15kV 15.5kV 22kV 27kV 38kV Three-Phase Automatic Circuit Recloser/ reclosure with ADVC Controller

  • 15kV 15.5kV 22kV 27kV 38kV Three-Phase Automatic Circuit Recloser/ reclosure with ADVC Controller

Key attributes

Brand Schneider
Model NO. 15kV 15.5kV 22kV 27kV 38kV Three-Phase Automatic Circuit Recloser/ reclosure with ADVC Controller
Rated voltage 15kV
Series N-Series

Product descriptions from the supplier

Description

 Overview

As the pioneer and first professional OEM in China’s recloser industry, we’ve built robust R&D and manufacturing capabilities over decades, and set the industry’s original standards with groundbreaking achievements.

The Three-Phase Automatic Circuit Recloser/ reclosure with ADVC Controller is designed around vacuum interrupters contained in a fully welded and sealed 316 marine-grade stainless steel enclosure. The N-Series ACR is designed around vacuum interrupters contained in a fully welded and sealed 316 marine grade stainless steel enclosure.  The enclosure is filled with sulphur hexafluoride (SF6) gas or dry air (‘N-green’ option), which both have excellent electrical insulating properties, resulting in a compact and low-maintenance device.  

ADVC Features

Each recloser is provided with an operator interface. From here a user can access and program the many measurement and protection features available. The two following operator 
interfaces are available:  

SetVUE Operator Interface 
Based on the field-proven operator panels in the previous controllers, this menu-driven interface with large LCD display offers a familiar look and feel.

 

 FlexVUE Operator Interface

  •  20 Status Lights provide a quick snapshot of the protection and controller status. 

  • 12 Quick Action Keys are available to execute frequently used actions such as «Remote control» ON/OFF, «Reclose» ON/OFF, etc. Each key has its own status light to indicate the ON/OFF state. 

  • All Status Lights and Quick Action Keys are customizable. 

  • It is possible to access event and measurement data and change settings. 

 N-Series Recloser Specifications

The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 400000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 400000000
Services
Business Type: Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • EcoStruxure™ Connected solutions
    What is EcoStruxure™ ?EcoStruxure™ is our open, interoperable, IoT-enabled system architectureand platform. EcoStruxure delivers enhanced value around safety, reliability,efficiency, sustainability, and connectivity for our customers. EcoStruxureleverages advancements in IoT, mobility, sensing, cloud, analytics, andcybersecurity to deliver Innovation at Every Level. This includes ConnectedProducts, Edge Control, and Apps, Analytics & Services, which are supported byCustomer Lifec
    04/23/2025
  • RM6 SeT Digital solutions
    Digital solutionsDistributed DTU Easergy T300Comprehensive features and flexbile scalabilityTailored to meet future operational challenges ofdistribution network automationApplications range from monitoring rooms tomedium and low voltage distribution stationsTH110-R cable joint temperature measurementWireless passive, easy to installDirect measurement of conductor temperaturewith high accuracyPD110 series local discharge test deviceReal-time monitoring of equipment corona andpartial discharge st
    04/30/2025
  • Your trusted partner for wind turbine and wind farm solutions
    Solutions overviewControl of the wind turbineEnsure an optimized operating environmentGain greater control of the turbine through automation and backup powerChoosing the most efficient wind turbine is the key to success. Schneider Electric offers a fully automated wind turbine with the programmablelogic controller (PLC) and a highly-reliable UPS. They have a very low power consumption, and can be easily modified or upgraded.As such, the PLC functions as the “brain” of the wind turbin
    05/05/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.