• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


10kV 35kV Amorphous Alloy Dry-type Transformers

  • 10kV 35kV Amorphous Alloy Dry-type Transformers

Key attributes

Brand ROCKWILL
Model NO. 10kV 35kV Amorphous Alloy Dry-type Transformers
Rated voltage 35kV
Rated frequency 50/60Hz
Rated capacity 1250kVA
Series SCB

Product descriptions from the supplier

Description

Product Introduction

Since its advent in the 1970s, the amorphous alloy transformer, leveraging its innovative technology, has gradually become a new generation of high - efficiency and energy - saving power transformer. Compared with the traditional silicon steel sheet core transformer, the amorphous alloy transformer reduces the no - load loss by 70% - 80%, and the no - load current is significantly reduced by about 85%. This excellent performance not only significantly improves the energy utilization efficiency, but also shows obvious advantages in terms of safety such as fire prevention and explosion protection, making it the most energy - saving distribution transformer today.

Scope of Application
Suitable for places with low power distribution efficiency and high safety requirements, such as rural power grids, high-rise buildings, commercial areas, subways, airports, stations, industrial enterprises, and power plants.

Product Description

  • High-efficiency Amorphous Alloy Strips: Amorphous alloy strips are produced through a rapid cooling process that solidifies molten metal, resulting in an amorphous molecular structure. Their hysteresis loss and no-load current are significantly lower than those of silicon steel sheets, providing superior electromagnetic performance and energy efficiency.

  • Significant Energy Savings: Compared with silicon steel sheet transformers, amorphous alloy transformers reduce no-load loss by 70%-80% and no-load current by 85%, greatly improving energy efficiency. They are ideal for places with high energy-saving requirements.

  • Comparison with Traditional Transformers: Compared to traditional dry-type transformers, amorphous alloy transformers perform better in energy saving, temperature rise control, and noise reduction, ensuring efficient and safe fulfillment of power needs.

  • Precision Production Process: Through precise production of amorphous alloy strips and unique heat treatment techniques, the stability and excellent performance of the core material are ensured, guaranteeing the transformer’s long-term reliable operation.

  • Long Service Life and Low Maintenance: Due to low loss and low temperature rise, amorphous alloy transformers have a service life of over 20 years, reducing costs related to equipment maintenance and replacement.

  • Environmental Protection and Safety: Amorphous alloy transformers use eco-friendly materials, featuring excellent flame retardancy, high-temperature resistance, and low noise, making them suitable for places with strict environmental requirements.

Main parameters

Rated capacity

10 kVA ~ 5000 kVA

Rated input voltage

10 kV, 35 kV, 110 kV

Rated output voltage

400 V, 230 V

The decline in no - load losses

70% ~ 80%

The no - load current decreased

About 85%

Executive Standards

GB/T 1094

Power transformers

IEC 60076

International standard for transformers

ISO 9001

Quality management system

GB/T 19212

Energy saving technical requirements for power transformers

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.