• 10kV (Three Circuits) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit
10kV (Three Circuits) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit
discuss personally
Model
XGN99-12/630-20/25-BBB
Basic info
Brand ROCKWILL
Model NO. 10kV (Three Circuits) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit
Rated voltage 12kV
Rated frequency 50/60Hz
Series XGN
Product Detail

Description

The 10kV (Three Circuits) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit is a high-performance medium-voltage power distribution solution engineered to support three independent power supply loops. Operating at a rated voltage of 10kV, it features a normal-pressure sealed enclosure that uses air as the primary insulating medium—eliminating the need for SF₆ gas or pressurized systems. This switchgear integrates switching, protection, and control functions, making it ideal for scenarios demanding robust multi-loop power distribution, such as industrial complexes, urban substations, commercial hubs, and critical infrastructure requiring redundant power supply.

Key Features

  • Three-Circuit Configuration: Supports three separate power loops, enabling flexible power distribution, seamless load switching, and enhanced redundancy. This design minimizes downtime by ensuring continuity even if one loop requires maintenance or experiences a fault.

  • Normal Pressure & Air Insulation: Operates at atmospheric pressure with air as the insulating medium, eliminating risks of gas leakage, environmental pollution, or the need for gas refilling. This reduces long-term maintenance costs and aligns with eco-friendly standards.

  • Sealed Enclosure: A hermetically sealed structure protects internal components from moisture, dust, corrosive substances, and external debris, ensuring stable performance in harsh or variable environments (e.g., high humidity, industrial zones).

  • Compact & Space-Efficient: Optimized modular design with a reduced footprint compared to traditional multi-circuit switchgears, making it suitable for installations with limited space, such as urban substations or indoor distribution rooms.

  • High Safety & Reliability: Equipped with mechanical interlocks, anti-misoperation mechanisms, and visible isolation points to prevent accidental contact with live parts. The enclosed design also mitigates arc flash risks, enhancing operator safety.

  • Low Maintenance: Simplified mechanical components with a long service life (up to 10,000 operations) and no need for gas monitoring or refilling, reducing operational disruptions and lifecycle costs.

  • Scalable Integration: Compatible with smart grid systems, supporting remote monitoring and control. Its modular structure allows easy on-site installation and future expansion, adapting to evolving power distribution needs.

Name

Unit

Parameter Value

Rated Voltage (Ur)

kV

12

Rated Frequency (fr)

Hz

50

Rated Current (Ir)

A

630

Short - time Power Frequency Withstand Voltage (Ud)

Between Fractures

kV

48

Between Phases

kV

42

Phase to Ground

kV

42

Lightning Impulse Withstand Voltage (Up)

Between Fractures

kV

95

Between Phases

kV

75

Phase to Ground

kV

75

Rated Short - time Withstand Current (Ik)

kA

20/25

Rated Short - circuit Duration (tk)

s

4

Rated Peak Withstand Current (Ip)

kA

50/63

Rated Short - circuit Breaking Current (Isc)

kA

20/25

Rated Short - circuit Making Current (Ima)

 

Vacuum Interrupter

kA

50/63

Earthing Switch



Auxiliary Circuit and Control Circuit

Rated Voltage (Ua) DC/AC

V

≤400

Power Frequency Withstand Voltage (1min)

V

2000

Mechanical Life

 

Circuit Breaker

Times

10000

Disconnecting Switch

Times

3000

Earthing Switch

Times

3000

Electrical Life  

Circuit Breaker

Class

E2

Earthing Switch

Class

E2

Protection Grade of Cabinet Enclosure


IP4X

Protection Grade of Sealed Box


IP65

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!