• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


330~500kV Metal Oxide Surge Arresters

  • 330~500kV Metal Oxide Surge Arresters

Key attributes

Brand ROCKWILL
Model NO. 330~500kV Metal Oxide Surge Arresters
Rated voltage 420kV
Rated frequency 50/60Hz
Series Y10W

Product descriptions from the supplier

Description

Description

330~500kV Metal Oxide Surge Arresters are critical protective devices engineered for high-voltage power transmission and distribution networks operating within the 330kV to 500kV range. These arresters integrate high-performance metal oxide varistors (MOVs) into robust housings (typically composite or porcelain) to suppress transient overvoltages caused by lightning strikes, switching operations, or system faults. Installed near transformers, circuit breakers, and transmission line terminals, they divert excessive surge currents to the ground while clamping voltage levels to safe thresholds, safeguarding grid infrastructure from insulation damage and ensuring uninterrupted power supply.

Features

  • High-Voltage Optimization:Rated specifically for 330kV to 500kV systems, with electrical parameters precisely calibrated to handle the high-voltage stresses of bulk power transmission, ensuring compatibility with grid equipment in this voltage class.

  • Superior Surge Handling:Equipped with MOVs designed to absorb large surge energies from severe events like direct lightning strikes or substation faults, limiting voltage spikes to levels within the insulation tolerance of high-voltage equipment.

  • Fast Response Time:Ultra-rapid reaction to transient overvoltages (microsecond-scale) ensures minimal voltage overshoot, critical for protecting sensitive components like transformer windings and circuit breaker insulation.

  • Environmental Resilience:Housings (composite silicone rubber or high-strength porcelain) resist UV radiation, extreme temperatures, and pollution, making them suitable for harsh outdoor environments—from coastal areas to high-altitude regions.

  • Low Leakage Current:Minimal leakage current during normal operation reduces energy loss and heat generation, enhancing efficiency and extending the lifespan of both the arrester and connected grid equipment.

  • Mechanical Durability:Robust construction withstands mechanical stresses from wind, vibration, and installation, ensuring structural integrity even in high-voltage substations with heavy equipment and frequent maintenance activities.

  • Compliance with Global Standards:Meets international standards (e.g., IEC 60099-4, IEEE C62.11) for high-voltage arresters, undergoing rigorous testing for impulse withstand, thermal stability, and long-term reliability to ensure seamless integration into global power grids.

  • Easy Installation & Maintenance:Designed with standardized mounting interfaces and lightweight composite options (where applicable) to simplify installation. Stable performance minimizes the need for frequent inspections, reducing lifecycle costs.

Model

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times

 

 

 

 

 

(Peak Value

(Peak Value

(Peak Value

(Peak Value

 

Y10W1-300/727W

300

330

228

425

618

727

814

1500

10200

Y10W1-300/727(G)W

300

330

228

425

618

727

814

1500

12600

Y20W1-420/1046W

420

500

318

565

858

1046

1170

2000

15300

Y20W1-414/950W

414

500

318

557

785

950

1069

2000

18750

Y20W1-444/1106 (G)W

444

500

324

597

907

1106

1238

2000

18900

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Surge Arrester Monitoring: Trends, Challenges & Future Outlook
    1. Current Status and Shortcomings of Online MonitorsCurrently, online monitors are the most commonly used tools for surge arrester monitoring. While they can detect potential defects, they have significant limitations: manual on - site data recording is required, precluding real - time monitoring; and post - collection data analysis adds to operational complexity. IoT - based intelligent monitoring overcomes these issues—collected data is uploaded via the IoT to processing platforms,
    07/31/2025
  • Surge Arrester Handover & Live Testing Technologies for Reliable Power Grid Operation
    1. Overview of Surge Arrester Handover Test Technology1.1 Necessity of Handover TestThe handover test is a crucial step in ensuring the performance and safe operation of surge arresters within power systems. For power systems with voltage levels at 220 kV and below, surge arresters play a core role in protecting electrical equipment from damage caused by overvoltages and lightning strikes. However, during the process from the arrester leaving the factory to its actual operation after installatio
    07/31/2025
  • Surge Arrester Failure Analysis and Prevention: Key Causes of 10 kV Distribution Arresters' Malfunctions
    1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
    07/30/2025
  • Advanced Online Monitoring System for Zinc Oxide Surge Arresters: Key Technologies and Fault Diagnosis
    1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer. Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source. Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs). Process Layer: Features monitoring terminals for Potential Transformers (PTs) a
    07/30/2025
  • Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
    1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
    07/30/2025
  • Real-Time Monitoring of Surge Arresters in 10kV GIS Cubicles: Enhancing Railway Power System Safety
    1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo en
    07/30/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.