• 33kv Oil Immersed Grounding /Earthing Transformer
33kv Oil Immersed Grounding /Earthing Transformer
discuss personally
Model
JDS-15240KVA-33KV
Basic info
Brand ROCKWILL
Model NO. 33kv Oil Immersed Grounding /Earthing Transformer
Rated voltage 33kV
Phases Three-phase
Frequency range 50/60Hz
Series JDS
Product Detail

Product Overview

Rockwill specializes in the design and manufacturing of 33kV oil immersed grounding transformers, engineered for reliable grounding protection in power systems. Our products comply with IEC and IEEE international standards, ensuring stable and safe operation of electrical networks.

Key Specifications

Product Highlights

Premium Core

The transformer core is made of high-quality cold-rolled oriented silicon steel sheets with 45° full diagonal joints. The iron yoke is securely clamped with through bolts, and the core columns are tied with fiberglass tape. The core surface is coated with silicone resin adhesive for moisture protection and noise reduction.

Superior Winding

The windings are constructed with high-quality copper conductors in a segmented cylindrical structure to enhance interlayer insulation. Vacuum drying technology is applied to ensure excellent electrical performance, high mechanical strength, and minimal partial discharge.

Advanced Insulation and Cooling

The oil immersed grounding transformer features a fully sealed tank with corrugated fins for efficient heat dissipation, eliminating the need for an oil storage tank. Oil tanks are sealed with oil-resistant rubber strips to prevent contact with air, preserving the insulating oil quality and extending transformer lifespan. Compact footprint, aesthetic appearance, and maintenance-free design are key benefits.

Comprehensive Protection Devices

Equipped with pressure relief valves, gas relays, and oil level gauges for real-time monitoring of oil condition. Temperature control devices support remote transmission, allowing convenient supervision of transformer operating temperature.

Technical Parameters

  • Transformer Type: Oil Immersed

  • Connection Groups: ZN (Zigzag)

  • Rated Voltage: Up to 36kV

  • Rated Current: Up to 3000A

  • Short Time Duration: 10s / 30s / 60s or customized

  • Cooling Method: ONAN, ONAF, AN, AF

  • Installation: Indoor / Outdoor

  • Ambient Temperature Range: -40°C to +40°C

  • Standards Compliance: IEC 60076-6, IEC 60076-1, IEEE

  • Enclosure Options: Transformer cabinet with customizable IP ratings, optional CT, VT, and isolation switch

Notes

  • Neutral short time current I0 = IG

  • Neutral zero-sequence impedance Z0 = Phase impedance / 3

  • ±5% off-load tap changer

  • Confirm Z0 value before production if not self-limiting

  • Z0 tolerance ≤ 10%

Rockwill 33kV Oil Immersed Grounding Transformers combine advanced engineering and strict quality control to deliver dependable grounding solutions for power networks worldwide. For inquiries and customization, please contact us.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
FAQ
Q: How does the Zig-Zag connection in your 33kV grounding transformer work?
A:
The Zig-Zag (ZN) winding provides a low-impedance path for ground fault currents while blocking normal load currents. During a fault, it creates opposing magnetic fluxes to limit current to safe levels (24.8A continuous/800A for 20s) while maintaining system stability and preventing overvoltage damage. Its zero-sequence impedance (Z₀) is precisely controlled within ≤10% tolerance to ensure reliable fault current limitation.
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!