72.5kV HV SF6 circuit breaker

  • 72.5kV HV SF6 circuit breaker

Key attributes

Brand ROCKWILL
Model NO. 72.5kV HV SF6 circuit breaker
Rated voltage 72.5kV
Rated normal current 5000A
Rated frequency 50Hz
Rated short circuit breaking current 50kA
Series LW36-72.5

Product descriptions from the supplier

Description

Product introduction

LW36-72.5 self-energy outdoor HV AC sulfur hexafluoride circuit breaker is an outdoor three-phase porcelain column electrical equipment mainly used in AC 50Hz or 60Hz, 72.5kV electricity systems in extremely cold regions (for electric stations in general regions and -42'℃ extremely cold regions). This product can be operated frequently and used as a connection circuit breaker.

Main characteristic

  • High performance -strong rated circulating ability: strong short circuit breaking ability up to 5500A. 50kA.

  • Long service life -electrical endurance: 50kAx21times; mechanical life: 10000 times.

  • Reliable breaking performance.

  •  Reliable sealing performance; Annual leakage of SF6 gas ≤0.5%.

  • Meeting the requirements of hard running environments -suitable for Class IV polluted environments.

  • Multi-structure forms-usually porcelain column type and handcart type.

Main technical parameters

image.png

image.png

image.png

image.png

Instructions on placing orders :  

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store motor and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

Documentation Resource Library
Restricted
Live Tank Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the differences between this product and similar products from ABB/Siemens?
A:

The LW10B \ lLW36 \ LW58 series products in the sample booklet are porcelain column SF ₆ circuit breakers based on the ABB'LTB series improvement, with voltage coverage of 72.5kV-800kV, using Auto Buffer ™ Self powered arc extinguishing technology or vacuum arc extinguishing technology, integrated spring/motor driven operating mechanism, supports various customized services, covering 40.5-1100kV full voltage levels, with outstanding modular design and strong customization ability, suitable for projects that require flexible adaptation to different power grid architectures. Made in China, with fast global service response speed, high logistics efficiency, and high reliability at a reasonable price.

Q: What are the core differences between live tank circuit breakers and tank circuit breakers?
A:
  1. The core differences between porcelain column circuit breakers and tank circuit breakers—two main structural types of high-voltage circuit breakers—lie in six key aspects.
  2. Structurally, porcelain column types are supported by porcelain insulation pillars, with open-layout components like arc extinguishing chambers and operating mechanisms. Tank types use metal-sealed tanks to encapsulate and highly integrate all core parts.
  3. For insulation, the former relies on porcelain pillars, air, or composite insulating materials; the latter combines SF₆ gas (or other insulating gases) with metal tanks.
  4. Arc extinguishing chambers are mounted on the top or pillars of porcelain columns for the former, while built inside metal tanks for the latter.
  5. In application, porcelain column types suit outdoor high-voltage distribution with a dispersed layout; tank types adapt flexibly to indoor/outdoor scenarios, especially space-constrained environments.
  6. Maintenance-wise, the former’s exposed components enable targeted repairs; the latter’s sealed structure reduces overall maintenance frequency but requires full inspections for local faults.
  7. Technically, porcelain column types offer intuitive structure and strong anti-pollution flashover performance, while tank types boast excellent sealing, high SF₆ insulation strength, and superior resistance to external interference.
Q: What is a live tank circuit breaker? What voltage level is it suitable for they?
A:

live tank circuit breaker is a structural form of high-voltage circuit breaker, which is characterized by the use of ceramic insulation pillars to support key components such as arc extinguishing chamber and operating mechanism. The arc extinguishing chamber is usually arranged on the top or pillar of the ceramic pillar. It is mainly suitable for medium and high voltage power systems, with voltage levels covering the range of 72.5 kV to 1100 kV. live tank circuit breakers are common control and protection equipment in outdoor distribution devices such as 110 kV, 220 kV, 550 kV, and 800 kV substations.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.