735kV 750kV 765kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation

  • 735kV 750kV 765kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation

Key attributes

Brand ROCKWILL
Model NO. 735kV 750kV 765kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation
Rated voltage 750kV
Rated frequency 50/60Hz
Rated capacity 500kVA
Series ODFPS

Product descriptions from the supplier

Description

Product Description:

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

The 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation is a critical component designed for the highest tiers of power transmission systems. Its robust oil-immersed cooling technology ensures stable thermal performance and long-term reliability under heavy loads. The unique three-winding configuration provides exceptional operational flexibility, enabling efficient power transfer and system interconnection. As a "no excitation" design, it offers superior reliability and simplified maintenance by eliminating the need for on-load tap-changing mechanisms, making it an ideal and dependable solution for ultra-high voltage (UHV) grid applications that demand unwavering performance.

This power transformer is fully compliant with international standards including IEC 60076-1, IEEE C57.12.00, ANSI C57.12.90, AS/NZS 60076.5 and EN 61558-1. It meets quality requirements and is widely adaptable to the operational needs of power grids in multiple overseas regions.

Product Characteristics:

  • Optimized Structural Design: Utilizes advanced computational analysis of electrical, magnetic, mechanical, and thermal behavior to ensure robust and reliable construction.

  • Superior Electrical Performance: Complies with IEC standards while offering customized solutions, with partial discharge levels significantly lower than IEC 60076-3 limits.

  • Enhanced Operational Reliability: Multi-physics field analysis optimizes insulation, amp-turns balance, and cooling, delivering strong resilience to overvoltage and short-circuit events while eliminating risks of local overheating.

  • Premium Component Selection: Provides an exceptional user experience with a clean appearance, leak-free construction, and maintenance-free operation—no core disassembly required.

Technical Parameters

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Among these, some autotransformers cover non-standard voltage levels including 121kV, 132kV, 138kV, 200kV, 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV and 756kV,  We also provide customization services.

Rated capacity (kVA)

334

500

500

700

Voltage combination and tapping range

HV (kV)

765/√3

Tapping range(kV)

230/√3±2×2.5%

345/√3±2×2.5%

LV (kV)

63

Vector group

La0I0

No-load loss(kW)

95

110

125

130

On-load loss(kW)

570

860

860

1225

No-load current (%)

0.15

0.15

0.15

0.15

Short-circuit impedance (%)

HV-MV14

HV-LV50

MV-LV33

HV ~MV 

19 ~ 22

HV-LV46

MV-LV

23~24

HV-MV14

HV-LV50

MV-LV33

HV-MV18

HV-LV58

MV-LV36

Capacity assignment (MVA)

334/334/100

500/500/150

500/500/150

700/700/233

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

Normal Service Conditions

(1) Altitude:  ≤1000m;

(2) Ambient temperature:Maximum temperature: +40℃;Maximum monthly average temperature: +30℃;Maximum yearly average temperature: +20℃;Minimum temperature: -25℃.

(3) Power supply: approximate sinusoidal wave, three-phase symmetrical approximately

(4) Installation site: indoor or outdoor, without the obvious contamination.Note: The transformer used in special conditions should be specified when ordered.

Introduction to Structure and Performance:

Core:

  • Adopting highest quality, non-aging, cold-rolled, grain-oriented, and high permeability silicon steel lamination silicon steel sheets.

  • Processed on the GEORG length-cutting line from Germany.

  • Fully mitred joint, step lapping and polyester tape binding structure making the transformer with low no-load losses and low noise level.

  • Placing vibration isolation pads between the body and the tank to reduce vibration that transmits to the tank.

Winding:

  • Winded by high-quality oxygen free copper with lower resistivity.

  • Processed and manufactured on horizontal winding machines and large CNC vertical winding machines from both radial and axial directions.

  • Reasonable transposition applied between paralleling wires, magnetic shielding used for guiding flux leakage when necessary to reduce the stray losses of the transformer.

  • Reasonable design of insulation structure improving the ability of withstanding overvoltage.

  • Optimizing the ampere turns distribution of the winding, increasing the radial support and axial compression of the winding, using the pre-densification of spacers, constant pressure drying, to resist the impulse current.

Tank:

  • Bell type or cover bolted type tank.

  • Carbon dioxide shielded welding process.

  • High-quality gaskets and the limit groove.

  • Strict leak detection test procedures.

Others:

  • Cold-weld connection technology leads to improve the cleanliness of active part.

  • The vacuum disassembly and the vacuum filling technology measures reduce the partial discharge level effectively and enhance the transformer operating reliability.

  • The structure of "Six Direction Positioning" between the active part and the tank assures that the transformer has a strong ability of anti-transportation impact or anti-earthquake.

  • Surface treatment and coating, fine processing to tank surface, 7 steps such as acid-washing and phosphating, etc. special anti-fouling paint, ensuring not falling off or rusting away.

 

FAQ
Q: How does the oil-immersed design of the 750kV Single-phase Autotransformer with Three Windings benefit its operation?
A:

The oil-immersed design uses insulating oil for two key functions: first, it provides excellent electrical insulation between windings and components; second, it acts as a cooling medium, dissipating heat generated during operation to ensure the transformer works within a safe temperature range, thus extending its service life.

Q: What is the significance of "no excitation" in the 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation?
A:

"No excitation" means the transformer can only adjust voltage when it is completely disconnected from the power grid (no load current). This design simplifies the structure, enhances reliability, and is suitable for scenarios where voltage regulation frequency is low and stable grid operation is prioritized.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.