The primary side of the transformer is energized, and the secondary side does not distribute power, what faults may occur in the transformer?

Encyclopedia
10/22/2024

If the primary side of the transformer is powered, and the secondary/distribution side does not distribute power, even if the fuse is in normal condition, then the following faults may occur in the installed transformer:

  1. Winding Failure: The secondary winding may be open, resulting in no voltage output on the secondary side.

  2. Wiring Errors: During installation, there may be incorrect connections between the primary and secondary windings.

  3. Internal Short Circuit: Although the fuse is normal, there may be a local short circuit inside, causing the secondary side to not work properly.

  4. Core Failure: The core may have issues such as looseness or poor insulation, affecting the normal transmission of magnetic flux.

  5. Switch or Contactor Failure: The switch or contactor on the secondary side may not be closed or there may be poor contact, preventing power from being distributed.

To accurately diagnose the problem, it is recommended to perform detailed inspections and tests, including measuring the resistance of primary and secondary windings, checking the wiring, testing the condition of the core, and confirming the status of all switches and contactors.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co