Key attributes

Brand Vziman
Model NO. 33kV 34.5kV 35kV 36kV Three-phase Oil-immersed Power Distribution Transformer Original Manufacturer
Rated capacity 1000kVA
Series Distribution Transformer

Product descriptions from the supplier

Description

Product overview:

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

This power transformer is fully compliant with international standards including IEC 60076-1, IEEE C57.12.00, ANSI C57.12.90, AS/NZS 60076.5 and EN 61558-1. It meets quality requirements and is widely adaptable to the operational needs of power grids in multiple overseas regions.

  • High reliability of operation verification in more than 50 countries and regions around the world.

  • Mainly used in 33kV distribution network, industrial and mining enterprises and civil building power supply and distribution system.

  • Roducts are mainly exported to Southeast Asia, the Middle East, Africa, South America and other countries and regions.

  • Standards: IEC 60076 series, IEC 6013, IEC 60214-1, IEC 60296; Gb1094-1996, GB/T6451-2008, GB/T7597-2007, etc.

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Product advantages
Leading technology

  • High pressure copper tape winding technology, improve lightning resistance.

  • Low voltage copper foil winding technology, high quality A class insulation material insulation.

  • Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure.

The shell

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation .

winding

  •  Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  •  The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material

  •  Baowu Steel Group production of silicon steel sheet.

  •  High quality anaerobic copper from China.

  •  CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Other instructions

  •  The low-voltage outgoing terminal is tinned copper bar.

  •  The high-voltage outlet terminals are ring tinned bolts.

  •  Default no-load voltage regulator NLTC (OLTC can be customized) tap switch 5 or 7.

  • Transformers above 630KVA are protected by gas relays.

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc).

  • Other customization requirements (tap switch, color, oil pillow, etc).

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

  • Normal delivery period of 30 days, worldwide fast delivery.

What is high-voltage copper strip winding technology?

Definition:
High - voltage copper - tape winding technology refers to the use of copper tape as the winding material in the manufacturing of high - voltage transformers and reactors. The copper tape is wound layer by layer around the iron core or the bobbin through mechanical or automated equipment to form the required high - voltage winding. This technology can ensure the uniformity and compactness of the winding and improve the electrical performance and mechanical strength of the equipment.

Technical Features:

  • High Conductivity: Copper tape has excellent electrical conductivity, which can effectively reduce the resistance loss of the winding and improve the efficiency of the equipment.

  • Mechanical Strength: Copper tape has relatively high mechanical strength and can withstand the impact of high voltage and large current, improving the reliability and service life of the equipment.

  • Uniformity: Through precise winding processes, the uniform distribution of each layer of copper tape can be ensured, reducing the problems of local overheating and non - uniform electric field.

  • Compactness: Copper - tape winding can achieve a higher winding density, making the equipment more compact in volume and saving space.

  • Insulation Performance: During the copper - tape winding process, insulating materials can be added between each layer of copper tape to ensure good electrical insulation performance.


Documentation Resource Library
Restricted
Vziman IEC/ ANSI Oil-immersed Power transformer selection catalog
Catalogue
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How Often Should Transformers Be Overhauled?
    1. Transformer Major Overhaul Cycle The main transformer shall undergo a core-lifting inspection before being put into service, and thereafter a core-lifting overhaul shall be performed every 5 to 10 years. Core-lifting overhaul shall also be carried out if a fault occurs during operation or if issues are identified during preventive tests. Distribution transformers operating continuously under normal load conditions may be overhauled once every 10 years. For on-load tap-changing transformers, t
    12/09/2025
  • Adjustment and Precautions for H61 Oil Power 26kV Electric Transformer Tap Changers
    Preparatory Work Before Adjusting the Tap Changer of H61 Oil Power 26kV Electric Transformer Apply for and issue a work permit; carefully fill out the operation ticket; conduct a simulation board operation test to ensure the operation is error-free; confirm the personnel who will carry out and supervise the operation; if load reduction is required, notify affected users in advance. Before construction, power must be disconnected to take the transformer out of service, and voltage testing must be
    12/08/2025
  • H59/H61 Transformer Failure Analysis and Protection Measures
    1.Causes of Damage to Agricultural H59/H61 Oil-Immersed Distribution Transformers1.1 Insulation DamageRural power supply commonly uses a 380/220V mixed system. Due to the high proportion of single-phase loads, H59/H61 oil-immersed distribution transformers often operate under significant three-phase load imbalance. In many cases, the degree of three-phase load imbalance far exceeds the limits permitted by operational regulations, causing premature aging, deterioration, and eventual failure of th
    12/08/2025
  • What Is an H61 Distribution Transformer? Uses & Setup
    H61 distribution transformers refer to transformers used in power distribution systems. In a distribution system, high-voltage electricity must be converted into low-voltage electricity via transformers to supply electrical equipment in residential, commercial, and industrial facilities. The H61 distribution transformer is a type of infrastructure equipment primarily used in the following scenarios: Supplying power from high-voltage grids to low-voltage grids: During power delivery, high-voltage
    12/08/2025
  • How to Diagnose Faults in H59 Distribution Transformers by Listening to Their Sounds
    In recent years, the accident rate of H59 distribution transformers has shown an upward trend. This article analyzes the causes of failures in H59 distribution transformers and proposes a series of preventive measures to ensure their normal operation and provide effective assurance for power supply.H59 distribution transformers play a vital role in power systems. With the continuous expansion of power system scale and the increasing single-unit capacity of transformers, any transformer failure n
    12/08/2025
  • What lightning protection measures are used for H61 distribution transformers?
    What lightning protection measures are used for H61 distribution transformers?A surge arrester should be installed on the high-voltage side of the H61 distribution transformer. According to SDJ7–79 "Technical Code for Design of Overvoltage Protection of Electric Power Equipment," the high-voltage side of an H61 distribution transformer should generally be protected by a surge arrester. The grounding conductor of the arrester, the neutral point on the low-voltage side of the transformer, and the
    12/08/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.