• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


110kV-220kV Auxiliary Transformer(Transformer for generation)

  • 110kV-220kV Auxiliary Transformer(Transformer for generation)

Key attributes

Brand ROCKWILL
Model NO. 110kV-220kV Auxiliary Transformer(Transformer for generation)
Rated frequency 50/60Hz
Series S

Product descriptions from the supplier

Description

Description of Aux Transformer

An Auxiliary Transformer (Aux Transformer) is a specialized low-to-medium voltage transformer designed to supply reliable power to auxiliary systems in industrial facilities, power plants, substations, and large commercial complexes. Its core function is to step down high-voltage electricity (typically 10kV–35kV) from the main grid or generator to low-voltage levels (380V/220V) suitable for auxiliary equipment, such as pumps, fans, lighting, control systems, and communication devices. These auxiliary systems, though not directly involved in primary power generation or transmission, are critical for maintaining the overall operational efficiency, safety, and stability of the facility.

In normal condition the standing by transformer stays in hot condition, i.e. high voltage side is charged. Once any problem happens to the main transformer, the standing by transformer will be put in operation, which is for internal use only.

Features of Aux Transformer

  • Reliability-Focused Design: Built to ensure continuous operation, with many configurations including backup units to prevent downtime caused by primary transformer failures. This redundancy is vital for facilities where auxiliary power loss could disrupt critical processes.

  • Wide Voltage Adaptability: Primary side voltage matches the facility’s main power source (e.g., 10kV grid), while secondary side outputs standard low voltages (380V three-phase for machinery, 220V single-phase for lighting/controls) to align with auxiliary equipment requirements.

  • Compact and Space-Efficient: Compared to main transformers, Aux Transformers have smaller capacities (typically 50kVA–2000kVA) and a compact structure, making them suitable for installation in confined spaces like switchgear rooms or auxiliary power rooms.

  • Enhanced Protection Mechanisms: Equipped with built-in safeguards such as overcurrent protection, short-circuit protection, and temperature monitoring to protect both the transformer and connected auxiliary loads.

  • Durability in Diverse Environments: Designed to withstand industrial conditions, including dust, vibration, and moderate temperature fluctuations. Oil-immersed variants resist moisture, while dry-type models (epoxy-cast) are ideal for indoor, low-maintenance settings.

  • Efficiency for Low-Load Operations: Optimized for partial or varying loads (common in auxiliary systems) with low no-load losses, ensuring energy efficiency even when power demand is not at peak levels.

FAQ for
Q: What are the core international and domestic standards governing power transformers up to 345kV, and what are their respective focuses?
A:
Currently, mainstream standards are divided into three categories: international general standards, North American regional standards, and Chinese national standards. The core content and focus differences are as follows:
  • IEC 60076 series: The core international standard for power transformers, comprehensively covering key aspects such as design, testing, insulation requirements, and cooling systems. It serves as an important reference for national standard formulation in various countries.
  • IEEE C57 series (including ANSI C57): The dominant standard in North America, covering similar aspects of design, manufacturing, and testing as IEC 60076. It is tailored to the technical characteristics of North American power grids.
  • GB standards (e.g., GB20052-2013): Chinese national standards, most of which are harmonized with IEC standards. They propose specific requirements for efficiency and operational performance to ensure compatibility with China's power system.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • Analysis of Four Major Power Transformer Burnout Cases
    Case OneOn August 1, 2016, a 50kVA distribution transformer at a power supply station suddenly sprayed oil during operation, followed by burning and destruction of the high-voltage fuse. Insulation testing revealed zero megohms from the low-voltage side to ground. Core inspection determined that damage to the low-voltage winding insulation had caused a short circuit. Analysis identified several primary causes for this transformer failure:Overloading: Load management has historically been a weak
    12/23/2025
  • Commissioning Test Procedures for Oil-Immersed Power Transformers
    Transformer Commissioning Tests Procedures1. Non-Porcelain Bushing Tests1.1 Insulation ResistanceSuspend the bushing vertically using a crane or support frame. Measure the insulation resistance between the terminal and the tap/flange using a 2500V insulation resistance meter. The measured values should not deviate significantly from factory values under similar environmental conditions. For capacitor-type bushings rated 66kV and above with voltage sampling small bushings, measure the insulation
    12/23/2025
  • Purpose of Pre-Commissioning Impulse Testing for Power Transformers
    No-Load Full-Voltage Switching Impulse Testing for Newly Commissioned TransformersFor newly commissioned transformers, besides conducting necessary tests according to handover test standards and protection/secondary system tests, no-load full-voltage switching impulse tests are typically performed before official energization.Why Perform Impulse Testing?1. Check for Insulation Weaknesses or Defects in the Transformer and Its CircuitWhen disconnecting a no-load transformer, switching overvoltages
    12/23/2025
  • What are the classification types of power transformers and their applications in energy storage systems?
    Power transformers are core primary equipment in power systems that realize electrical energy transmission and voltage conversion. Through the principle of electromagnetic induction, they convert AC power of one voltage level to another or multiple voltage levels. In the transmission and distribution process, they play a critical role in "step-up transmission and step-down distribution," while in energy storage systems, they perform voltage step-up and step-down functions, ensuring efficient pow
    12/23/2025

Related Solutions

  • Implementation Scheme for Installing Lightning Arresters or Voltage Transformers in Gas-Insulated Ring Main Units
    According to insulation type, ring main units (RMUs) can be categorized as gas-insulated or air-insulated. The former installs primary circuit components in a sealed metal enclosure filled with low-pressure gas (primarily SF₆ or mixed gases) as the insulating medium, using cable terminals for incoming and outgoing lines. Due to superior insulation, compact size, and modular design, they are widely used in 10kV outdoor distribution substations and prefabricated transformer stations. However, thei
    08/16/2025
  • High-Temperature Insulating Material Solution for Electric Furnace Transformers
    Background & Challenge​Electric furnaces operate for extended periods under harsh conditions involving high temperatures, dust, etc. Traditional transformer insulation materials experience accelerated aging in these environments, leading to insulation failure, reduced lifespan, and even unplanned furnace shutdowns, significantly impacting production efficiency.​Core Strategy​Implement a dual-pronged approach to ensure transformer reliability and long-term operation under extreme high tempera
    08/09/2025
  • Eco-Friendly Electric Furnace Transformer Solutions
    Eco-Friendly Electric Furnace Transformer Solutions​Eco-friendly electric furnace transformers have become key equipment driving the green transformation of the electric furnace smelting industry. This solution, through innovative design and strict material selection, establishes an environmentally friendly system covering the product's entire life cycle:​Core Eco-Material Applications:​​​Halogen-Free Flame-Retardant Insulation Materials:​​ Fully adopts halogen-free materials such as ceramifiabl
    08/09/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.