What happens when there is an electric shock in a neutral wire?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Principles of electric shock

In a normal three-phase four-wire power supply system, the neutral wire (PEN wire or N wire) is grounded. Theoretically, the potential of the neutral wire is the same as that of the earth. When the three-phase load is balanced, there is almost no current flowing through the neutral wire. However, when a person touches the neutral wire and there is a fault in the neutral wire, an electric shock accident may occur.

Electric shock mainly occurs because there is current flowing through the human body. The degree of harm caused by electric shock to the human body is related to factors such as the magnitude and duration of the current passing through the human body and the path of the current. Generally, it is considered that when the power frequency current (50Hz or 60Hz) passing through the human body exceeds 10mA, it may make it impossible for a person to get rid of the power supply independently. When the current exceeds 30mA, it may lead to serious consequences such as cardiac fibrillation.

Neutral wire fault conditions that may lead to electric shock

Neutral wire breakage

When the neutral wire is broken, in the case of three-phase imbalance, the potential of the neutral wire after the break point will shift. For example, in a lighting circuit with three-phase four-wire system, if the neutral wire is broken at a certain place, due to the fact that the loads of each phase (such as lamps) cannot be completely the same, the current that originally returned to the power supply through the neutral wire cannot flow normally. At this time, taking the phase with more loads as an example, part of the current of this phase will form a loop through the loads and neutral wires of other phases, making the potential of the neutral wire no longer zero and may rise to a higher voltage. If a person touches this live neutral wire at this time, there will be current passing through the human body, resulting in electric shock.

Poor neutral wire contact

Poor contact at the connection point of the neutral wire and the equipment or at the neutral wire terminal in the distribution box is also very common. Poor contact will cause the resistance at this point to increase. According to Ohm's law U=IR , when there is current passing through, a voltage drop will occur at the point of poor contact. If this voltage drop is large enough to make the potential of the neutral wire deviate from the earth potential, when a person touches it, there will be current passing through and cause electric shock.

Neutral wire and phase wire short-circuit and then ground fault (a more complex situation):

This situation may cause the neutral wire to have a dangerous voltage. For example, inside an electrical equipment, a short circuit occurs between the neutral wire and the phase wire. The large current after the short circuit may cause the protection device to act. However, if the fault does not completely cut off the circuit, or due to the imperfect grounding system, a part of the short-circuit current will flow into the earth through the grounding device. At this time, the neutral wire may have a certain residual voltage. When a person touches the neutral wire, they will get an electric shock.

Manifestations of harm from electric shock

Electric shock injury

When current passes through the human body, it will cause direct electric shock damage to important organs such as the nervous system and heart. The human body will feel a tingling sensation. As the current increases, this feeling will become stronger and muscle spasms may occur. If the current lasts for a long time or the current is large, it will lead to respiratory paralysis and cardiac arrest. For example, when the current passing through the human body reaches several tens of milliamperes or more, it may cause ventricular fibrillation, which is a very dangerous arrhythmia that will make the heart unable to pump blood effectively and endanger life.

Electric burn

At the same time as a person gets an electric shock by touching the neutral wire, if an arc is generated at the contact point or the current generates heat inside the human body, an electric burn will occur. The degree of electric burn is related to factors such as the magnitude of the current, the contact time, and the human body resistance. Generally speaking, electric shock with high voltage and large current is more likely to cause severe electric burns. Electric burns not only damage the skin but may also cause deep injuries to subcutaneous tissues, muscles, and bones. For example, when a person touches the neutral wire with a relatively high voltage, the contact point may appear charred and carbonized, and the surrounding tissues will also appear redness, blisters and other conditions due to thermal damage.


Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar