| Brand | ROCKWILL |
| Numero sa Modelo | 330~500kV Metal Oxide Surge Arresters Sa 330 hangtod sa 500kV Metal Oxide Surge Arresters |
| Naka nga boltahang rated | 420kV |
| Nasodnong peryedyo | 50/60Hz |
| Serye | Y10W |
Ang 330~500kV Metal Oxide Surge Arresters mao ang mga kritikal nga protective devices nga gihimo alang sa high-voltage power transmission ug distribution networks nga nagoperasyon sa 330kV hangtod 500kV range. Kini nga mga arresters nag-integrate og high-performance metal oxide varistors (MOVs) sa robust housings (typical nga composite o porcelain) aron pagpugos sa transient overvoltages nga resulta sa lightning strikes, switching operations, o system faults. Gisulod sila duol sa transformers, circuit breakers, ug transmission line terminals, ug nag-divert sila sa excessive surge currents ngadto sa ground habang nag-clamp sa voltage levels sa safe thresholds, protektado ang grid infrastructure gikan sa insulation damage ug sigurado ang uninterrupted power supply.
High-Voltage Optimization:Rated specifically for 330kV to 500kV systems, with electrical parameters precisely calibrated to handle the high-voltage stresses of bulk power transmission, ensuring compatibility with grid equipment in this voltage class.
Superior Surge Handling:Equipped with MOVs designed to absorb large surge energies from severe events like direct lightning strikes or substation faults, limiting voltage spikes to levels within the insulation tolerance of high-voltage equipment.
Fast Response Time:Ultra-rapid reaction to transient overvoltages (microsecond-scale) ensures minimal voltage overshoot, critical for protecting sensitive components like transformer windings and circuit breaker insulation.
Environmental Resilience:Housings (composite silicone rubber or high-strength porcelain) resist UV radiation, extreme temperatures, and pollution, making them suitable for harsh outdoor environments—from coastal areas to high-altitude regions.
Low Leakage Current:Minimal leakage current during normal operation reduces energy loss and heat generation, enhancing efficiency and extending the lifespan of both the arrester and connected grid equipment.
Mechanical Durability:Robust construction withstands mechanical stresses from wind, vibration, and installation, ensuring structural integrity even in high-voltage substations with heavy equipment and frequent maintenance activities.
Compliance with Global Standards:Meets international standards (e.g., IEC 60099-4, IEEE C62.11) for high-voltage arresters, undergoing rigorous testing for impulse withstand, thermal stability, and long-term reliability to ensure seamless integration into global power grids.
Easy Installation & Maintenance:Designed with standardized mounting interfaces and lightweight composite options (where applicable) to simplify installation. Stable performance minimizes the need for frequent inspections, reducing lifecycle costs.
Model |
Arrester |
System |
Arrester Continuous Operation |
DC 1mA |
Switching Impulse |
Nominal Impulse |
Steep - Front Impulse |
2ms Square Wave |
Nominal |
Rated Voltage |
Nominal Voltage |
Operating Voltage |
Reference Voltage |
Voltage Residual (Switching Impulse) |
Voltage Residual (Nominal Impulse) |
Current Residual Voltage |
Current - Withstand Capacity |
Creepage Distance |
|
kV |
kV |
kV |
kV |
kV |
kV |
kV |
A |
mm |
|
(RMS Value) |
(RMS Value) |
(RMS Value) |
Not Less Than |
Not Greater Than |
Not Greater Than |
Not Greater Than |
20 Times |
|
|
|
|
|
|
(Peak Value |
(Peak Value |
(Peak Value |
(Peak Value |
|
|
Y10W1-300/727W |
300 |
330 |
228 |
425 |
618 |
727 |
814 |
1500 |
10200 |
Y10W1-300/727(G)W |
300 |
330 |
228 |
425 |
618 |
727 |
814 |
1500 |
12600 |
Y20W1-420/1046W |
420 |
500 |
318 |
565 |
858 |
1046 |
1170 |
2000 |
15300 |
Y20W1-414/950W |
414 |
500 |
318 |
557 |
785 |
950 |
1069 |
2000 |
18750 |
Y20W1-444/1106 (G)W |
444 |
500 |
324 |
597 |
907 |
1106 |
1238 |
2000 |
18900 |