0 to 500Hz 200V to 690V engineering frequency converter

  • 0 to 500Hz 200V to 690V engineering frequency converter

Key attributes

Brand RW Energy
Model NO. 0 to 500Hz 200V to 690V engineering frequency converter
Rated frequency 50/60Hz
Series HV500

Product descriptions from the supplier

Description

Overview

HV500 series is an engineering single frequency converter with three product concepts: "universal", "easy to use" and "durable" for mid-to-high-end industrial single transmission applications on the basis of inheriting the excellent control performance of HD2000 engineering frequency converters. It can be widely used in metallurgy, nonferrous metals, chemicals, electric power, rubber, cement, lifting, papermaking, mining, textile and municipal industrial occasions.

Performance characteristics

Durability

  • Mechanical vibration level 3M3

  • Independent air duct design

  • Automatic spraying of conformal paint

  • Built-in dynamic junction temperature model to help product safety application

Versatility

  • Certified by a number of international standards and compliant with RoHS Directive

  • Support V/F, OLVC, CLVC control

  • Support multiple communication protocols

  • Support asynchronous and permanent magnet synchronous motors

Ease of use

  • Supports external 24V DC input power supply

  • Built-in brake unit can be used to save installation controls

  • Book-type design supports seamless side-by-side installation

Meet a variety of needs

  • LCD display panel as standard to improve user experience

  • With master-slave control function

  • Expandable communication card, code disk card, voltage detection card

Excellent performance

  • Zero-speed hover

  • Torque response of 1-3ms

  • Excellent robustness

  • Very low dynamic drop and dynamic drop equivalent

  • Accurate off-line/in-line motor model recognition

Quick debugging software in the background

  • Powerful and easy to use

  • Features such as parameter setting, real-time oscilloscope, fault recording, and event recording

Main parameters

project

Specifications and technical data

Power input and output

Input voltage Uin

200V (-15%) ~ 240V (+10%) three-phase, 380V (-15%)~480V (+10%) three-phase, 500V (-15%)~690V (+10%) three-phase

Input power frequency

50Hz/60Hz±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0Hz~500Hz

Power range

2.2kW~560kW

Mainly control performance

Motor type

Asynchronous motor/synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:10  V/F; 1:100  OLVC; 1:1000  CLVC

Start torque

VF:100%(0.5Hz);OLVC:150%(0.5Hz);CLVC:180%(0Hz)

Torque accuracy

≤5%, under vector control mode

Torque pulsation

≤5%, under vector control mode

Steady speed accuracy

OLVC 0.2%; CLVC 0.01%

Torque response

<5ms, under vector control

Dynamic drop equivalent

OLVC<0.5%*s; CLVC<0.3%*s

Increase and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150% 1min/5min for heavy-duty applications; Light load application 110% 1min/5min

V/F curve

Various methods: linear VF curve, 5 torque reduction characteristic curve methods; (2.0 powers, 1.8 powers, 1.6 powers, 1.4 powers, 1.2 powers)

User-defined VF curves

Input frequency resolution

The digital setting is 0.01Hz, and the analog setting is 0.01Hz

Main control functions

acceleration and deceleration curves

Straight line, S-curve

Multi-speed operation

16 speed operation is achieved through the control terminal

Automatic Voltage Regulation (AVR)

When the grid voltage changes within a certain range, it can automatically keep the output voltage constant

Fixed length control

Given length control

Built-in PID

It can be easily formed as a closed-loop control system

Enhancements

Free function blocks

Input and output functions

Frequency setting method

Keyboard given, UP/DOWN terminal, multi-speed give, terminal pulse given, communication

Analog input terminals

AI1: 0V~10V/-10V~10V; AI2 : 0V~10V/0(4)mA~20mA

Digital input terminals

DI1-DI6, 6 programmable digital inputs, optocoupler-isolated, drain/source compatible inputs

Digital input and output terminals

DIO1: Fast pulse output, normal input/output; DIO2: Fast pulse input, normal input/output

Analog output terminals

2 channels 0V~10V/0(4)mA~20mA

Relay output

2-way contact type FormC

Motor temperature detection

Support type PT100/PT1000/KTY84

STO interface

SIL3/PLe level safety torque shutdown function

communication

Communication protocol

Modbus RTU (standard), Profibus, CANopen, profinet, Devicenet, ControlNet

Usage environment

altitude

no derating is required within 2000 meters above sea level; At an altitude of 2000 meters ~ 4000 meters, the current must be reduced by 1% for every 100 meters of elevation

Ambient temperature

-25°C~+40°C (40°C to 55°C derating is allowed)

humidity

15%~95%, no condensation

vibration

3M3,IEC60721-3-3

Storage temperature

-40℃~+70℃

Place of use

Indoors, there is no direct sunlight, no flammable and corrosive gases, liquids and conductive particles

Options:

code disk card, communication expansion card, voltage detection card

Protection function

Short circuit, overcurrent, overload, overvoltage, undervoltage, phase loss, overheating, external faults, etc

efficiency

5.5kW~22kW:≥93%; 30kW and above: ≥95%

Installation method:

Loading machines and containers

Protection level

IP20

Cooling method

Forced wind cooling

Documentation Resource Library
Restricted
HV500 High-Performance VFD selection catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: Can multiple motors be synchronized?
A:

Supports master-slave synchronous control, allowing multiple motors to start and stop simultaneously. The rollers on the production line run synchronously without jamming. It also supports switching between 4 sets of motor parameters, allowing one frequency converter to handle multiple devices, saving space and money.

Q: Can it automatically recover after a power outage?
A:

There is a power outage restart function! After a power outage, the power grid will automatically resume stable operation without manual intervention. The factory experiences power outages at night and automatically starts working as soon as the power is restored in the morning, saving labor and increasing efficiency, ensuring uninterrupted production.

Q: How high is the control accuracy?
A:

Under closed-loop vector control, the stable speed accuracy is 0.01% (CLVC), which is 10 times higher than that of ordinary frequency converters. The conveyor belt runs super smoothly, and the products will not fall off. The precision is as high as in a laboratory, and the production quality is more stable.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.