CJX8(B) Series AC Contactor in 50/60Hz Circuits

  • CJX8(B) Series AC Contactor in 50/60Hz Circuits

Key attributes

Brand Switchgear parts
Model NO. CJX8(B) Series AC Contactor
Rated normal current 16A
Rated frequency 50Hz
Series CJX8(B)

Product descriptions from the supplier

Description

Application

CJX(B) series AC contactor is suitable for the circuit of AC 50Hz (or 60Hz), rated working voltage up to 660V and rated working current up to 370A, used to make and break circuit in a far distance, it also can be formed into an electromagnetic starter with suitable thermal overload relay to protect the circuit against
possible overload.

The products are in conformity with such standards as GB 14048.4 and IEC 60947-4-1.

Main Technical Data

Type

Frame code

Rated insulation Voltage

Conventional thermal current

Rated working current - 380V

Rated working current - 660V

Max power of controllable motor - 380V

Max power of controllable motor - 660V

Operating frequency time/h - AC-3

Operating frequency time/h - AC-4

CJX8(B)-9

16

690

16

8.5

3.5

4

3

600

300

CJX8(B)-12

16

690

20

11.5

4.9

5.5

4

600

300

CJX8(B)-16

16

690

25

15.5

3.7

7.5

5.5

600

300

CJX8(B)-25

25

690

40

22

13

11

11

600

300

CJX8(B)-30

30

690

45

30

17.5

15

15

600

300

CJX8(B)-37

45

690

45

37

21

18.5

18.5

600

300

CJX8(B)-45

45

690

60

44

25

22

22

600

300

CJX8(B)-65

85

690

80

65

44

33

40

600

300

CJX8(B)-85

85

690

100

85

55

45

50

600

300

CJX8(B)-105

105

690

140

105

82

55

75

600

150

CJX8(B)-170

170

690

230

170

118

90

110

600

150

CJX8(B)-250

250

690

300

245

170

132

160

400

100

CJX8(B)-370

370

690

410

370

268

200

250

400

100

External And Installation Size

Type

A

B max

C

D

E

F

G

H min

CJX8(B)-105

118

154

137

140

35

6.5

6.5

15

CJX8(B)-170

134

165

152

150

40

6

7.5

15

CJX8(B)-250

167

207

193

190

50

7

8.5

15

CJX8(B)-370

202

252

221

220

60

7

8.5

15


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.