Customization 15kV 30kV 33kV 34.5kV 36kV Three Phase Neutral Grounding/earthing Transformer direct supply

  • Customization 15kV 30kV 33kV 34.5kV 36kV Three Phase Neutral Grounding/earthing Transformer direct supply

Key attributes

Brand ROCKWILL
Model NO. Customization 15kV 30kV 33kV 34.5kV 36kV Three Phase Neutral Grounding/earthing Transformer direct supply
Rated voltage 36kV
Rated normal current 3000A
Rated frequency 50/60Hz
Series JDS

Product descriptions from the supplier

Description

Description

As a pioneer and the first dedicated original equipment manufacturer (OEM) in China's earthing transformer industry, we have laid the original benchmark for the industry's development with our profound technical strength accumulated through decades of intensive cultivation. From the independent R&D of core technologies to large-scale mass production, we have built a full-process independently controllable system. Relying on stable and leading product performance and unparalleled reliability, we have become a preferred partner in the field of power grid construction.

This grounding transformer, suitable for systems up to 36kV, is a specialized electrical device. It creates an artificial neutral point in power grids, playing a crucial role in grounding protection. By effectively handling single - phase ground faults, it ensures the stable operation of medium - voltage power systems, whether in urban distribution networks or industrial power setups.

Feature

  • Voltage Adaptability:Designed for up to 36kV systems, it matches the common voltage levels of medium - voltage power grids, ensuring wide - ranging applicability.

  • Fault Handling:Efficiently suppresses arc - grounding overvoltages during single - phase ground faults. It helps reduce ground fault currents, minimizing damage to power grid equipment and enhancing system reliability.

  • Robust Construction:Built with high - quality materials like premium magnetic cores and durable windings. The enclosure is sturdy, resisting harsh environmental factors such as moisture and dust, ensuring long - term stable performance.

  • Safety Enhancement:Provides a reliable neutral grounding solution, preventing abnormal voltage fluctuations and equipment insulation damage, thus safeguarding the safety of the entire power grid and connected electrical devices.

Main technical parameter

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Types

 oil-immersed [ZN(Zig-zag), ZNyn]

Voltage

Up to 36kV

Current

Up to 3000A

Duty (seconds)

10 / 30 / 60 or others

Cooling method

ONAN, ONAF; AN, AF

Frequency

50 / 60Hz

Installation

Indoor / Outdoor

Ambient Temperature

-25°C to 40°C

Standards

IEC 60076-6

IEC 60076-1

Enclosure Options

Transformer cabinets for any IP degreess with:

-CT

-VT

-Isolation switch

Note: This parameter table is for reference. We can offer customize production tailored to client specifications.

Scope of Application

Suitable for scenarios with varying capacities and voltage levels.

  • 35kV and Above Distribution Networks: Transformer windings typically adopt a star (Y) connection with an accessible neutral point, eliminating the need for grounding transformers.

  • 6kV and 10kV Distribution Networks: Transformer windings mostly use delta (Δ) connections without accessible neutral points, requiring grounding transformers to provide a neutral point.

Special Scenarios: When system unbalanced voltage is high, Z-type transformers can meet measurement requirements through balanced design of their three-phase windings. When system unbalanced voltage is low (e.g., fully cable-based networks), the neutral point of Z-type transformers must generate an unbalanced voltage of 30-70V to satisfy measurement criteria.

Purpose and Function: Provides a return path for fault currents, ensuring safety and stability during ground faults.

Operating Principle During Faults: During a ground fault, fault current flows through the transformer’s neutral point. The counteracting magnetic flux generated by reverse current neutralizes impedance.

Voltage and Current Ratings: Rated voltage matches the system’s line voltage. Capable of withstanding maximum fault currents for up to 30 seconds.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.