• 10.5kV Silicon Steel Dry Type Distribution Transformer 630kVA/800kVA/1000kVA/1250kVA /1600kVA/2000kVA
  • 10.5kV Silicon Steel Dry Type Distribution Transformer 630kVA/800kVA/1000kVA/1250kVA /1600kVA/2000kVA
10.5kV Silicon Steel Dry Type Distribution Transformer 630kVA/800kVA/1000kVA/1250kVA /1600kVA/2000kVA
discuss personally
Model
SCB-10.5KV-2000KVA
SCB-10.5KV -1600KVA
SCB-10.5KV-1250KVA
SCB-10.5KV-1000KVA
SCB-10.5KV-800KVA
SCB-10.5KV-630KVA
Basic info
Brand Vziman
Model NO. 10.5KV Silicon Steel Dry Type Distribution Transformer 630KVA/800KVA/1000KVA/1250KVA /1600KVA/2000KVA
Rated capacity 2000kVA
Voltage grade 10.5KV
Series SCB
Product Detail

Feature:

  •  The magnetic core has a miter step joint to ensure optimum performance and minimum sound levels by using step lap technology.

  •  Windings are cast under vacuum with epoxy resin. Transient analysis tests have been performed to verify the electrical stress distribution.

  • Air-cooling system adopts top-blowing cross flow fan, which has the characteristics of low noise, high wind pressure, beautiful look, etc.

  •  Intelligent temperature controller improves the safety and reliability of the transformer.

  • Supply various Enclosure options in IP20, IP23, etc.


Parameter:

image.png


Installation Location:


  • Installed in places without fire, explosion hazard, serious pollution, chemical corrosion and cluster vibration, indoor or outdoor.

  • Supply Ability 500 Set/Sets per Month.

Customized Service:

  • E2 Environmental Class

  • C2 Climate Class

  • F1 Fire Resistance Class


Product Advantages:

  •  Vacuum-Casting

    Our product is manufactured with vacuum casting process using a metal pattern, producing a thick resin layer with a smooth surface.

  •  Partial Discharge Free

  • Lower partial discharge characteristics.

  • All units are subjected to partial discharge test.

  • Voltage that is twice that of the operating system is applied to ensure safety.

  • Partial discharge is less than 10 pC.

  •  Shop Test Items

Routine test:

  • Routine test is a must test for all transformers in our workshop.

  • Type test (as requested).

  • Lightning impulse test.

  • Temperature-rise test.

  • Measurement of sound level.


How does the current in the primary winding create an alternating magnetic field in the core?


Relationship between Current and Magnetic Field:

When a current passes through a conductor, a magnetic field will be generated around the conductor. For a transformer, the current in the primary winding will generate a magnetic field in the iron core. The specific steps are as follows:

The current passes through the primary winding:

  • AC power supply: The primary windings of the transformer are connected to the AC power source, and the current provided by the AC power source is alternating, i.e., the direction and magnitude of the current periodically change with time.

  • Current waveform: Assuming that the current waveform of the AC power supply is a sine wave, it can be expressed mathematically as I(t)=I0sin(ωt)  ,whereI0  is the maximum value of the current,ω is the angular frequency,t is time.

 Generation of magnetic field:

  • Generation of magnetic field: When the alternating current passes through the primary winding, a magnetic field will be generated around the winding. According to Ampère's circuital law, the magnetic field strength 
    B  generated by the current in a closed loop is proportional to the current.

  • Direction of magnetic field: The direction of the magnetic field can be determined by the right - hand rule. Point the thumb of the right hand in the direction of the current, and the direction in which the four fingers curl is the direction of the magnetic field.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!