24kV SF6 Ring Main Unit Switchgear

  • 24kV SF6 Ring Main Unit Switchgear

Key attributes

Brand ROCKWILL
Model NO. 24kV SF6 Ring Main Unit Switchgear
Rated voltage 24kV
Rated frequency 50/60Hz
Series RMU

Product descriptions from the supplier

Description
Description

The ring main unit switchgear uses SF6 gas as arc extinguishing and insulating medium.

The switchgear is a fully sealed and fully insulated structure. Busbars, switches and live parts are completely enclosed in stainless steel housings.

The protection level reaches IP67.

Switchgear has a complete "five protection" interlocking device to prevent personnel and equipment malfunctions that may be caused by human misoperation.

All switchgears have reliable safety relief channels to ensure operator safety even in extreme situations.

The switchgear is divided into two types: fixed unit combination and expandable unit combination.

The switchgear usually enters and exits the cable from the front, and can also realize the side exit or side expansion according to different installation positions.

The size of the cabinet is easy to install, and it can be suitable for places with small space and poor environmental conditions.Electric, remote control and monitoring devices can be configured according to the different needs of users.

Feature

  • 24kV-class high-efficiency insulation: Utilizes SF₆ gas as the insulating medium, with insulation strength adapted to the 24kV voltage level and excellent arc-extinguishing performance. It can stably block current leakage in high-voltage environments, significantly reducing the risks of short circuits and flashovers, and ensuring the reliable operation of medium-voltage power grids.
  • Compact space adaptation: Boasts a small and compact structural design with a small footprint, making it particularly suitable for space-constrained scenarios such as urban distribution stations and industrial parks. It simplifies installation layouts while improving site utilization.
  • Multiple safety guarantees: Equipped with complete mechanical and electrical interlocking devices to prevent misoperations and incorrect switching; features a built-in SF₆ gas leakage monitoring system that provides real-time warnings of leakage risks. It complies with international medium-voltage equipment safety standards to ensure safety during operation and maintenance.
  • Low maintenance and long service life: The fully sealed gas chamber design effectively isolates dust, moisture, and corrosive substances, reducing erosion of internal components by the external environment. It enables long-term maintenance-free operation with a service life of over 20 years, significantly lowering the whole-life-cycle cost.
  • Flexible power distribution compatibility: Supports multiple wiring methods such as ring network and radial types, and can be quickly connected with 24kV-class transformers, cables, and other equipment. It adapts to the topological requirements of different medium-voltage distribution networks, meeting diverse power supply scenarios including urban power grids and large industrial plants.
  • Balance of environmental protection and economy: SF₆ gas is recyclable and reusable, reducing resource waste; the equipment has low operating energy consumption, and long-term usage costs are controllable, balancing environmental protection requirements and project economic benefits.
 
 

Normal working conditions

  • Applicable altitude: 1000m~4000m
  • Applicable temperature: -40ºC ~ +45ºC
  • Relative humidity: daily average ≤95%, monthly average ≤90%
  • Earthquake damage level: ≤8
Documentation Resource Library
Restricted
24kV SF6 Gas insulated Ring Main Unit (RMU) Brochure
Brochure
English
Consulting
Consulting
Restricted
SEC SPECIFICATIONS FOR 13.8.33.34.5kV RING MAIN UNIT-SRMU
Other
English
Consulting
Consulting
Restricted
Metropolitan Electricity Authority Technical Specification NO.108 for 12/24kV Ring Main Units
Other
English
Consulting
Consulting
Restricted
Bidding Document Supply, Test and Commissioning of MV Switching Stations (RMU) for Addis Ababa Distribution Network
Other
English
Consulting
Consulting
Restricted
EEHC Distribution materials specification for 24kv ring mian units
Other
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.