Diversity Factor

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is Diversity Factor

We can not store electricity. Thus we have to generate electricity when it is required and as much it is required. The electrical source either it is generating station or substation or any other electric utility, has to fulfil the maximum demand of all connected loads to that source. But we are fortunate enough that the maximum demands of all the loads connected to a source usually do not happen simultaneously. Instead, maximum loading demands of various loads occur at different period of times in a day. Because of this typicality of electrical load, we can construct a comparatively smaller source of electricity to fulfil a significant number of consumers or loads.

Here the term diversity factor comes into the picture. We define the diversity factor of an electrical system as the ratio of the sum of maximum demands of individual loads connected to the system to the simultaneous maximum demand of the system itself. We can understand better if we give a practical example of diversity factor. The maximum simultaneous load on the substation cannot be more or even equal to the sum of the maximum demand of individual loads as these maximum demands of individual load do not occur concurrently at the same time.

Let us consider an electrical substation. We can categorise the loads connected to that substation as domestic loads, commercial loads, industrial loads, municipal loads, irrigation loads and traction loads.

  • Domestic loads consist of light, fans, refrigerators, heaters, televisions, air conditioners water pumps etc. The maximum demand for residential loads or domestic loads occurs typically at evening.

  • Commercial loads consist of the lighting of shops and electrical appliances used in stores and restaurants. The consumption of load maximises during the evening as well as the daytime also.

  • Industrial loads consist of heavy industrial machinery.

  • Municipal loads consist of the street lighting system, water pumping system in water pumping stations. The consumption of these loads is not also consistent throughout 24 hours.

  • Irrigation consumes power during daytime only.

  • Traction loads become maximum during starting and ending of office hours just.

So we now understand that the maximum demands of all loads connected to a substation do not coincide. Instead, they occur in different periods during a 24-hour span. Because of this diversity of electrical loads, we can construct comparatively lower capacity substation or a similar utility for larger connected loads.
Let us name an electrical substation as X. A, B, C and E are downstream substations connected to the substation X. The maximum demand of these substations is A megawatts, B megawatts, C megawatts D megawatt, and E megawatt respectively. The simultaneous maximum demand of the X substation is X megawatt. The diversity factor substitution would beIt is needless to say that the value of diversity factor must be greater than unity. It is always desirable to have diversity factor as bigger as possible, to facilitate the commercial viability electricity utility business.

Now you are going to show you one practical example of diversity factor. A power transformer is connected to the following loads. The industrial load is 1500 kW, the domestic load is 100 kW and the municipal load is 50 kW. The maximum demand for the power transformer is 1000 kW. The diversity factor of the transformer would be

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.