Busbars ug Connectors sa HV ug EHV installations

Edwiin
Larangan: Switch sa kuryente
China

Unsa ang Electric Busbar?

Ang electric busbar mao ang konduktor o set sa mga konduktor nga gidesinyado aron mogamit og elektrisidad gikan sa mga incoming feeders ug mobahin kini sa mga outgoing feeders. Sa pagpangita, kini nagserbisyo isip junction diin ang inflowing ug outflowing currents magkonekta, nagsilbi usab isip central hub alang sa power aggregation ug distribution.

Outdoor Busbar Installations

Sa high-voltage (HV), extra-high-voltage (EHV), ug outdoor medium-voltage (MV) systems, ang bare busbars ug connectors kasagaran gigamit, uban ang mga konduktor nga naa sa tubular o stranded-wire configurations:

  • Tubular Busbars: Gisuportahan niini ang column insulators (kasagaran ceramic), kini naghatag og mataas nga mechanical strength ug superior corona resistance.

  • Stranded-Wire Busbars: Giseguro niini pinaagi sa dead-end clamps, ideal para sa mga installations nga gibutangan sa large-span flexibility.

(Ang mga examples sa susamang configurations gitumong sa Figures 1 ug 2.)

Busbars for Switchgear Installations

Ang switchgear busbars kasagaran gihimo gikan sa copper, aluminum, o aluminum alloys (e.g., Al-Mg-Si series), uban ang key characteristics sa bare busbars kasagaran adunay:

  • Geometric Parameters

    • Tubular conductors: Outer diameter ug wall thickness

    • Stranded wires: Nominal cross-sectional area

  • Mechanical Properties

    • Tensile/compressive/bending strength

    • Buckling resistance

    • Section modulus ug moment of inertia

  • Current-Carrying Capacity

    • Rated current: Determindahan niini gikan sa material resistivity ug heat dissipation conditions.Pasabot ang bare conductors gidepende sa air insulation, ang rated voltage dili primary selection criterion.

Busbar Connection Technology

Ang dedicated connectors importante aron termihin ang busbars sa equipment, gitumong niini sa Figure 3. Ang typical configurations kasagaran adunay:

  • Bolted connections: Rigid joints secured by torque-controlled bolts, requiring contact resistance management to prevent overheating

  • Expansion joints: Compensate for thermal expansion, mitigating structural stress concentrations

  • Transition terminals: Address electrochemical corrosion between dissimilar materials (e.g., copper-aluminum interfaces)

Ang connection design dili bayad mahimong komplyante sa:

  • Contact area standards for temperature rise (e.g., IEC 61439)

  • Material compatibility treatments (e.g., tin-plating for copper-aluminum transitions)

  • Mechanical stability under short-circuit electro-dynamic forces

Engineering Considerations

Ang medium/high-voltage switchgear busbar systems nagkinahanglan og integrated design para sa:

  • Thermal management: Optimized air convection or forced cooling to control temperature rise

  • Dynamic stability: Structural integrity under short-circuit electrodynamic forces

  • Environmental protection: IP3X or higher ingress protection matching operational environments

Kini nga mga measures collectively ensure reliable power transmission and extended equipment service life.

Widely used in data centers and industrial plants for high-current power distribution, these systems enable flexible layout and easy expansion through modular design.
For copper-copper connections, bronze connectors are used; for aluminium-aluminium connections, aluminium alloy connectors should be applied; and for copper-aluminium connections, bi-metallic connectors are mandatory to prevent corrosion caused by electrolytic effects.
Insulated Busbars & Trunking Systems
In indoor medium-voltage (MV) and low-voltage (LV) installations—particularly where high currents and limited space coexist—busbars are often enclosed in metallic casings for mechanical protection and insulation.This design reduces busbar heat dissipation due to restricted air flow and radiation losses, resulting in current ratings significantly lower than those for free-air installations. Ventilated enclosures can be used to minimize current derating.

Technical Details Analysis

  • Electrochemical Protection for Different Material Connections

    • Copper-copper joints: Bronze connectors (tin bronze or aluminium bronze) enhance contact reliability via solid solution strengthening, preventing pure copper creep relaxation.

    • Aluminium-aluminium joints: 6061-T6 aluminium alloy connectors undergo aging treatment to ensure oxide film stability.

    • Copper-aluminium transitions: Bi-metallic connectors use explosive welding or brazing (e.g., copper-aluminium composite bars) to block electrochemical corrosion paths.

  • Thermal Management Challenges in Enclosed Busbars
    Thermal resistance analysis: Air gaps formed by enclosures reduce thermal conductivity by 30%-50%.
    Compensation solutions:

    • Forced air cooling: Internal fans increase current-carrying capacity by 20%-30%.

    • Enclosure cooling fins: Enhanced surface area for natural convection.

    • High thermal conductivity insulation: Silicone rubber coatings to reduce thermal resistance.

  • Engineering Application Specifications

    • Protection class: Typically IP54 for indoor environments, upgraded to IP65 in humid conditions.

    • Short-circuit withstand: Compliant with IEC 61439 dynamic and thermal stability requirements.

    • Expansion compensation: Expansion joints every 30-50 meters to accommodate thermal deformation.

Widely used in data centers and industrial plants for high-current power distribution, these systems enable flexible layout and easy expansion through modular design.

Isolated Busbars

Isolated busbars typically consist of copper or aluminium flat bars (one or more per phase, sized according to current requirements), with each phase enclosed in a separately earthed sheath. The sheath ends are connected by short-circuit rated bars capable of carrying full fault currents.The sheath primarily prevents inter-phase short circuits. Additionally, it cancels out magnetic fields generated by conductor currents: an equal and opposite current induced in the sheath neutralizes the electromagnetic field almost completely.Common insulating media include air and SF₆.

LV Busbar Trunking Systems

In low-voltage installations, busbar trunking systems offer a cost-effective solution for power distribution, supplying multiple devices and interconnecting switchboards or transformers, as shown in Figure 5.

Busbar Trunking Systems

A busbar trunking system is a pre-assembled configuration housing flat-bar conductors (phase and neutral) within a single metallic enclosure.In feeder trunking systems, power tap-off is achieved via standardized tap-off units, which connect at predefined positions along the trunking. These units enable power extraction through compatible protective devices.

Advantages Over Cable Systems:

  • Cost-Effectiveness & Installation Efficiency

    • More economical for high-current applications: Eliminates the need for parallel single-core cables to meet current ratings, voltage drop, and dip requirements.

    • Reduces overheating risks: Avoids heat buildup in cable bundles that can lead to short circuits.

  • Mechanical Superiority

    • Long-span stability: Requires minimal fixings, reducing installation time.

    • Eliminates cable support structures: Minimizes metalwork requirements.

  • Space & Maintenance Benefits

    • Accommodates post-installation power changes (within trunking ratings).

    • Enables easy repositioning of distribution points.

    • Facilitates system expansion.

    • Reduces switchboard termination space.

    • Eliminates cable joints: Lowers contact resistance and failure points.

    • Flexible tap-off design:

  • Additional Advantages

    • Aesthetic appeal in visible areas.

    • Reusability: Can be dismantled and relocated.

    • Enhanced fire resistance: Metal enclosures contain fire spread.

Maghatag og tip ug pagsalig sa author

Gipareserbado

Pangunahon nga Transformer Accidents ug Light Gas Operation Issues
1. Talaan sa Pagkamalasakit (Marso 19, 2019)Sa 16:13 sa Marso 19, 2019, ang background monitoring nagreport og light gas action sa No. 3 main transformer. Sumala sa Code for Operation of Power Transformers (DL/T572-2010), ang mga tawo sa operation and maintenance (O&M) nagsagol sa kondisyon sa No. 3 main transformer sa dapit.Konfirmasyon sa dapit: Ang WBH non-electrical protection panel sa No. 3 main transformer nagreport og Phase B light gas action sa transformer body, ug ang reset wala mae
02/05/2026
Mga Sayop ug Paghunahuna Sa Pag-atas Sa Iisa Ka Fasa Sa 10kV Distribution Lines
Mga Kinaiya ug mga Kaugalingong Detektor sa Single-Phase Ground Fault1. Mga Kinaiya sa Single-Phase Ground FaultMga Signal sa Central Alarm:Nagring ang warning bell, ug naglitaw ang indicator lamp nga gilabel “Ground Fault on [X] kV Bus Section [Y]”. Sa mga sistema nga may Petersen coil (arc suppression coil) nga naka-ground sa neutral point, ang “Petersen Coil Operated” nga indicator usab motindog.Mga Indikasyon sa Insulation Monitoring Voltmeter:Ang voltage sa nahisalaan nga phase mokubos (kon
01/30/2026
Neutral nga punto sa grounding operation mode alang sa 110kV~220kV power grid transformers
Ang pag-arrange sa mga modo ng operasyon ng grounding ng neutral point para sa 110kV~220kV power grid transformers dapat matugunan ang mga requirement ng insulation withstand sa mga neutral points ng transformer, ug usahay mao usab ang pagpanalipod sa zero-sequence impedance sa mga substation nga walay dako nga kausaban, samtang sigurado nga ang zero-sequence comprehensive impedance sa anumang punto sa short-circuit sa sistema dili mogawas sa tulo ka beses sa positive-sequence comprehensive impe
01/29/2026
Unsa ang Katuyohan sa Paggamit og Bato Gravel Pebbles ug Crushed Rock sa mga Substation?
Asa Kini ang mga Substation Usa ka Bato, Gravel, Pebbles, ug Crushed Rock?Sa mga substation, ang mga equipment sama sa power ug distribution transformers, transmission lines, voltage transformers, current transformers, ug disconnect switches nimo kinahanglan og grounding. Padulong sa grounding, karon atong ibutangan ang kahibawo bahin kon asa kini nga gravel ug crushed stone gamiton sa mga substation. Bisag ordinaryohan ra sila, importante kaayo ang papel nila sa seguridad ug pagkabana-bana.Sa d
01/29/2026
Inquiry
+86
I-klik aron i-upload ang file
Pangutana
Pangutana sa IEE-Business Application
Pangita og mga equipment gamit ang IEE-Business app asa asa ug kailan man sugad og pagkuha og solusyon pagsulay sa mga eksperto ug pagpadayon sa industriya nga pakisayran suportahan ang imong proyekto sa kuryente ug negosyo