, high temperature resistant, corrosion resistant properties. The end of the contact finger is fixed, it can avoid increasing contact resistance. Tile contact finger has been acknowledged by the China National Utility Model Patent. The structure has been us的 more than ten years, more than 100000 sets, without overheating feedback.
  • Tile dynamic contact part adopts the self-cleaning structure. Tile products cleaning the contact surface during close and open operation itself, which reduce the contact resistance and avoid healing of contact surface.
  • The rotating parts of Switch disconnector are designed to be free maintenance. Imported self-lubricating shaft sleeve, high quality stainless steel shaft pin, long-lasting aviation grease are used for forever flexile rotation and no clamping stagnation
  • All Switch disconnectors are delivered after complete assembly and adjustment. The product is convention to install, significantly reducing installation work on site.
  • Provide one-key sequential control "double confirmation" function expansion

Main technical parameters:

Order notice :

Product model, rated voltage, rated current, creepage distance must be specified at the goods-ordering time;

The disconnect switch offers several options of grounding;

The operating mechanism, motor voltage, control voltage and the number of contacts for auxiliary switch;

Installation method.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!