• 3.6kV-24kV Indoor metal-clad withdrawable switchgear MV Switchgear
3.6kV-24kV Indoor metal-clad withdrawable switchgear MV Switchgear
discuss personally
Model
KYN28-7.2/1250-40
KYN28-3.6/630-40
KYN28-12/1250-50
KYN28-12/2500-3
Basic info
Brand ROCKWILL
Model NO. 3.6KV-24KV Indoor metal-clad withdrawable switchgear MV Switchgear
Rated voltage 24kV
Series KYN28-12
Product Detail

Description:

China KYN28-12 indoor metal-clad withdrawable switchgear (hereinafter short as switchgear) is a complete power distribution device for 3.6~24kV,3-phase AC 50Hz,single-bus and single-bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc.,so as to control, protect and monitor the system. The switchgear meets IEC298,GB3906-91.In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB,3AH5 from Siemens domestic ZN65A,and VB2 from GE, etc.,it is truly a power distribution device with good performance. In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  •  Altitude no higher than 2500m.

  • The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

image.png

Structure & Basic Components of Switchgear:

image.png

Overall size and weight:

image.png

Notice:

when the rated current is more than 1600A, cubicle width shall de 1000 mm, and cubicle height will be 1660mm and for schema of rear overhead line in.

  • Width of cabinet:650mm(compound insulation)or 800mm(air insulation) at current<1250A.

  • Width of cabinet:1000mm at current>1250A.

  • Depth of cabinet:1400mm,at cabinet width of 650mm(compoud insulation)when employing theconfiguration of incoming and outgoing cables.

  • Depth of cabinet:1500mm,at cabinet width of 6800mm(air insulation)when employing theconfiguration of incoming and outgoing cables.

  • Depth of cabinet:1600mm,when employing the configuration of rear overhead incoming andoutgoing cables.

    image.png

Structure Features:

image.png

Compartment:
Busbar compartment; circuit breaker compartment; cable compartment; low-voltage compartment.

  •  Main device: circuit breaker, contactor.

  •  Current transformers.

  •  Earthing switch.

  •  Voltage transformers.

  •  Support-bushing insulators.

  •  Bushing insulators.

  • Surge arresters.

  • Support insulators (reactance).

  • Main busbars.

  • Connecting (distribution) busbars.

  • Earth-fault current transformer.

  • Earthing conductor.

  • Metal movable particions.

  • Cable ducts (optionally).

  • Vent flaps.

Dimension:

image.png
Dimension in brackets means dimension of heavy-current cubicle.

image.png

What are the application scenarios of indoor metal armored pull-out switch cabinets? 

Industrial Applications:

  • In Industrial Enterprises:

  • Widely used in factories, mines, metallurgy, and chemical industries. They provide medium-voltage power distribution and protection for various production equipment such as large motors, transformers, and electric furnaces. For example, in a steel mill's rolling workshop, medium-voltage switchgear provides reliable power supply to the rolling motors and can quickly cut off the circuit in case of motor overload or short circuit, protecting the motor and the entire production line.

Commercial Buildings and Public Facilities:

  • In Commercial Buildings (e.g., shopping centers, office buildings, hotels) and Public Facilities (e.g., hospitals, schools, stadiums):

  • Used in medium-voltage distribution rooms. They provide power distribution and control for equipment within the buildings, such as elevators, air conditioning, and lighting. For instance, in a hospital, medium-voltage switchgear supplies stable power to various medical equipment and air conditioning systems, ensuring the normal operation of the hospital.

Substations:

  • In Medium-Voltage Substations:

  • Serves as the primary distribution equipment, receiving and distributing power from transmission lines. It can step down the medium-voltage power from the transmission lines and distribute it to various low-voltage lines, or distribute the power to other substations or end-users.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!