756kV 800kV 1050 kV 1100 kV 1150 kV 1200 kV dead tank SF6 circuit breaker source manufacturer

  • 756kV 800kV 1050 kV 1100 kV 1150 kV 1200 kV dead tank SF6 circuit breaker source manufacturer

Key attributes

Brand ROCKWILL
Model NO. 756kV 800kV dead tank SF6 circuit breaker source manufacturer
Rated voltage 800kV
Rated normal current 5000A
Rated frequency 50/60Hz
Series LW

Product descriptions from the supplier

Description

Description

As a pioneer and the first dedicated source factory in China's GIS tank circuit breaker sector, we have defined the initial standards for industry development with decades of technical heritage accumulated through in-depth cultivation. From core technology Research and Development to large-scale production, we have built a full-chain independent system. With our products' consistently leading performance and ultimate reliability, we have become a trusted choice in the field of power grid construction.

800kV Dead Tank SF6 Circuit Breaker is a high-performance ultra-high voltage device designed for critical power transmission systems. Featuring a robust dead tank structure, its live components are sealed in an SF6 gas-insulated metal casing, delivering superior arc extinction efficiency (100x faster than air) and dielectric strength (2-3x air’s at 1atm) to rapidly interrupt fault currents and ensure grid stability. The low-center-of-gravity design enhances seismic resistance, adapting to extreme climates and rugged terrains. Integrated with bushings and current transformers, it supports multi-function control for real-time measurement and protective switching. With a mechanical/electrical lifespan exceeding 30 years and a fully sealed design, maintenance frequency is minimized, cutting operational costs. Equipped with anti-misoperation interlocks and dual-insulation safeguards, it prioritizes personnel safety and system reliability. Ideal for UHV grids, power plants, and industrial applications, this breaker sets a benchmark for efficiency and durability in 800kV high-stress environments.

Main Features

  • Exceptional Arc Extinction and Insulation: Using SF6 gas as the medium, it enables rapid arc extinction and has strong insulation properties. It can quickly interrupt fault currents, ensuring stable operation under high - voltage conditions.

  • Robust Dead - tank Structure: With a dead - tank design, the live parts are sealed in a metal tank, providing resistance to vibration, dust, and moisture, and enabling adaptation to harsh environments.

  • Integrated Functional Configuration: Integrates components such as bushings and current transformers, with functions like measurement and protection, simplifying the system layout.

  • Long Service Life and Low Maintenance: Boasts long mechanical and electrical service lives. The sealed structure reduces component aging, resulting in a long maintenance cycle and low costs.

  • Multiple Safety Guarantees: Equipped with anti - misoperation interlocking devices and multiple insulation protections to ensure the safety of personnel and equipment.

Technical specifications

Among them, some SF6 tank circuit breakers cover non-standard voltage levels such as 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV, 756kV, and 800kV,1050 kV 1100 kV 1150 kV 1200 kV with a rated short-circuit breaking current of 50kA or 63kA, and support customization.

Rated voltage

kV

756kV  800kV 1050 kV 1100 kV 1150 kV 1200 kV

Rated current

A

5000

Rated frequency

Hz

50/60

Rated short - circuit breaking current

kA

50kA、63kA

Rated short - time withstand current and duration

kA/s

50/3

63/2

Rated peak withstand current

kA

135

171

Rated short - circuit making current

kA

135

171

Number of breaks


2

Rated lightning impulse withstand voltage (peak value)

To ground

kA

2100

Break

2100+650

Rated switching impulse withstand voltage (peak value)

To ground

kA

1550

Break

1300+650

Rated short - time power - frequency withstand voltage (effective value)

To ground

kA

960

Break

960+460

Documentation Resource Library
Restricted
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: How to choose the voltage level of high-voltage sulfur hexafluoride circuit breaker?
A:

1. Select the circuit breaker corresponding to the voltage level based on the power grid level
The standard voltage (12/24/40.5/72.5/126/170/245/363/420/550/800/1100kV) is matched with the corresponding nominal voltage of the power grid. For example, for a 35kV power grid, a 40.5kV circuit breaker is selected. According to standards such as GB/T 1984/IEC 62271-100, the rated voltage is ensured to be ≥ the maximum operating voltage of the power grid.
2. Applicable scenarios for non-standard customized voltage
Non standard customized voltage (11/22/44/52/132/230/275/300/345/400/380/765kV) is used for special power grids, such as the renovation of old power grids and specific industrial power scenarios. Due to the lack of suitable standard voltage, manufacturers need to customize according to power grid parameters, and after customization, insulation and arc extinguishing performance must be verified.
3. The consequences of selecting the wrong voltage level
Choosing a low voltage level can cause insulation breakdown, leading to SF leakage and equipment damage; Choosing a high voltage level significantly increases costs, increases operational difficulties, and may also result in performance mismatch issues.

Q: What are the core differences between live tank circuit breakers and tank circuit breakers?
A:
  1. The core differences between porcelain column circuit breakers and tank circuit breakers—two main structural types of high-voltage circuit breakers—lie in six key aspects.
  2. Structurally, porcelain column types are supported by porcelain insulation pillars, with open-layout components like arc extinguishing chambers and operating mechanisms. Tank types use metal-sealed tanks to encapsulate and highly integrate all core parts.
  3. For insulation, the former relies on porcelain pillars, air, or composite insulating materials; the latter combines SF₆ gas (or other insulating gases) with metal tanks.
  4. Arc extinguishing chambers are mounted on the top or pillars of porcelain columns for the former, while built inside metal tanks for the latter.
  5. In application, porcelain column types suit outdoor high-voltage distribution with a dispersed layout; tank types adapt flexibly to indoor/outdoor scenarios, especially space-constrained environments.
  6. Maintenance-wise, the former’s exposed components enable targeted repairs; the latter’s sealed structure reduces overall maintenance frequency but requires full inspections for local faults.
  7. Technically, porcelain column types offer intuitive structure and strong anti-pollution flashover performance, while tank types boast excellent sealing, high SF₆ insulation strength, and superior resistance to external interference.
Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Q: For non-standard circuit breakers in the 800kV range such as 756kV and 790kV, how to select the tank structure (single-break / double-break)? What are the special requirements for voltage equalization measures?
A:

The double-break structure is preferred, while the single-break structure is only suitable for scenarios with voltage ≤760kV and small short-circuit current. Special requirements for voltage equalization: ① The value of the voltage equalizing capacitor should be increased by 10%-15% compared with that of standard 800kV equipment (e.g., 2000pF for 756kV equipment and 1800pF for 800kV equipment); ② Adopt a double-ring nested voltage equalizing ring, with the ring diameter increased by 5%-8% compared with that of 800kV standard equipment; ③ The break spacing should be reduced in proportion to the voltage (e.g., 8%-10% reduction for 756kV compared with 800kV) to balance insulation performance and structural dimensions.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.