What is Transformer Acidity Test?

Encyclopedia
Field: Encyclopedia
0
China

What is Transformer Acidity Test?

Acidity Test Definition

The acidity test of transformer oil measures the amount of potassium hydroxide (KOH) needed to neutralize the acid in the oil.

38a81b543327bb973217e51a683446b1.jpeg 

Causes of Acidity

Acidity occurs due to oxidation, especially when oil contacts air, and is accelerated by heat and metals like iron and copper.

Effects of Acidity

Higher acidity lowers oil resistivity, increases the dissipation factor, and can harm transformer insulation.

Acidity Test Kit Components

We can determine the acidity of transformer insulating oil, by a simple portable acidity test kit. It consists of one polythene bottle of rectified spirit (ethyl alcohol), one polythene bottle of sodium carbonate solution and one bottle of universal indicator (liquid). It also consists of clear and transparent test tubes and volumetrically scaled syringes.

08d520e9c1918e1250daa5a76880a6db.jpeg

 Principle of Acidity Test of Insulating Oil

 Adding alkali to the oil changes its acidity based on the acid amount present. If the alkali added equals the acid present, the oil’s pH will be 7 (neutral). More alkali makes the oil alkaline (pH 8-14), while less makes it acidic (pH 0-6). The universal indicator shows different colors for different pH levels, allowing us to visually determine the oil’s acidity.

Acidity of Insulating Oil Measure

The acidity of insulating oil is measured by the amount of KOH (in milligrams) needed to neutralize the acid in a specific amount of oil (in grams). For example, if the oil has an acidity of 0.3 mg KOH/g, it means 0.3 milligrams of KOH is needed to neutralize 1 gram of the oil.

Testing Procedure

The procedure involves adding specific amounts of rectified spirit, sodium carbonate, and a universal indicator to the oil and observing the color change to determine acidity. 

563b1c26783946c309ba1bea5f5fe8c5.jpeg


Give a tip and encourage the author!
Recommended
Strange Devices on Transmission Lines: 5 Little-Known Practical Functions(1)
1 Aviation Warning SpheresAviation warning spheres, also known as reflective safety spheres, are used on overhead transmission lines near airports, especially on extra-high-voltage (above 220kV) lines and river-crossing transmission lines. Highly visible aviation marker spheres (aviation warning spheres) must be installed along the lines to provide warning signals.The aviation marker sphere (aviation warning sphere) has a diameter of ф=600mm. The sphere can be manufactured in various bright colo
Leon
09/04/2025
Transmission Line
In transmission lines, a "π" connection involves breaking the original line from Substation A to Substation B and inserting Substation C, forming a "π" configuration. After the "π" connection, the original single line is divided into two independent transmission lines. Following the "π" connection, Substations B and C may both be powered by Substation A (in this case, Substation C receives power via a feeder from Substation B's busbar, or possibly from another voltage point within Substation B);
Encyclopedia
09/04/2025
What are the principles of forced re-energization of transmission lines?
Principles of Forced Re-energization of Transmission LinesRegulations for Forced Re-energization of Transmission Lines Correctly select the forced re-energization end of the line. If necessary, change the connection configuration before forced re-energization, taking into account the reduction of short-circuit capacity and its impact on grid stability. There must be a transformer with its neutral point directly grounded on the busbar at the forced re-energization end. Pay attention to the impact
Edwiin
09/04/2025
Analysis of Accident Handling in Transmission Lines
Analysis of Transmission Line Fault HandlingAs a fundamental component of the power grid, transmission lines are widely distributed and numerous, often exposed to diverse geographical and climatic conditions, making them highly susceptible to faults. Common causes include overvoltage, pollution flashover, insulation damage, tree encroachment, and external damage. Line tripping is one of the most frequent faults in power plant and substation operations, with fault types including single-phase-to-
Leon
09/04/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.