• DS1 12kV 40.5kV 72.5kV High voltage disconnect switch
DS1 12kV 40.5kV 72.5kV High voltage disconnect switch
discuss personally
Model
DS1-72.5D/2500-40
DS1-72.5D/2000-31.5
DS1-72.5D/1250-31.5
DS1-72.5D/630-31.5
DS1-40.5D/2500-40
DS1-40.5D/2000-31.5
DS1-40.5D/1250-31.5
DS1-40.5D/630-31.5
DS1-12D/2500-40
DS1-12D/2500-31.5
DS1-12D/2000-31.5
DS1-12D/1250-31.5
DS1-12D/630-31.5
Basic info
Brand ROCKWILL
Model NO. DS1 12kV 40.5kV 72.5kV High voltage disconnect switch
Rated voltage 12kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 80kA
Rated short-time withstand current 31.5kA
Series DS1
Product Detail

Product introduction:

DS1-12、40.5、72.5 switch disconnectors  are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and break.

GW1  switch disconnector have two insulators with vertical open jewels. Vertical breaks Will be formed after closing, phase spacing can be educed. Its structure is simple, and it is a Widely used structure in early switch disconnector 

Product is made of conductive am, post insulator, operating insulator, and base. Conductive arm is derived by operation and connecting rod about 50 •tums up and down, complete the opening and closing operation. According the need, we can match manual or electric mechanism.

Main characteristic:

  • The conductive arm, made of Cu-alloy of high conductance rate is characteristic of high mechanical strength, large radiation area.
  • Self-energy contact finger-Pressure and stable, self-energy contact finger is characterized by high elasticity, high conductivity, high temperature resistant, corrosion resistant properties. The end of the contact finger is fixed, it can avoid increasing contact resistance. Tile contact finger has been acknowledged by the China National Utility Model Patent. The structure has been us的 more than ten years, more than 100000 sets, without overheating feedback.
  • Tile dynamic contact part adopts the self-cleaning structure. Tile products cleaning the contact surface during close and open operation itself, which reduce the contact resistance and avoid healing of contact surface.
  • The rotating parts of Switch disconnector are designed to be free maintenance. Imported self-lubricating shaft sleeve, high quality stainless steel shaft pin, long-lasting aviation grease are used for forever flexile rotation and no clamping stagnation
  • All Switch disconnectors are delivered after complete assembly and adjustment. The product is convention to install, significantly reducing installation work on site.
  • Provide one-key sequential control "double confirmation" function expansion

Main technical parameters:

Order notice :

Product model, rated voltage, rated current, creepage distance must be specified at the goods-ordering time;

The disconnect switch offers several options of grounding;

The operating mechanism, motor voltage, control voltage and the number of contacts for auxiliary switch;

Installation method.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!