• CKSS-12 Electrical ring main unit switchgear
CKSS-12 Electrical ring main unit switchgear
discuss personally
Model
CKSS-12
Basic info
Brand ROCKWILL
Model NO. CKSS-12 Electrical ring main unit switchgear
Rated voltage 12kV
Rated frequency 50/60Hz
Series CKSS
Product Detail
Description

As industrial enterprises and institutions build new buildings, from the perspective of power supply and distribution, distribution transformers are generally small and medium-sized, with a capacity of no more than 1250kva, long-term reliable power supply and infrequent operation of high-voltage switches. For this kind of users, the functions of ring network cabinet are not the most complete, but they can best meet the requirements of ring network. Due to large-scale urban construction, many large-scale high-rise buildings have sprung up, and substations are often located downstairs. According to the fire protection requirements, substations and distribution equipment must be "oil-free", and with regard to the rational use of building area, transformers and distribution equipment. Due to the need for further miniaturization of equipment, annular bodies, vacuum circuit breakers, dry-type transformers and dry-type transformers are suitable for high-rise buildings under construction. The ring network cabinet has the advantages of simple structure, stable and safe operation, low maintenance cost and low operation cost. Compared with the switchgear with circuit breaker, it has outstanding advantages. The ring main cabinet needs higher function and smaller size load switch.

Product features

Cabinet structure: the inflatable compartment is made of 3 ~ 5mm thick stainless steel plate, which is welded by welding robot after being processed by NC machine tool, with less welding deformation and good air tightness. The other compartments are made of high-quality cold-rolled steel plate, which is welded after NC bending, with the characteristics of high precision and good strength; Each functional unit is an independent module, which is very convenient for assembly. Each sealed compartment of the cabinet is equipped with an independent pressure relief channel to ensure personal safety and equipment operation to the greatest extent. b. Protection grade: IP67 for inflation isolation; Low voltage cabinet is IP4X.

Normal service conditions

  • Ambient air temperature: maximum 40 ℃, (average value within 24 hours shall not exceed 35 ℃), minimum - 25 ℃

  • Altitude: no more than 3000m (coordinate with the manufacturer when it exceeds 3000m)

  • Air humidity: the average value of daily relative humidity shall not be greater than 95%, and the average value of monthly relative humidity shall not be greater than 90%

  • The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kV

Technical parameter

Rated voltage

kV

12

Power frequency withstand voltage

phase to phase/earth

kV

42

Power frequency withstand voltage

Between open contacts

kV

48

Impulse withstand voltage phase to phase/earth

kV

75

Impulse withstand voltage

Between open contacts

kV

85

Rated frequency

Hz

50

Rated current

A

630

Rated short-time withstand current (4s)

kA

20/25

Rated peak withstand current

kA

50/63

Rated active load breaking current

A

630

Rated closed loop breaking current

A

630

Mechanical lifetime

Ops

10000

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!