  • CKSS-12 Electrical ring main unit switchgear

Key attributes

Brand ROCKWILL
Model NO. CKSS-12 Electrical ring main unit switchgear
Rated voltage 12kV
Rated frequency 50/60Hz
Series CKSS

Product descriptions from the supplier

Description
Description

As industrial enterprises and institutions build new buildings, from the perspective of power supply and distribution, distribution transformers are generally small and medium-sized, with a capacity of no more than 1250kva, long-term reliable power supply and infrequent operation of high-voltage switches. For this kind of users, the functions of ring network cabinet are not the most complete, but they can best meet the requirements of ring network. Due to large-scale urban construction, many large-scale high-rise buildings have sprung up, and substations are often located downstairs. According to the fire protection requirements, substations and distribution equipment must be "oil-free", and with regard to the rational use of building area, transformers and distribution equipment. Due to the need for further miniaturization of equipment, annular bodies, vacuum circuit breakers, dry-type transformers and dry-type transformers are suitable for high-rise buildings under construction. The ring network cabinet has the advantages of simple structure, stable and safe operation, low maintenance cost and low operation cost. Compared with the switchgear with circuit breaker, it has outstanding advantages. The ring main cabinet needs higher function and smaller size load switch.

Product features

Cabinet structure: the inflatable compartment is made of 3 ~ 5mm thick stainless steel plate, which is welded by welding robot after being processed by NC machine tool, with less welding deformation and good air tightness. The other compartments are made of high-quality cold-rolled steel plate, which is welded after NC bending, with the characteristics of high precision and good strength; Each functional unit is an independent module, which is very convenient for assembly. Each sealed compartment of the cabinet is equipped with an independent pressure relief channel to ensure personal safety and equipment operation to the greatest extent. b. Protection grade: IP67 for inflation isolation; Low voltage cabinet is IP4X.

Normal service conditions

  • Ambient air temperature: maximum 40 ℃, (average value within 24 hours shall not exceed 35 ℃), minimum - 25 ℃

  • Altitude: no more than 3000m (coordinate with the manufacturer when it exceeds 3000m)

  • Air humidity: the average value of daily relative humidity shall not be greater than 95%, and the average value of monthly relative humidity shall not be greater than 90%

  • The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kV

Technical parameter

Rated voltage

kV

12

Power frequency withstand voltage

phase to phase/earth

kV

42

Power frequency withstand voltage

Between open contacts

kV

48

Impulse withstand voltage phase to phase/earth

kV

75

Impulse withstand voltage

Between open contacts

kV

85

Rated frequency

Hz

50

Rated current

A

630

Rated short-time withstand current (4s)

kA

20/25

Rated peak withstand current

kA

50/63

Rated active load breaking current

A

630

Rated closed loop breaking current

A

630

Mechanical lifetime

Ops

10000

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.