• 550kV 740kV Gas Insulated Switchgear HV (GIS)
550kV 740kV Gas Insulated Switchgear HV (GIS)
discuss personally
Model
ZF28-550/4000-63
Basic info
Brand ROCKWILL
Model NO. 550KV 740KV GIS SF6 insulated Switchgear
Rated voltage 550kV
Rated normal current 4000A
Series ZF28
Product Detail

Product Overview:
    ZF28-550 type GIS/ ZH28-550 type HGIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
    This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features and advantages of the product:

  • Fully spring mechanism, high reliability.

  • Excellent breaking ability.

  • The arc extinguish of CB adopts dual break structure, and shunt capacitor to balance the voltage between open contacts, which improves the breaking ability of short-line fault and the breaking current of short circuit is 63kA.

  • E2-M2-C2 circuit breaker; E2 electrical endurance; M2 mechanical endurance.

  • Strong rated current flow capacity.

  • Excellent insulation level, low partial discharge.

  • Excellent corrosion resistance.

  • Advanced Designing tool.

  • Basin-type insolator with aluminium flange; double sealing structure.

  • Strict assembly technology.

  • The domestic first high power spring operation mechanism of circuit breaker has the small volume and is safe and stable, free of maintenance. high reliable and conform to oil free and gas free requirements for operation mechanism.

  •  Interrupter unit adopts shunt capacitor to balance the voltage between open contacts It improves short line  fault breaking capability.

  • Excellent insulation level and low partial discharge. The only company in the industry that can achieve: under the 80% power-frequency withstand voltage (80%×740kV = 592kV), the partial discharge of intervals is lower than 5pC, the partial discharge of the insulator is lower than 3pC. It’s better than the IEC standard that the partial discharge should be lower than 5pC under 1.2 times phase voltage (1.2×550/√3 = 381kV).

  • The insulator quality is stable and reliable. The basin-type insulator pouring process reaches the international advanced level.

Technical Parameters:

image.png

What are the basic requirements for GIS operation?

  • Indoor SF6 equipment room that operators often enter: ventilate at least once per shift, ventilate for 15 minutes, the air exchange volume should be greater than 3-5 times the air volume, and the air outlet should be installed in the lower part of the room; Equipment places that are not frequently visited by operators: ventilate for 15 minutes before entering.

  • During operation, the induced voltage on the shell and frame of GIS should not exceed 36V for the parts that are easily accessible to operation and maintenance personnel.

  • Temperature rise: should not exceed 30K in the part that is easily accessible to operating personnel; The part that is easily accessible to the operator but not touched during operation should not exceed 40K; Individual parts that are not easily accessible to the operator should not exceed 65K.

  • SF6 switchgear inspection at least once a day, unattended substation inspection according to regulations. During the inspection, the visual inspection is mainly carried out, and the equipment is not abnormal, and a record is made.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!