• 5kVA-1000kVA Solar isolation transformers
5kVA-1000kVA Solar isolation transformers
discuss personally
Model
SG-200kVA
SG-100kVA
SG-1000kVA
Basic info
Brand ROCKWILL
Model NO. 5kVA-1000kVA Solar isolation transformers
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SG
Product Detail

Product Overview

The transformer is the main component of various power supplies and electrical equipment, the transformer is composed of cylindrical windings and laminated iron cores, and the iron cores are stacked with new high-quality high-silicon silicon steel sheets and fully mitered joints. The company adopts advanced production technology, with imported Spanish winding machine and a full set of vacuum pressure impregnation equipment; The winding adopts the whole column winding method; Vacuum impregnation of the transformer to make the insulation grade of the transformer reach class F or H. The output and input voltages of the transformer can be designed according to customer needs.

Product features:

  • Scientific and reasonable design, the voltage change rate is controlled within 1~1.5%.

  • It is made of high-quality new silicon steel sheet, which can effectively reduce iron loss and improve efficiency.

  • It is made of high-quality wire rod with high temperature resistance, which minimizes its own loss and greatly improves the efficacy.

  • The use of H-class insulation, high temperature resistant insulation materials, improve the high voltage strength, insulation grade, and prolong the service life.

  • High efficiency design, up to more than 98%.

  • Patented design, beautiful, novel, high power density, small size, high space utilization.

  • The product chassis is divided into stainless steel and iron boxes, and there are inlet and outlet holes outside the box shell for the installation of power lines. If necessary, voltmeter, ammeter, temperature control alarm system, etc. can be added according to user requirements.

Technical data:

Product Advantages:

  • 100% full power.

  • Imported silicon steel sheet Low iron loss High magnetic induction strength.

  • LED display Clear and intuitive display.

  • Adopt high temperature resistant DM0.2 insulating paper Insulating sleeve 155°C.

  • Pure copper coil Wire two-layer insulating paint Low wire loss Not easy to oxidize.

  • The box has a built-in cooling fan,Intelligent control of temperature control meter .

  • The chassis is painted with the latest technology, and the rainproof design is IP65 certified.

Material description of transformer:

  • Iron core:Adopts new high-quality high-silicon silicon steel sheet, the main material is 0.35 thick H18, H14, H12, Z11 high-quality silicon steel sheet, we select the most suitable material according to customer requirements and use conditions, so that the transformer performance design to achieve the best. (The conventional material is a new high-quality silicon steel sheet).

  • The wire:Rod is made of PEW, UEW, EIW, SEIW, FEAI enameled wire and glass wire coated wire, and the temperature resistance level is F class (155 °C), H class (180 °C), HC class (200 °C), C class (220 °C). (The conventional temperature resistance level is H class 180°C).

  • Insulating material:High temperature resistant insulating paper is used as insulating material, which has multiple properties of high temperature insulation, flame retardant and moisture resistance.

  • Terminal block :The terminal block adopts the terminal block for small power, which is beautiful in appearance and has excellent voltage resistance, temperature resistance and flame retardant performance. The high power adopts high-quality copper bar.

  •  Iron feet:Mainly use CNC bending cold plate

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!