10kV class S (B) H15 series amorphous alloy distribution transformer

  • 10kV class S (B) H15 series amorphous alloy distribution transformer

Key attributes

Brand ROCKWILL
Model NO. 10kV class S (B) H15 series amorphous alloy distribution transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 1250kVA
Series S (B) H

Product descriptions from the supplier

Description

Product Description

The 10kV class S(B) H15 series amorphous alloy distribution transformer represents a leap forward in energy-efficient power distribution technology. Engineered with a core of advanced amorphous metal, this transformer series is designed to achieve ultra-low no-load losses, significantly reducing electricity waste and operational costs. Ideal for utility grids, commercial complexes, and industrial plants, the S(B) H15 series offers exceptional reliability and a rapid return on investment by minimizing the total cost of ownership over its entire lifecycle. It sets a new standard for eco-friendly and economically viable electrical infrastructure.

Key Features

  • Features an H15 grade amorphous alloy core that reduces no-load losses by 60-80% compared to conventional silicon steel transformers, translating directly into lower electricity costs.

  • Ultra-low no-load losses ensure the lowest total cost of ownership over its entire service life, offering an excellent return on investment despite a slightly higher initial capital outlay.

  • Drastically reduced energy consumption leads to a lower carbon footprint. As a dry-type transformer, it is oil-free, flame-retardant, and explosion-proof, making it safer and more environmentally friendly.

  • The amorphous core is inherently resilient to mechanical stress and offers strong short-circuit resistance. An optimized magnetic circuit design ensures quiet operation below standard limits, suitable for noise-sensitive areas.

  • Designed and manufactured in compliance with international standards (IEC, IEEE) and relevant Chinese National Standards (GB), guaranteeing global applicability, reliability, and high quality.

Product model

  • S: Three-phase

  • (B): Low-voltage Foil Winding

  • H: Amorphous Alloy

  • 15: Performance Level Code

  • M: Hermetically Sealed

  • First □: Rated Capacity (kVA)

  • Second □: Rated High Voltage

Performance Parameters - Technical Parameters of S (B) H15-M Series Oil-Immersed Distribution Transformer

Rated Capacity

Voltage Combination and Tap Range

Connection Group

No-load Loss (W)

Load Loss at 120℃ (W)

Short-circuit Impedance %

No-load Current %

Outline Dimensions

(Length * Width * Height mm)

Total Weight (kg)

High Voltage kV

Tap Range %

Low Voltage kV

30

6

6.3

6.6

10

10.5

11

±5±2×2.5


0.4

Yyno

Dyn11

33

600

4.0

 

1.7

1100 * 690 * 1090

630

50

43

870

1.3

1190 * 750 * 1140

710

63

50

1040

1.2

1250 * 750 * 1160

750

80

60

1250

1.1

1290 * 750 * 1160

810

100

75

1500

1

1260 * 800 * 1190

870

125

85

1800

0.9

1320 * 870 * 1220

940

160

100

2200

0.7

1370 * 810 * 1220

1050

200

120

2600

0.7

1410 * 800 * 1320

1140

250

140

3050

0.7

1490 * 810 * 1360

1290

315

170

3650

0.5

1520 * 790 * 1430

1500

400

200

4300

0.5

1670 * 820 * 1510

1710

500

240

5150

0.5

1650 * 910 * 1450

1960

630

320

6200


0.3

1830 * 920 * 1440

2250

800

380

7500

0.3

1910 * 950 * 1500

2730

1000                     

450

10300

0.3

2000 * 1100 * 1490

3300

1250

530

12000

0.2

2100 * 1100 * 1580

3560

1600

630

14500

0.2

2120 * 1240 * 1560

3830

Note: the above parameters are only for typical values, and can be customized according to customer requirements.

Implementation criteria: GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2008, GB/T6451-2008

Conditions of use

  • No more than 1000m indoor or outdoor

  • The highest ambient air temperature is +40℃, the highest daily average temperature is +30℃.

  • Maximum annual average temperature +20℃ minimum temperature -25℃

  • According to user requirements, transformers can be operated under special conditions.

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.